Page 301
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Scanner Mode Purpose:
Defines how the scanner operates when you pull the trigger. Two scanner modes are available: •
One-shot mode requires you to pull the trigger each time you want to scan a bar code. Once the bar code is scanned, the scanner turns off.
•
Automatic mode allows you to pull the trigger once and scan a series of bar codes. Releasing the trigger turns the scanner off. To scan the same bar code more than once, you must release the trigger or scan a different bar code before attempting a second scan.
Note: This configuration is applicable only when using a scanner with the reader. Default:
One-shot mode
Syntax:
SBdata Acceptable values for data are: 0 1
Scan:
One-shot mode 1461 Automatic mode
One of the following labels: One-Shot Mode
*$+SB0* *$+SB0*
10-82
Automatic Mode
*$+SB1*
*$+SB1*
Page 302
39 nugget A Configuration Commands
10
Scanner Redundancy Purpose:
Defines the number of scans (voting) the scanner takes of the same label that must be decoded correctly for a good read of the label. Voting allows the JANUS 2050 to decode the same bar code label multiple times during a singletrigger event, and to compare the decoded information a specific number of times before signaling a good read. Setting the redundancy configuration to low allows the JANUS 2050 to accept the first good read, which speeds up performance. This setting is recommended for good quality bar code labels. When configured to normal, the JANUS 2050 decodes the bar code label a minimum number of times in each trigger event. When configured to high, the JANUS 2050 scans and decodes the bar code label a maximum number of times in each trigger event. The specific number of comparisons depends on each bar code symbology. For example, when you are scanning Code 39 labels and voting is configured to moderate, two successive matching decodes in a single-trigger event are required. When voting is configured to high, three successive matching decodes in a single-trigger event are required. Setting the redundancy configuration to high is important when scanning poor quality labels that may cause substitution errors.
Default:
Normal
Syntax:
SRdata Acceptable values for data are: 0 1 2
Scan:
None Normal High
One of the following labels: None
*$+SR0* *$+SR0*
Normal
*$+SR1*
*$+SR1*
High
*$+SR2* *$+SR2*
10-83
Page 303
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Scanner Timeout Purpose:
Defines the maximum length of time the scanner stays on following each trigger pull.
Default:
No timeout
Syntax:
SAdata Acceptable values for data are: 0 1-60
Scan:
Disabled Shutoff time in seconds
1. Scan the following bar code: Enter Accumulate / Scanner Timeout
*+/$+SA* *+/$+SA*
2. Scan a numeric value for data from the following bar codes:
*0*
*1*
*2*
*3*
*0*
*2*
*3*
*4*
*5*
*6*
*7*
*8*
*9*
*4*
*6*
*8*
3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-84
*1*
*5*
*7*
*9*
Page 304
39 nugget A Configuration Commands
10
Scanner Trigger Purpose:
Scanner trigger allows you to set the triggering to level or edge triggering. •
With level triggering, you pull the trigger and the laser turns on and stays on until you release the trigger.
•
In edge triggering, you pull the trigger and the laser turns on and stays on. When you pull the trigger a second time, the laser turns off. Simply releasing the trigger does not turn the laser off. If the laser is left on, the scanner timeout turns the laser off.
Default:
Level
Syntax:
SCdata Acceptable values for data are: 0 1
Scan:
Level Edge
One of the following labels: Level Trigger
*$+SC0* *$+SC0*
Edge Trigger
*$+SC1* *$+SC1*
10-85
Page 305
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
SEL (Select) Purpose:
Defines the character that requests permission for the controller to send data to the polled device. Note: You must select the communications port and protocol before setting the parameters that define the protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols.
Default:
Disabled
Syntax:
HAdata data can be any ASCII character
Scan:
To disable SEL, scan the following bar code: Disable SEL
*$+HA* *$+HA*
Or:
To set SEL to an ASCII character: 1. Scan the following bar code: Enter Accumulate / SEL
*+/$+HA* *+/$+HA*
2. Scan a bar code for data from the full ASCII chart in Appendix A. 3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-86
Page 306
39 nugget A Configuration Commands
10
SOM (Start of Message) Purpose:
SOM is the first character in a message sent to or received from the host computer. Note: You must select the communications port and protocol before setting the parameters that define the protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols.
Default:
Disabled
Syntax:
PEdata data can be any ASCII character
Scan:
To disable SOM, scan the following bar code: Disable SOM
*$+PE* *$+PE*
Or:
To set SOM to an ASCII character: 1. Scan the following bar code: Enter Accumulate / SOM
*+/$+PE* *+/$+PE*
2. Scan a bar code for data from the full ASCII chart in Appendix A. 3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-87
Page 307
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Stop Bits Purpose:
Sets the number of stop bits on the communications port. Note: You must select the communications port and protocol before setting the parameters that define the protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols.
Default:
1 stop bit
Syntax:
ICdata Acceptable values for data are: 1 2
Scan:
One stop bit Two stop bits
One of the following labels: 1 Stop Bit
*$+IC1* *$+IC1*
2 Stop Bits
*$+IC2* *$+IC2*
10-88
Page 308
39 nugget A Configuration Commands
10
Timeout Delay Purpose:
Defines the length of time the JANUS 2050 waits between characters when receiving a message. When the timeout expires, an I/O error occurs. If you are using the JANUS 2050 to use a User-Defined protocol or a Point-toPoint protocol, you should use Timeout Delay only at baud rates of 9600 or lower. You should disable Timeout Delay (IE=8) at baud rates of 19200 or higher to avoid losing incoming data. Note: You must select the communications port and protocol before setting the parameters that define the protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols.
Default:
10 sec
Syntax:
IEdata Acceptable values for data are: 0 1 2 3 4 5 6 7 8
Scan:
5 ms 100 ms 500 ms 2 sec 10 sec 20 sec 40 sec 60 sec No timeout
One of the following labels: No Timeout Delay
*$+IE8*
Timeout Delay, 5 ms
*$+IE0*
*$+IE8*
*$+IE0*
Timeout Delay, 100 ms
Timeout Delay, 500 ms
*$+IE1*
*$+IE2*
*$+IE1*
*$+IE2*
Timeout Delay, 2 sec
Timeout Delay, 10 sec
*$+IE3*
*$+IE4*
*$+IE3*
*$+IE4*
10-89
Page 309
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A Timeout Delay (continued) Timeout Delay, 20 sec
Timeout Delay, 40 sec
*$+IE5*
*$+IE6*
*$+IE5*
Timeout Delay, 60 sec
*$+IE7* *$+IE7*
10-90
*$+IE6*
Page 310
39 nugget A Configuration Commands
10
Transmit Abort Timeout Purpose:
Defines the length of time the JANUS 2050 waits to receive a message if one of the following conditions is true: •
CTS is continuously false for the timeout period.
•
XOFF condition does not change within the timeout period.
•
POL not received (polling protocol) within the timeout period.
This is similar to the Timeout Delay configuration, but it only applies to the three conditions listed above. Note: You must select the communications port and protocol before setting the parameters that define the protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols. Default:
Disabled
Syntax:
IHdata Acceptable values for data are: 0 1-65000
Disabled Timeout in ms
1. Scan the following bar code: Enter Accumulate / Transmit Abort Timeout
*+/$+IH* *+/$+IH*
2. Scan a numeric value of one to five digits for data from the following bar codes:
*0* *0*
*2* *2*
*1* *1*
*3*
*3*
10-91