The text of a manual · part 7 of 16
M90 Series Portable Data Entry Unit Reference Manual, pages 61 to 70
Pages 61 to 70 of 156
The original document is the PDF (352 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec M90
Page 61
SECTION 3
Operation Modes
The following prompt appears when the programming is ready: < PROGRAMMING Delete program in RAM Disk ?_ 1=YES/0=NO
>
Press [1] to erase the program from the RAM disk, press [0] otherwise. The last screen appears with the change in flash size: < PROGRAMMING Done ! 116KB FLASH Free Press any key.._
>
KB" is an example if the file added was 11 KB. Press any key to return to the menu. Delete All
Press [2] to remove all programs on the FLASH disk. The following verification screen appears: Delete all PROGs in FLASH memory! Continue ?_ 1=YES/0=NO
Press [1] to delete all programs stored on the FLASH disk, press [0] to return to the menu without deĆ leting the programs. If you pressed [1], the following verification screen appears. Press [1] to confirm. < PROGRAMMING
>
Are you sure? 1=YES/0=NO
M90 Series Portable Data Entry Unit Reference Manual
3-31
Page 62
Operation Modes
SECTION 3
Two additional screens appear, the first will show ing," the second displays the flash size after the programs have been erased: < PROGRAMMING Done ! 127KB FLASH Free Press any key.._
>
Press any key to return to the menu. Update BIOS " NOTE:
Before you can update the BIOS, you must download a BIOS file onto the RAM disk. If there is no BIOS file, the update will fail and the M90 will perform a cold start.
Press [3] to update the BIOS. The following verification screen appears: Erase all data in RAM & FLASH ! Continue ?_ 1=YES/0=NO
Press [1] to continue, or press [0] to return to the Initialization" menu. If you pressed [1] to erase all data, the following verificaĆ tion screen appears: < PROGRAMMING
>
Are you sure? 1=YES/0=NO
Press [1] to verify and the M90 updates the BIOS. will appear briefly.
3-32
M90 Series Portable Data Entry Unit Reference Manual
Page 63
SECTION 3
Operation Modes
If a BIOS file is not found on the RAM disk, the following message appears: < PROGRAMMING Please download BIOS file . . . .
>
If you see this message, turn off the M90, then cold start it or wait for the Menu" to cold start the unit. Set up the communications parameters and download the BIOS to the RAM disk. When done, return to the menu. If BIOS is present on the RAM disk, you will see the followĆ ing. Press [1] to change the BIOS. The M90 displays a message, then an message. < PROGRAMMING Change BIOS to VX.XX ? 1=YES/0=NO
>
After the message, a status screen appears with the address count. counts from to < PROGRAMMING Updating BIOS ADDR=XXXXXX
>
After the count is complete, the final screen appears. Press any key to restart the M90. < PROGRAMMING BIOS Update OK! Press Any Key to Restart. . .
>
M90 Series Portable Data Entry Unit Reference Manual
3-33
Page 64
Operation Modes
SECTION 3
System Diagnostic Select option from the Mode" menu to access the M90 diagnostic program to verify the M90. The diagnostic routines run these tests: RAM, keypad, RS-232, LCD, realĆtime clock, scanner, and RAM backup. " NOTE:
Execute this diagnostic program when there is a service process, such as maintenance, repair, or upgrade to verify that system. 0.All 1.RAM 2.KEY 3.232 4.LCD 5.RTC 6.SCANNER 7.RAM BACKUP 8.EXIT SELECT(0 - 8)?_
" NOTE:
The diagnostic program may destroy data. Back up the M90 data.
Run All Seven Tests Select option All" from the menu to run all of the following seven tests. (Requires RS-232 loopback.)
RAM Test Select option from the menu to flush the M90 RAM. The first screen appears with a warning: ! ! WARNING ! ! Will Flush RAM & RAM Disk ! Continue ?_ 1=YES/0=NO
Press [0] to return to the menu, or press [1] to continue with the memory flush. " Fixed pattern stuck at fault check (00, FF, 55, AA) Writes a fixed pattern of data to the RAM chip, then verifies that the data had stored properly. " Address Test: Writes odd, even address data into corresponding memory location, then verifies it. 3-34
M90 Series Portable Data Entry Unit Reference Manual
Page 65
SECTION 3
Operation Modes
Keypad Test Select option from the menu for the Test" screen: KEYPAD TEST Wait key . . .J
Press any key and the ASCII symbol should appear. Press " to exit, and the following prompt appears: KEYPAD TEST Exit_? J 1=YES/0=NO
Press [1] to return to the menu, or press [0] to continue with the keypad test.
RS-232 Loopback Test Select option from the menu for the Test" testing status screen: RS232 TEST Baud= 9600 Baud=19200 Baud=38400 Baud=57600
PASS PASS PASS PASS
Press any key to continue . . . _
A signal is sent from the TXD pin through a loopback conĆ nector to the RXD pin. The received signal is verified to match the transmitted signal. A full ASCII table code (0-255) test pattern should be in each test cycle. CommuĆ nication parameters should equal default values, except the baud rate.
M90 Series Portable Data Entry Unit Reference Manual
3-35
Page 66
Operation Modes
SECTION 3
1 2 3 4 5 6 7 8 9
Figure 3-2 Loopback Connector Wiring
The loopback plug is a 9Ćpin DSUB that can be made to connect either to the M90Ćto-PC communication cable or at the back of the M90 office dock. To connect it to the M90 PC cable, it should be made of a male DSUB. For connection to the M90 office dock, it should be made of a female DSUB. If the loopback test fails, or the test connector is not plugged in, the following screen appears briefly after the testing status screen: RS232 TEST Baud= 9600 Baud=19200 Baud=38400 Baud=57600
FAIL FAIL FAIL FAIL
Press any key to continue . . . _
Press any key to return to the menu.
3-36
M90 Series Portable Data Entry Unit Reference Manual
Page 67
SECTION 3
Operation Modes
LCD Screen Test Select option from the menu for the Test" screen to see graphic patterns on the M90. The patterns start two sets of dark and light screens, followed by two sets of the following: * _
Backlight
ON *
* _
Backlight
OFF
*
The backlight is more noticeable if the M90 is tested in a dimly lit area. After two sets of ON" and light OFF," the final screen appears. Press any key to reĆ turn to the menu. LCD TEST Press any key to continue . . . _
Real-Time Clock Test Select the option from the for the Test" screen: RTC TEST 08–10–1999 Tue. 11:01:37.32_
The date and time given should be current. If not, exit the Mode" and access the Mode." Go into the option and select option 1 to reset the date or time. Press any key to return to the menu.
M90 Series Portable Data Entry Unit Reference Manual
3-37
Page 68
Operation Modes
SECTION 3
Scanner Test Select option from the menu for the Test" screen to test the M90 scanner on bar code labels. A successful scan will give the data, type, and scan information: SCANNER TEST Wait scanning . . . _
When doing a test, aim the M90 at a bar code, then press [ENT SCAN] to start the scan. A red laser should appear on the bar code to read, then if successful, the M90 emits a beep and lists the bar code information on the display. Press the [ENT SCAN] key to do another bar code, or press any key to exit.
RAM Backup Test Select option BACKUP" from the menu for the RAM back up test screen. Press [0] to return to the menu, or press [1] to continue with the memory flush. !! WARNING !! Will Flush RAM & RAM Disk ! Continue ? 1=YES/0=NO
3-38
M90 Series Portable Data Entry Unit Reference Manual
Page 69
SECTION 3
Operation Modes
If you pressed [1] to continue, the following instructions apĆ pear on the display: RAM Backup TEST Wait 30 seconds After power off, Then turn it on Again Press any key to Turn it off . . . _
To do the test, remove the battery pack from the M90 to turn the unit off, wait 30 seconds, reinsert the battery pack, then turn on the M90. A Wait" message appears on the display, followed by this pass/fail screen: RAM Backup TEST PASS ! Press any key to Continue . . . _
Return to Supervisor Mode Press option from the menu to reĆ turn to the Mode." The M90 will then perform a warm start. If the M90 memory was tested, the M90 will perform a cold start.
M90 Series Portable Data Entry Unit Reference Manual
3-39
Page 70
Operation Modes
3-40
M90 Series Portable Data Entry Unit Reference Manual
SECTION 3