Page 291
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Plessey Purpose:
Enables/disables decoding of Plessey symbology. Plessey code is pulse-widthmodulated. It includes a start character, data characters, an eight-bit cyclic check digit, a termination bar, and usually a reverse start character. The code is continuous and not self-checking. Plessey code has two parameters that need to be configured: start code and check digit.
Default:
Disabled
Syntax:
CIdata Acceptable values for data are: 00 Disabled 10 Plessey with reverse start code 30 Transmit check digit 31 Discard check digit
Scan:
To disable Plessey: Disable Plessey
*$+CI00* *$+CI00*
Or:
To set Plessey, complete the following steps: 1. Scan the following bar code: Plessey With Reverse Start Code
*$+CI10* *$+CI10*
2. Scan one of the following bar codes to transmit or retain the check digit: Transmit Check Digit
*$+CI30* *$+CI30*
10-72
Discard Check Digit
*$+CI31*
*$+CI31*
Page 292
39 nugget A Configuration Commands
10
POL Purpose:
Solicits or requests data from a polled device. Note: You must select the communications port and protocol before setting the parameters that define the protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols.
Default:
Disabled
Syntax:
HBdata data can be any ASCII character.
Scan:
To disable POL, scan the following bar code: Disable POL
*$+HB* *$+HB*
Or:
To set POL to an ASCII character: 1. Scan the following bar code: Enter Accumulate / POL
*+/$+HB* *+/$+HB*
2. Scan a bar code for data from the full ASCII chart in Appendix A. 3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-73
Page 293
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Postamble Purpose:
Sets the postamble that is appended to any data scanned by the JANUS 2050. Common postambles include cursor controls, such as tabs or carriage return line feeds. Note: Postambles are not added to scanned data when running IRL programs.
Default:
<CR>
Syntax:
AEdata Acceptable values for data are up to 25 ASCII characters. When no data is included, the postamble is disabled. You must enclose the data within quotation marks if the data is a reserved word, such as a configuration command.
Scan:
To disable the postamble, scan the following bar code: Disable Postamble
*$+AE* *$+AE*
Or:
To set the postamble to an ASCII character string: 1. Scan the following bar code: Enter Accumulate / Postamble / Start of Data
*+/$+AE* *+/$+AE*
2. Scan a value for data from the ASCII chart in Appendix A. The postamble can be from 1 to 25 characters. 3. Scan the following bar code: End of Data / Exit Accumulate
*-/* *-/*
10-74
Page 294
39 nugget A Configuration Commands
10
Preamble Purpose:
Sets the preamble that precedes any data scanned by the JANUS 2050. Common preambles include a data location number or an operator number. Note: Preambles are not added to scanned data when running IRL programs.
Default:
Disabled
Syntax:
ADdata Acceptable values for data are up to 25 ASCII characters. When no data is included, the preamble is disabled. You must enclose the data within quotation marks if the data is a reserved word, such as a configuration command.
Scan:
To disable the preamble, scan the following bar code: Disable Preamble
*$+AD* *$+AD*
Or:
To set the preamble to an ASCII character string: 1. Scan the following bar code: Enter Accumulate / Preamble / Start of Data
*+/$+AD* *+/$+AD*
2. Scan a value for data from the ASCII chart in Appendix A. The preamble can be from 1 to 25 characters. 3. Scan the following bar code: End of Data / Exit Accumulate
*-/* *-/*
10-75
Page 295
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Records Per Block Purpose:
Defines the maximum number of data records transmitted per block of data. Usually files are transmitted record by record. This configuration allows multiple records to be transmitted per data block. A block of data is transmitted during a single transmission, like an individual data record is normally. Note: The configured option may be overridden when used with certain communications protocols. It will not be overridden when used with User-Defined protocol. You must select the communications port and protocol before setting the parameters that define the protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols.
Default:
1 record transmitted per block
Syntax:
FCdata Acceptable values for data are: 0 01-99
Scan:
All records are transmitted in one block Records transmitted per block
To have all records transmitted in one block, scan the following bar code: All Records = 1 Block
*$+FC0* *$+FC0*
Or:
To set the records per block: 1. Scan the following bar code: Enter Accumulate / Number of Records Per Block
*+/$+FC* *+/$+FC*
10-76
Page 296
39 nugget A Configuration Commands
10
Records Per Block (continued) 2. Scan a two-digit numeric value for data from the following bar codes:
*0* *0*
*2*
*1* *1*
*3*
*2*
*3*
*4*
*5*
*6*
*7*
*8*
*9*
*4*
*6*
*8*
*5*
*7*
*9*
3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-77
Page 297
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
REQ (Request for Acknowledge) Purpose:
Enables/disables a request for a repeat handshake event. If REQ is enabled, AFF and NEG must also be enabled to have a valid configuration. Note: You must select the communications port and protocol before setting the parameters that define the protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols.
Default:
Disabled
Syntax:
PDdata data can be any ASCII character.
Scan:
To disable REQ, scan the following bar code: Disable REQ
*$+PD* *$+PD*
Or:
To set REQ to an ASCII character: 1. Scan the following bar code: Enter Accumulate / REQ
*+/$+PD* *+/$+PD*
2. Scan a bar code for data from the full ASCII chart in Appendix A. 3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-78
Page 298
39 nugget A Configuration Commands
10
RES (Reset) Purpose:
Enables/disables a reset event. Note: You must select the communications port and protocol before setting the parameters that define the protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols.
Default:
Disabled
Syntax:
PCdata data can be any ASCII character.
Scan:
To disable RES, scan the following bar code: Disable RES
*$+PC* *$+PC*
Or:
To set RES to an ASCII character: 1. Scan the following bar code: Enter Accumulate / RES
*+/$+PC* *+/$+PC*
2. Scan a bar code for data from the full ASCII chart in Appendix A. 3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-79
Page 299
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Scan Ahead Purpose:
Enables/disables scan ahead. When this parameter is enabled, you can scan a number of labels that are held in a stack until the JANUS 2050 can process the data. When this parameter is disabled, you scan a label and the JANUS 2050 processes the data before the next label can be scanned.
Default:
Enabled
Syntax:
SDdata Acceptable values for data are: 0 1
Scan:
Disable - one label at a time Enable - many labels at a time
One of the following labels: Disable
*$+SD0* *$+SD0* Enable
*$+SD1* *$+SD1*
10-80
Page 300
39 nugget A Configuration Commands
10
Scanner Devices Purpose:
Specifies the the scanner type, this allows the JANUS 2050 to optimize performance when connected to that scanner. Note: When a specific scanner is selected, other scaners may not function properly.
Default:
All compatible scanners
Syntax:
SSdata Acceptable values for data are: 0 1 2 3 4
Scan:
All compatible scanners (use for 1517 scanner) 1461 CCD (not currently supported) 1500 (not currently supported) 1515 (not currently supported) 1545
One of the following labels All Compatible Scanners
1461 CCD
*$+SS0*
*$+SS1*
*$+SS0*
*$+SS1*
1500
1515
*$+SS2*
$+SS3*
1545
Symbol Scanner
*$+SS2*
*$+SS4* *$+SS4*
*$+SS3*
*$+SS5*
*$+SS5*
1550
*$+SS6* *$+SS6*
10-81