JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A Code 39 (continued) Syntax:
CBdata Acceptable values for data must be three digits, corresponding to: First digit:
0 1 2 3 4
Disabled Enabled with no check digit Enabled with check digit HIBC (health industry bar code) With AIAG check digit
Second digit:
0 1
Discard check digit Transmit check digit
Third digit:
0 1 2
Non-full ASCII Full ASCII Mixed-full ASCII
Note: Selecting HIBC Code 39 automatically sets the configuration to non-full ASCII with the check digit transmitted. Scan:
To disable Code 39: Disable Code 39
*$+CB0* *$+CB0*
Or:
To set Code 39: 1. Scan the following bar code: Enter Accumulate / Code 39
*+/$+CB* *+/$+CB*
2. Scan one of the following for the first digit: Without a Check Digit
With a Check Digit
*1*
*2*
HIBC Code 39
With AIAG Check Digit
*1*
*3* *3*
10-22
*2*
*4*
*4*
Page 242
39 nugget A Configuration Commands
10
Code 39 (continued) 3. Scan one of the following for the second digit: Discard Check Digit
Transmit Check Digit
*0*
*1*
*0*
*1*
4. Scan one of the following for the third digit: Non-Full ASCII
Full ASCII
*0*
*1*
*0*
*1*
Mixed-Full
*2* *2*
5. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-23
Page 243
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Code 49 Purpose:
Enables/disables decoding of Code 49 symbology. Code 49 is a multirow symbology for high data density. The last character in each row is used for row checking and the last two characters of the symbol are used for overall checking. Function codes designate where to place the predefined data string in a Code 49 label. Whenever a JANUS 2050 encounters a function code, it replaces the function code with the defined string before transmitting the data to the workstation. This defined string allows a single Code 49 symbol to contain several different variable length data fields. Function code 1 (F1) is used to identify a data system. Function code 2 (F2) is used to indicate the end of a data field.
Default:
Code 49 enabled, function code 1 disabled, function Code 2 set to CR LF, and Function Code 3 disabled.
Syntax:
CJdata CKdata CLdata CMdata
Code 49 Function code 1 Function code 2 Function code 3
Acceptable values for data are: Code 49:
Scan:
Function code 1:
Any two ASCII characters.
Function code 2:
Any four ASCII characters
Function code 3:
Any two ASCII characters
One of the following labels: Disable Code 49
Enable Code 49
*$+CJ0*
*$+CJ1*
*$+CJ0*
10-24
0 Disabled 1 Enabled
*$+CJ1*
Page 244
39 nugget A Configuration Commands
10
Code 49 (continued) To disable any of the function codes, scan the appropriate label: Disable Function Code 1
*$+CK* *$+CK*
Disable Function Code 2
*$+CL*
*$+CL*
Disable Function Code 3
*$+CM* *$+CM*
Or:
To set one of the function codes to a character string: 1. Scan the appropriate bar code: Enter Accumulate / Function Code 1
*+/$+CK* *+/$+CK*
Enter Accumulate / Function Code 2
*+/$+CL* *+/$+CL*
Enter Accumulate / Function Code 3
*+/$+CM* *+/$+CM*
2. Scan any character from the full ASCII chart in Appendix A. Two characters each are allowed for function code 1 and 3. Four characters are allowed for function code 2. 3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-25
Page 245
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Code 93 Purpose:
Enables/disables decoding of Code 93 symbology. Code 93 is a variable length, continuous symbology employing four element widths. It is designed to complement Code 39.
Default:
Enabled
Syntax:
CFdata Acceptable values for data are: 0 1
Scan:
Disabled Enabled
One of the following labels: Disable Code 93
*$+CF0* *$+CF0*
Enable Code 93
*$+CF1* *$+CF1*
10-26
Page 246
39 nugget A Configuration Commands
10
Code 128 Purpose:
Enables/disables decoding of Code 128 symbology. Code 128 is a very high density alphanumeric symbology. It is a variable length, continuous code employing multiple element widths. Code 128 symbology can be configured to Standard or UCC/EAN, which affects how function code 1 characters are decoded. Function code 1 characters are decoded as follows: •
If Code 128 is configured to Standard, the reader will not decode function code 1 characters in bar code labels.
•
If Code 128 is configured to UCC/EAN, the reader will decode the bar code label as standard Code 128 unless the first two characters are a start character and a function code 1. If the first two characters are a start character and a function code 1: 1. The first two characters are not transmitted. 2. The three symbology ID characters, ]C1, are transmitted. 3. The remaining Code 128 characters are decoded as standard Code 128. 4. Any subsequent function code 1 characters are translated to the ASCII GS character as a separator for variable length fields.
Default:
Standard
Syntax:
CHdata Acceptable values for data are: 0 1 2
Scan:
Disabled Standard UCC/EAN - 128
One of the following labels: Disable Code 128
*$+CH0* *$+CH0*
Standard Code 128
*$+CH1*
*$+CH1*
UCC/EAN - 128
*$+CH2* *$+CH2*
10-27
Page 247
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Command Processing Purpose:
Command processing allows you to disable JANUS 2050 commands. For example, you can disable multiple-read labels (labels starting with a blank space), which then causes them to be processed as regular labels with the leading space treated as data. The override option is a temporary setting that allows you to enable all the JANUS 2050 commands for as long as you need them. When you want to return to the previous setting, you disable the override.
Default:
All commands enabled Note: Viewport movement commands have no effect on the JANUS 2050.
Syntax:
DCdata Acceptable values for data are: 0 1 2 3 <command> 0 <command> 1
Disable all JANUS 2050 commands Enable all JANUS 2050 commands Disable override Enable override Disable command Enable command
Note: If all JANUS 2050 commands are disabled ($+DC0), you cannot change the JANUS 2050’s configuration or exit from an IRL program. To enable the JANUS 2050 commands you need to enter the configuration application, or edit the configuration “*.ini” file. Scan:
To enable all the JANUS 2050 commands or override the current settings, scan one of the following bar codes: Enable All Commands
Disable Override
*$+DC1*
*$+DC2*
*$+DC1*
Enable Override
*$+DC3* *$+DC3*
10-28
*$+DC2*
Page 248
39 nugget A Configuration Commands
10
Command Processing (continued) Or:
To disable/enable specific commands, complete the following steps: 1. Scan the following bar code: Enter Accumulate / Command Processing
*+/$+DC* *+/$+DC*
2. Scan the label combination to build the command that is being enabled/disabled. Enter Accumulate
*+* *+*
*/*
*/*
Exit Accumulate
*-* *-*
*/*
*/*
Backspace
*-* *-*
*+*
*+*
Clear
*-* *-*
*-* *-*
Backlight
*%* *%*
*.* *.*
Change Config
*$* *$*
*+*
*+*
Laser On
*/* */*
*.* *.*
10-29
Page 249
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A Command Processing (continued) Laser Off
*/* */*
*%* *%*
Viewport Up
*%* *%*
*/*
*/*
Viewport Down
*%* *%*
*+*
*+*
Viewport Right
*.* *.*
*-*
*-*
Viewport Left
*%* *%*
*-* *-*
Viewport Page Up
*.* *.*
*%* *%*
*.* *.*
*+*
*+*
Viewport Page Down
*.*
*.*
*%*
*-*
*.*
*%*
10-30
*.*
*-*
Page 250
39 nugget A Configuration Commands
10
Command Processing (continued) Viewport Home
*.* *.*
*%* *%*
*.* *.*
*/*
*/*
Viewport End
*.*
*.*
*%*
*.*
*.*
*%*
*.*
*.*
Cursor to Viewport
*.*
*.*
*%*
*%*
*.*
*%*
*.*
*%*
Viewport to Cursor
*/* */*
*-* *-*
Enter Key Code Entry
*.* *.*
*.* *.*
Transmit File
*%* *%*
*%* *%*
Set Clock
*/* */*
*+* *+*
10-31