JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A Command Processing (continued) Run Program
*/* */*
*/* */*
Exit Program
*/*
*$*
Download Program
Multiple-Read
*$O*
* *
*/*
*<SI>*
*$*
* *
Clear File
*.* *.*
*$*
*$*
Receive File
*.*
*%*
*.*
*%*
Prepare for Reboot
Reboot
*..+%*
*..%$*
*..+%*
*..%$ *
3. Scan one of the following bar codes: Disable the Command
Enable the Command
*0*
*1*
*0*
*1*
4. Repeat Steps 2 and 3 if more than one command is being disabled/enabled. 5. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-32
Page 252
39 nugget A Configuration Commands
10
Communications Port, Select Purpose:
Assigns all subsequent communications port and protocol configurations to the selected port.
Default:
COM port 1
Syntax:
ISdata Acceptable values for data are: 1 2 3 4
Scan:
COM port 1 COM port 2 COM port 3 COM port 4
One of the following labels: COM Port 1
COM Port 2
*$+IS1*
*$+IS2*
*$+IS1*
*$+IS2*
COM Port3
COM Port 4
*$+IS3*
*$+IS4*
*$+IS3*
*$+IS4*
10-33
Page 253
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Communications Port, Choosing Scanner or COM2 Purpose:
The scanner and COM2 share the same internal hardware port, as a result, scanner port usage and host port COM2 usage are mutually exclusive. The JANUS 2050 will be undamaged, but neither port will function with the other connected. The scanner port is a Fischer connector on the back of the JANUS 2050. You should scan commands to configure COM2 before enabling COM2. Note: To set serial communications parameters (such as baud rate and parity) for COM2, you must use off-the-shelf software. For example, you can execute the Mode command from the DOS prompt, or an application using COM2 can execute standard DOS commands. You cannot set serial communications parameters for COM2 with IC.EXE. Also, you cannot scan configuration commands because you have disabled the scanner port.
Default:
Scanner
Syntax:
IXdata Acceptable values for data are: 0 for scanner 1 for COM2
Scan:
This label to change from scanner to COM2: Set Scanner Port to COM2
*$+IX1* *$+IX1*
You cannot scan a command to change from COM2 to scanner because you have changed the function of the scanner port.
10-34
Page 254
39 nugget A Configuration Commands
10
Communications Port, UART Restore Purpose:
Defines the hex value used to restore the COM UART FIFO control registers when you suspend and resume the reader. You must set the FIFO control register value for the reader’s UART device if you plan to perform either of the following tasks: •
Run a communications program on COM1 without loading an Intermec protocol handler such as PHIMEC into memory.
•
Run a communications program on COM2 that changes the COM2 UART FIFO control register to use UART 16x550 mode.
Otherwise, you can use the default value (00 hex) for this parameter. For more information, see “Specifying a Value for the FIFO Control Register” in Chapter 6. Note: If your application uses UART 16x550 mode to its fullest extent, you will need to determine the appropriate setting. Default:
00
Syntax:
For COM1: IVdata For COM2: IWdata Acceptable values for data are: 00 XX
Scan:
0 Hex Two characters representing the hex value that the UART FIFO control register is set to when the JANUS 2050 is turned on
To set the hex value default, scan the following bar code: COM1: 0 Hex
*$+IV00* *$+IV00*
COM2: 0 Hex
*$+IW00*
*$+IW00*
10-35
Page 255
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A Communications Port, UART Restore (continued) Or:
To set the hex value: 1. Scan one of the following bar code: Enter Accumulate/Change Configuration/COM1
*+/$+IV* *+/$+IV*
Enter Accumulate/Change Configuration/COM2
*+/$+IW* *+/$+IW*
2. Scan two bar codes for data from the full ASCII chart in Appendix A. 3. Scan the following bar code: End Accumulate
*-/* *-/*
Repeat Steps 1 through 3 for a second COM port if necessary.
10-36
Page 256
39 nugget A Configuration Commands
10
Communications Protocol Protocol determines how the JANUS 2050 communicates with the host through the DTE interface of the selected communications port. A different protocol can be configured for each communications port. Even if you are using the same protocol for each port, each communications port must be configured separately. One advantage of this is that you can have a different protocol configured and active for each communications port. Before configuring a protocol, you need to select the communications port to which it applies with Communications Port, Select (IS). Once the protocol is configured, you need to activate the protocol.
Configure Purpose:
This command assigns all subsequent protocol configuration changes (for example, baud rate and data bits) to the selected communications protocol. Each protocol has a list of parameters that can be configured for that protocol: Note: Some of the protocol characters for User-Defined cannot be reconfigured if UserDefined is active. If User-Defined is the active protocol, set the active protocol to None. Once you are finished configuring User-Defined protocol, then reactivate the protocol. The following characters are used with IRL and Communications Manager and are not directly supported by the Intermec protocol handler. •
EOF, EOR, and # of Records per Block
•
PAK, BAK, SOP, EOP, RUN, END, and PSS
If you want to configure the JANUS 2050 for User-Defined Multi-Drop protocol, select User-Defined protocol and then go to the configuration command “Communications Protocol, Multi-Drop, User-Defined” later in this chapter.
10-37
Page 257
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A Configure (continued)
10-38
Protocol
Parameter
User-Defined
• • • • • • • •
Baud rate, parity, data, and stop bits Flow control, LRC Intercharacter, turnaround, and timeout delay Transmit abort timeout SOM, EOM POL, SEL, RES, REQ, AFF, NEG EOF, EOR, and number of records per block IRL PAK, IRL BAK, IRL SOP, IRL EOP, IRL RUN, IRL END, and IRL PSS
User-Defined Multi-Drop
• • • • •
Baud rate, parity, data, and stop bits Flow control, LRC Intercharacter, turnaround, and timeout delay Transmit abort timeout SOM, EOM
• • •
POL, SEL, RES, REQ, AFF, NEG EOF, EOR, and number of records per block IRL PAK, IRL BAK, IRL SOP, IRL EOP, IRL RUN, IRL END, and IRL PSS
Point-to-Point
• • • •
Baud rate, parity, data, and stop bits Flow control Intercharacter, turnaround, and timeout delay Transmit abort timeout
Polling Mode D
• • •
Baud rate Flow control Transmit abort timeout
Multi-Drop
• • •
Baud rate, parity, data bits Transmit abort timeout Address, Multi-Drop
PC Standard
•
Baud rate, parity, data, and stop bits
Page 258
39 nugget A Configuration Commands
10
Configure (continued) Default:
Point-to-Point
Syntax:
PSdata Acceptable values for data are: 0 1 2 3 7
Scan:
User-Defined Point-to-Point Polling Mode D Multi-Drop PC Standard
One of the following labels: User-Defined
Point-to-Point
*$+PS0*
*$+PS1*
*$+PS0*
*$+PS1*
Polling Mode D
Multi-Drop
*$+PS2*
*$+PS3*
*$+PS2*
*$+PS3*
PC Standard
*$+PS7* *$+PS7*
10-39
Page 259
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Activate Purpose:
Enables the selected protocol to be used for the preselected communications port. Each port can only have one active protocol at a time. Note: The selected protocol does not become active until the corresponding protocol handler is loaded.
Default:
Point-to-Point
Syntax:
PAdata Acceptable values for data are: 0 1 2 3 7 9
Scan:
User-Defined Point-to-Point Polling Mode D Multi-Drop PC Standard None
One of the following labels: User-Defined Protocol
*$+PA0*
*$+PA1*
*$+PA0*
*$+PA1*
Polling Mode D Protocol
Multi-Drop Protocol
*$+PA2*
*$+PA3*
*$+PA2*
*$+PA3*
PC Standard Protocol
No Protocol
*$+PA7* *$+PA7*
10-40
Point-to-Point Protocol
*$+PA9*
*$+PA9*
Page 260
39 nugget A Configuration Commands
10
Multi-Drop, User-Defined Purpose:
An option of User-Defined protocol. You must set the POL and SEL characters to define a unique device address. Refer to Appendix A for the correct POL and SEL combinations. Note: You must select User-Defined protocol before you can enable User-Defined Multi-Drop protocol. Refer to the configuration command “Communications Protocol, Configure”earlier in this chapter for more information on defining protocols. To activate User-Defined Multi-Drop protocol, select User-Defined in the configuration command Communications Protocol, Activate.
Default:
Disabled
Syntax:
PMdata Acceptable values for data are: 0 1
Scan:
Disabled Enabled
One of the following labels: Disable User-Defined Multi-Drop
*$+PM0* *$+PM0*
Enable User-Defined Multi-Drop
*$+PM1* *$+PM1*
10-41