Page 11
SECTION 1
Introduction
Programming Use any of the following to program M90: "
Microsoft C 4.0 or later
Borland C 3.0 or later " TURBO PASCAL 6.0 or later " IBM PC macro assembler version 1.0 or later The downloaded application program determines the intelliĆ gence level of the M90. Once started, the M90 operates as a standĆalone unit or can be combined with a host or perĆ sonal computer. "
Sufficient energy stays in the main or backup battery to reĆ tain the program and data even when the power is down. Transaction data transfers to the computer or stays in the M90 RAM area.
Application Program Interface The M90 Kernel includes three basic modules: device drivĆ er, file manager, and DOS manager. The programmer can design the application programs by calling those functions just like in a PC DOS environment. The programs are in the .EXE format. For endĆusers who use the C/PASCAL compiler and assemĆ bler, the ROMĆbased hardware of the M90 provides emuĆ lated MS-DOS function calls. The calling and parameter passing conventions are identical with MS-DOS. Table 1-1 describes several subsystems and related I/O interface funcĆ tions, and the DOS and file manager functions. " NOTE:
For the detailed calling process, see Section 4.
M90 Series Portable Data Entry Unit Reference Manual
1-3
Page 12
Introduction
SECTION 1
Keypad Subsystem The keypad subsystem scans the key matrix, converts the scan code to its associated key value, and stores the value in the input buffer of the keyboard. Table 1-1 indicates the scan code and its default key ASCII value and display of each key on the keypad. " NOTE:
Table 1-1 lists the keys from left to right, from the upper left corner of the M90 keypad. Default ASCII values are from the English keypad. Table 1-2, on page 1-10, contains ASCII values that differ on Swedish, Finnish, Danish, Spanish, French, German, and Italian keypad subsystems. Table 1-1 English Keypad Subsystem
Shift
Key
Hex Value
ASCII Character
[ENT SCAN] 0D
<CR>
[S1]
[ENT SCAN] 0D
<CR>
[S2]
[ENT SCAN] 0D
<CR>
[S3]
[ENT SCAN] 0D
<CR>
[FN]
[ENT SCAN] 0D
<CR>
[S1]
00
[S1]
[S1]
00
[S2]
[S1]
00
[S3]
[S1]
00
[FN]
[S1]
00
[S2]
00
[S1]
[S2]
00
[S2]
[S2]
00
[S3]
[S2]
00
[FN]
[S2]
00
1-4
M90 Series Portable Data Entry Unit Reference Manual
Page 13
SECTION 1
Introduction
Table 1-1 (Continued) English Keypad Subsystem Shift
Key
Hex Value
ASCII Character
[S3]
00
[S1]
[S3]
00
[S2]
[S3]
00
[S3]
[S3]
00
[FN]
[S3]
00
[FN]
00
[S1]
[FN]
00
[S2]
[FN]
00
[S3]
[FN]
00
[FN]
[FN]
00
[7]
37
[S1]
[7]
41
[S2]
[7]
42
[S3]
[7]
43
[FN]
[7]
00
[8]
38
[S1]
[8]
44
[S2]
[8]
45
[S3]
[8]
46
[FN]
[8]
00
[9]
39
[S1]
[9]
47
[S2]
[9]
48
[S3]
[9]
49
[FN]
[9]
00
M90 Series Portable Data Entry Unit Reference Manual
1-5
Page 14
Introduction
SECTION 1
Table 1-1 (Continued) English Keypad Subsystem Shift
Key
Hex Value
ASCII Character
[4]
34
[S1]
[4]
4A
[S2]
[4]
4B
[S3]
[4]
4C
[FN]
[4]
00
[5]
35
[S1]
[5]
4D
[S2]
[5]
4E
[S3]
[5]
4F
[FN]
[5]
00
[6]
36
[S1]
[6]
50
[S2]
[6]
51
[S3]
[6]
52
[FN]
[6]
00
[1]
31
[S1]
[1]
53
[S2]
[1]
54
[S3]
[1]
55
[FN]
[1]
00
[2]
32
[S1]
[2]
56
[S2]
[2]
57
[S3]
[2]
58
[FN]
[2]
00
1-6
M90 Series Portable Data Entry Unit Reference Manual
Page 15
SECTION 1
Introduction
Table 1-1 (Continued) English Keypad Subsystem Shift
Key
Hex Value
ASCII Character
[3]
33
[S1]
[3]
59
[S2]
[3]
5A
[S3]
[3]
20
Space
[FN]
[3]
00
[DEL]
08
BS
[S1]
[DEL]
08
BS ***** (See footer page 1-9)
[S2]
[DEL]
08
BS ***** (See footer page 1-9)
[S3]
[DEL]
08
BS ***** (See footer page 1-9)
[FN]
[DEL]
08
BS
[0]
30
[S1]
[0]
2A
[S2]
[0]
2B
[S3]
[0]
2C
[FN]
[0]
00
[.]
2E
[S1]
[.]
2F
[S2]
[.]
3A
[S3]
[.]
3D
[FN]
[.]
00
A
11
[S1]
A
11
[S2]
A
11
[S3]
A
11
[FN]
A
* (See footer page 1-9)
M90 Series Portable Data Entry Unit Reference Manual
1-7
Page 16
Introduction
SECTION 1
Table 1-1 (Continued) English Keypad Subsystem Shift
Key
Hex Value
B
12
[S1]
B
12
[S2]
B
12
[S3]
B
12
[FN]
B
ASCII Character
** (See footer page 1-9)
Y
13
[S1]
Y
13
[S2]
Y
13
[S3]
Y
12
[FN]
Y
*** (See footer page 1-9)
"
10
[S1]
"
10
[S2]
"
10
[S3]
"
10
[FN]
"
84
**** (See footer page 1-9)
[F1]
86
[S1]
[F1]
86
[S2]
[F1]
86
[S3]
[F1]
86
[FN]
[F1]
8A
[F2]
87
[S1]
[F2]
87
[S2]
[F2]
87
[S3]
[F2]
87
[FN]
[F2]
8B
1-8
M90 Series Portable Data Entry Unit Reference Manual
Page 17
SECTION 1
Introduction
Table 1-1 (Continued) English Keypad Subsystem Shift
Key
Hex Value
ASCII Character
[F3]
88
[S1]
[F3]
88
[S2]
[F3]
88
[S3]
[F3]
88
[FN]
[F3]
8C
[F4]
89
[S1]
[F4]
89
[S2]
[F4]
89
[S3]
[F4]
89
[FN]
[F4]
8D
* ** *** ****
*****
The [FN], A key combination turns the backlight on and off. The [FN], B key combination adjusts the contrast. The [FN], Y key combination adjusts the speaker volume. The [FN], " key combination activates the “User Menu” when the M90 is in “Ready Mode.” When the M90 is in the “User Menu,” the key combination takes you back to “Ready Mode.” When [FN] and " are pressed simultaneously pressed, M90 performs a WARM START. Table 1-2, on the next page, has other values for non-English subsystems.
M90 Series Portable Data Entry Unit Reference Manual
1-9
Page 18
Introduction
SECTION 1
Table 1-2 Non-English Keypad Subsystems Shift
Key
Language
Hex Value
ASCII Character
[S1]
[DEL]
Swedish
8F
Finnish
8F
Danish
92
Spanish
AD
French
F8
German
8E
Italian
F9
Swedish
8E
Finnish
8E
Danish
9D
Spanish
A5
French
87
German
99
Italian
5C
Swedish
99
Finnish
99
Danish
8F
Spanish
A8
French
26
German
9A
Italian
82
[S2]
[S3]
1-10
[DEL]
[DEL]
M90 Series Portable Data Entry Unit Reference Manual
Page 19
SECTION 1
Introduction
Shift Keys S1 0000: 1B7E S2 0000: 1B7F S3 0000: 1B80 Value:
0 Not in shift mode. 255 In shift mode.
Key in Keyboard Buffer 0000:1BAF Value: 0 1
Buffer is not empty. Buffer is empty.
File System Directory address:
0000:3A64 Table 1-3 File System
Filename Address
Contents
0
Name
16
Start address
18
Low word of size
20
High word of size
26
Used or not used, zero is not used
32
Next name
M90 Series Portable Data Entry Unit Reference Manual
1-11
Page 20
Introduction
SECTION 1
Display Subsystem The M90 Display Subsystem supports a characterĆoriented 8Ćline by 16Ćcharacter or 4Ćline by 12Ćcharacter display with backlight control. The origin (0,0) is always at the upper leftĆhand corner.
Real-Time Clock Subsystem The realĆtime clock subsystem keeps system time and date values for the M90. The subsystem also provides the alarm or wakeĆup functions.
Serial Port Subsystem The M90 has an RS-232 Serial Port for data communicaĆ tion. Its communication system consists of pointĆtoĆpoint connection type for general processing. The operator may press the [FN] key, then the " key to enter Mode," then select COM to invoke the builtĆin Kermit server for pointĆtoĆpoint communication. The RI signal of the port can turn on the M90.
Bar Code Input Port There is one bar code input port plus an integrated bar code scanner on the M90. The bar code port is for bar code scanĆ ning devices such as bar code wand, wandĆemulation CCD, or laserĆdiode scanners. Depending on its connection, the scanner may turn the unit on by scanning without pressing the ON or OFF keys. 1-12
M90 Series Portable Data Entry Unit Reference Manual