Page 231
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A Beep Frequency (continued) 3. Scan one of the following bar codes to designate whether the setting is for a low or high beep: Low Beep
High Beep
*L*
*H*
*L* 4.
Scan the following bar code: Exit Accumulate
*-/* *-/*
10-12
*H*
Page 232
39 nugget A Configuration Commands
10
Beep Volume Purpose:
Adjusts the volume of the beeps emitted by the JANUS 2050. The beep patterns are defined in Chapter 2, “Operating the JANUS 2050.” Set the beep volume according to operator preference and work environment.
Default:
Normal
Syntax:
BVdata Acceptable values for data are: 0 1 2 3 4 8 9
Scan:
Off Quiet Normal Loud Very loud Lower volume Raise volume
One of the following labels: Off
Quiet
*$+BV0*
*$+BV1*
*$+BV0*
*$+BV1*
Normal
Loud
*$+BV2*
*$+BV3*
*$+BV2*
*$+BV3*
Very Loud
*$+BV4* *$+BV4*
Or:
Scan one of these bar codes repeatedly to achieve the desired volume: Raise Beep Volume
Lower Beep Volume
*$+BV9*
*$+BV8*
*$+BV9*
*$+BV8*
10-13
Page 233
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Codabar Purpose:
Enables/disables decoding of Codabar symbology. Codabar is a self-checking, discrete symbology having 16 characters in its set: 0-9, dollar sign ($), colon (:), slash (/), period (.), plus (+), and minus (-). Codabar is commonly used in libraries, blood banks, and air-parcel express applications. American Blood Commission (ABC) Codabar requires that start/stop code representations be retained. As a result, configuration CD10 is an illegal configuration.
Default:
Standard Codabar, ABCD start/stop transmitted
Syntax:
CDdata Acceptable values for data must be two digits, corresponding to: First digit:
0 1 2 3
Second digit: 0 1 2
Scan:
Disabled ABC Standard Concatenated Discard start/stop ABCD start/stop transmitted DC1-DC4 start/stop transmitted
One of the following labels: Codabar Disabled, Discard Start/Stop
ABC, ABCD Start/Stop
*$+CD00*
*$+CD11*
ABC, DC1-DC4 Start/Stop
Standard, Discard Start/Stop
*$+CD12*
*$+CD20*
*$+CD00*
*$+CD12*
10-14
*$+CD11*
*$+CD20*
Page 234
39 nugget A Configuration Commands
10
Codabar(continued) Standard, ABCD Start/Stop
Standard, DC1-DC4 Start/Stop
*$+CD21*
*$+CD22*
Concatenated, Discard Start/Stop
Concatenated, ABCD Start/Stop
*$+CD21*
*$+CD30* *$+CD30*
*$+CD22*
*$+CD31*
*$+CD31*
Concatenated, DC1-DC4 Start/Stop
*$+CD32* *$+CD32*
10-15
Page 235
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Code 11 Purpose:
Enables/disables decoding of Code 11 symbology. Code 11 is a very high density discrete numeric bar code. It is most extensively used in labeling telecommunications components and equipment.
Default:
Enabled with two check digits
Syntax:
CGdata Acceptable values for data are: 0 1 2
Scan:
Disabled One check digit Two check digits
One of the following labels: Disable Code 11
*$+CG0* *$+CG0*
Code 11 With One Check Digit
*$+CG1* *$+CG1*
Code 11 With Two Check Digits
*$+CG2* *$+CG2*
10-16
Page 236
39 nugget A Configuration Commands
10
Code 16K Purpose:
Enables/disables decoding of Code 16K symbology. Code 16K is a twodimensional (stacked rows), ultra-high density bar code. It is based on Code 128 and is used widely in labeling unit-dose packaging for the healthcare industry.
Default:
Standard
Syntax:
CPdata Acceptable values for data are: 0 1 2
Disabled Standard With function code 1
When you enable Code 16K with Function Code 1, the reader decodes the bar code label and checks for a Function Code 1 in the first data character position. If a Function Code 1 is the first character, the reader substitutes this Code 16K symbology identifier string for the Function Code 1 character. Scan:
One of the following labels: Disable Code 16K
*$+CP0* *$+CP0*
Code 16K, Standard
*$+CP1* *$+CP1*
Code 16K With Function Code 1
*$+CP2* *$+CP2*
10-17
Page 237
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Code 2 of 5 Purpose:
Enables\disables decoding of Code 2 of 5 symbology. Code 2 of 5 uses the bars to encode information and the spaces to separate the individual bars. This code is discrete and self-checking. Decoding for Code 2 of 5 code can only be enabled if decoding for the Interleaved 2 of 5 code is disabled. If Interleaved 2 of 5 is enabled, Code 2 of 5 code is automatically disabled.
Default:
Disabled
Syntax:
CCdata data consists of three digits as follows:
Scan:
First digit:
0 1
3 bar start/stop 2 bar start/stop
Second and third digits:
00 Disable 2 of 5 01-32 Label length
To disable 2 of 5, scan the following bar code: Disable 2 of 5
*$+CC000* *$+CC000*
Or:
To enable 2 of 5 decoding: 1. Scan one of the following bar codes: 2 of 5, 3 Bar Start / Stop
*+/$+CC0* *+/$+CC0*
2 of 5, 2 Bar Start / Stop
*+/$+CC1* *+/$+CC1*
10-18
Page 238
39 nugget A Configuration Commands
10
Code 2 of 5 (continued) 2. Scan a two-digit numeric value for the label length (01 to 32) from the following bar codes.
*0* *0*
*2*
*1* *1*
*3*
*2*
*3*
*4*
*5*
*6*
*7*
*8*
*9*
*4*
*6*
*8*
*5*
*7*
*9*
3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-19
Page 239
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Code 39 Purpose:
Enables/disables decoding of Code 39 symbology. Code 39 is discrete, variable length, and self-checking. The character set is A-Z uppercase, 0-9, dollar sign ($), period (.), slash (/), percent (%), space ( ), plus (+), and minus (-). There are three types of ASCII decoded by the JANUS 2050: non-full ASCII, full ASCII and mixed-full ASCII. Code 39 non-full ASCII uses a one character encoding scheme. Therefore, the data “READER” is encoded as follows:
*READER* *READER*
This label decodes as READER. In Code 39 full ASCII, the character set is extended to 128 characters using a two-character encoding scheme. This extension is accomplished by using the dollar sign ($), slash (/), percent (%), and plus (+) as preceding characters followed by an uppercase letter. Lowercase letters must be encoded as a plus sign (+) followed by their uppercase equivalent. The ASCII characters and their Code 39 representations are listed in Appendix A. Thus in full ASCII Code 39, the data “reader” is encoded as follows:
*+R+E+A+D+E+R* *+R+E+A+D+E+R*
The label decodes as +R+E+A+D+E+R when the JANUS 2050 is configured for non-full ASCII Code 39. But, it decodes as reader when the JANUS 2050 is configured for full ASCII Code 39. Code 39 full ASCII is used to enter ASCII control characters or lowercase characters as data. It should also be enabled to allow the use of ASCII command characters. The Code 39 mixed-full ASCII configuration is used when printers encode the same label two different ways. For example, if you have a bar code with the data $%a, some printers encode the data as:
*/D/E+A* */D/E+A*
10-20
Page 240
39 nugget A Configuration Commands
10
Code 39 (continued) According to the full ASCII table in Appendix A, $ is represented by /D and % is represented by /E. This data is decoded as $%a if the JANUS 2050 is configured for full ASCII, because all the data is represented by valid full ASCII characters pairs. Other printers encode the data $%a as:
*$%+A* *$%+A*
The $ and % are valid Code 39 characters in the non-full ASCII character set. However, this label will NOT be decoded by the JANUS 2050 if it is configured for full ASCII, because the data is NOT represented by valid full ASCII character pairs. To decode the label correctly, configure the JANUS 2050 for mixed-full ASCII. When configured for mixed-full ASCII, the JANUS 2050 will decode both of the labels above as $%a. Mixed-full ASCII interprets any valid full ASCII character pairs that appear in the label, but does not require that all data be encoded with a valid full ASCII character pair. If you are uncertain how your labels are encoded, configure the JANUS 2050 for mixed-full ASCII, which decodes all valid Code 39 labels. If you are configuring the JANUS 2050 for Code 39 full ASCII, you should check for mixed-full ASCII. Mixed-full ASCII does not apply when you are configuring the JANUS 2050 for non-full ASCII. Note: The interpretive text found under bar code labels does not always accurately reflect the data that is encoded in the label. The interpretive text represents how the label should be decoded. The following table can aid you in configuring your JANUS 2050.
Default:
JANUS 2050
Bar Code
Decode
Non-full ASCII
$%+A /D/E+A
$%+A /D/E+A
Full ASCII
$%+A /D/E+A
No decode $%a
Mixed-full ASCII
$%+A /D/E+A
$%a $%a
Enable full ASCII with no check digit (111)
10-21