The text of a manual · part 32 of 42
JANUS 2050 Vehicle-Mount Computer (4MB) User's Manual, pages 311 to 320
Pages 311 to 320 of 419
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2050
Page 311
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A Transmit Abort Timeout (continued)
*4*
*5*
*6*
*7*
*8*
*9*
*4*
*6*
*8*
3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-92
*5*
*7*
*9*
Page 312
39 nugget A Configuration Commands
10
Turnaround Delay Purpose:
Defines the length of time the JANUS 2050 waits to respond after receiving data from the host computer. Note: You must select the communications port and protocol before setting the parameters that define the protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols.
Default:
0 sec
Syntax:
IGdata Acceptable values for data are: 0 1 2 3 4 5 6 7
Scan:
0 ms 1 ms 2 ms 5 ms 10 ms 20 ms 50 ms 100 ms
One of the following labels: No Turnaround Delay
*$+IG0*
Turnaround Delay, 1 ms
*$+IG1*
*$+IG0*
*$+IG1*
Turnaround Delay, 2 ms
Turnaround Delay, 5 ms
*$+IG2*
*$+IG3*
*$+IG2*
*$+IG3*
Turnaround Delay, 10 ms
Turnaround Delay, 20 ms
*$+IG4*
*$+IG5*
*$+IG4*
*$+IG5*
Turnaround Delay, 50 ms
Turnaround Delay, 100 ms
*$+IG6* *$+IG6*
*$+IG7*
*$+IG7*
10-93
Page 313
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
UPC/EAN Purpose:
Enables/disables the decoding of Universal Product Code (UPC)/European Article Numbering (EAN) symbology. UPC/EAN are fixed length, numeric, continuous symbologies that use four element widths. An EAN-configured JANUS 2050 can decode UPC, but the reverse is not true. UPC code is a subset of EAN code. The fifth, sixth, and seventh digits are optional. Setting the sixth digit to 0 strips one leading digit from UPC-A, UPC-E, and EAN-8 and two leading digits from EAN-13. If you want to set the sixth digit, you must also set the fifth digit.
Default:
UPC-A/EAN-13, UPC-E, and EAN-8 enabled, supplementals allowed, transmit check digit, transmit number system digit, and retain UPC-A leading zero
Syntax:
CEdata data must be 4 to 7 digits selected from the following list:
Scan:
First digit:
0 1 2
UPC-A/EAN-13 disabled UPC-A/EAN-13 enabled UPC-A only
Second digit:
0 1
UPC-E disabled UPC-E enabled
Third digit:
0 1
EAN-8 disabled EAN-8 enabled
Fourth digit
0 1
Supplementals not allowed Supplementals allowed
Fifth digit:
0 1
Discard check digit Transmit check digit
Sixth digit:
0 1
Discard number system digit Transmit number system digit
Seventh digit:
0 1
Discard UPC-A leading zero Retain UPC-A leading zero
To disable UPC/EAN, scan the following bar code: Disable UPC/EAN
*$+CE000000* *$+CE000000*
10-94
Page 314
39 nugget A Configuration Commands
10
UPC/EAN (continued) Or:
To enable UPC/EAN: 1. Scan the following bar code: Enter Accumulate / UPC/EAN
*+/$+CE* *+/$+CE*
2. Scan one of the following for the first digit: Disable UPC/EAN-13
Enable UPC/EAN-13
*0*
*1*
*0*
*1*
UPC-A only
*2* *2*
3. Scan one of the following for the second digit: Disable UPC-E
Enable UPC-E
*0*
*1*
*0*
*1*
4. Scan one of the following for the third digit: Disable EAN-8
Enable EAN-8
*0*
*1*
*0*
*1*
10-95
Page 315
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A 5. Scan one of the following for the fourth digit: Supplementals Not Allowed
Supplementals Allowed
*0*
*1*
*0*
*1*
6. (Optional) Scan one of the following for the fifth digit: Discard Check Digit
Transmit Check Digit
*0*
*1*
*0*
*1*
7. (Optional) Scan one of the following for the sixth digit: Discard Number System Digit
Transmit Number System Digit
*0*
*1*
*0*
*1*
8. (Optional) Scan one of the following for the seventh digit: Discard UPC-A Leading Zero
Retain UPC-A Leading Zero
*0*
*1*
*0*
9. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-96
*1*
Page 316
11 Advanced Operations
Page 317
Page 318
39 nugget A Advanced Operations
11
This chapter explains how to make more memory available for applications, how to access and use the boot loader screen, how to set the password, and how to put the JANUS 2050 in Storage mode.
Making More RAM Available on the JANUS 2050 Your JANUS 2050 may not have enough conventional memory (RAM) available for the JANUS applications you want to run. If so, you can free up some conventional memory by not installing the PC card drivers and by unloading two TSR programs (TSRs) from your JANUS 2050’s memory. The next sections describe how and when to perform these tasks: •
Not installing the PC card drivers to free up about 60K.
•
Unloading the Reader Wedge TSR to free up about 80K.
Note: If you do not need to free up more conventional memory on your JANUS 2050, you do not have to perform these tasks.
Not Installing the PC Card Drivers You do not need to install PC card drivers if you are not using PC cards in your reader. You may be able to save up to 60K in conventional memory by not installing the drivers. Choose the No PC Card option on the MS-DOS startup menu and PC card drivers will not be installed when you boot the reader.
MS-DOS 6.2 Startup
1. SRAM PCCard 2. ATA PCCard 3. Flash PCCard 4. I/O PCCard 5. No PCCard Enter a choice:
F5=Bypass startup file
20X0A.002
Unloading the Reader Wedge TSR The Reader Wedge TSR (RWTSR.EXE) must be loaded in memory before you can call Reader Wedge PSK functions such as im_receive_input. However, when you finish your PSK application, you no longer need RWTSR.EXE in memory. You can save about 80K by unloading RWTSR.EXE with this command: rwtsr -d
You can load RWTSR.EXE with this command: rwtsr
11-3
Page 319
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Accessing the Boot Loader Menu The Boot Loader menu appears when you enter a designated key combination, the system flash is corrupt, the BIOS checksums fail, or if the JANUS 2050 cannot resume. From the Boot Loader menu you can perform a cold boot, change the password, put the JANUS 2050 in Storage mode, load system flash, or perform a memory dump. To request the Boot Loader menu Note: If you do not press a key within 60 seconds after a screen is displayed, the JANUS 2050 automatically shuts off and you have to start over at Step 1. 1. Turn off the JANUS 2050 by pressing the q button. 2. Press n - 2 - g at the same time. 3. Press 2 . 4. Press q to turn the JANUS 2050 on. 5. If the password is not set, you immediately go to the Boot Loader menu. If the password is set, the Password screen is displayed and you must type in the password. You are allowed three tries to enter the password. Note: The JANUS 2050 is shipped from the factory with the password disabled. The Boot Loader menu lists the options available and displays status messages or checksums at the bottom of the screen. Reboot This option performs a cold boot of the JANUS 2050. A cold boot clears the internal conventional memory and destroys all buffered data.
Boot Loader Reboot Password Dump Load Resume Storage Off
2050U.067
CAUTION
Caution When the JANUS 2050 performs a cold boot, data on the RAM disk is destroyed. Conseil Lorsque le lecteur s’amorce à froid, les données se trouvant sur le disque RAM sont détruites.
11-4
Page 320
39 nugget A Advanced Operations
11
Password Select this option to set, change, or disable the current password. When the password is set, you must enter a password before you can go to the Boot Loader menu. Dump This selection transmits the lower 640K of memory across the serial port. It is used when the JANUS 2050 is not functioning and you need to save the data. Before selecting this option, the host computer must be connected to the JANUS 2050 and executing a program that expects the 640K of data. For more information about dumping data, see Chapter 8, “Troubleshooting.” Load Select this option to receive a program across the serial port. The program may be a transient loader capable of programming the flash, a program to reload a corrupted keypad table, or execute diagnostics. For more information about loading programs, see Chapter 8, “Troubleshooting.” Caution If the load system flash option is selected, all system data will be lost. CAUTION
Conseil Si l’option de chargement du flash système (load system flash) est sélectionnée, toutes les données système seront perdues. Resume This selection exits the Boot Loader menu and returns the JANUS 2050 to where it was before it was turned off. If the JANUS 2050 was executing a program, the program continues. If there is a bad checksum or the flash is corrupt, the JANUS 2050 cannot resume. Storage This selection puts the JANUS 2050 in Storage mode to preserve the life of the backup battery. You should put the JANUS 2050 in Storage mode whenever the JANUS 2050 is not going to be used for a couple of months. However, all RAM data is lost. Off This selection exits the Boot Loader menu and puts the JANUS 2050 into the suspend state. When the JANUS 2050 is turned on again, it resumes normal operation.
11-5