Page 221

This page is a scan with no text; see it in the PDF.

Page 222

39 nugget A Configuration Commands

10

This chapter provides an alphabetical list of all the configuration commands supported on the JANUS 2050.

Using Configuration Commands A configuration command modifies JANUS 2050 operation. You can scan configuration commands from a bar code label, execute them in an IRL program, and enter them from the JANUS 2050 keypad to a user application, or send them from a host computer to a user application. Note: Configuration commands from the keypad and host computer can only be sent to an application designed to accept the command syntax. This chapter provides the following information on each configuration parameter: •

Command description

•

Default setting

•

Command syntax and options

•

Bar codes containing the configuration parameters

The commands appear alphabetically by command name. If you want to look up a command by its syntax, refer to the “Configuration Command by Syntax” table in Appendix A. The following JANUS configuration commands have no effect on the JANUS 2050, and are not included in this manual. •

Display Backlight Timeout ($+DF)

•

Display Contrast ($+DJ)

•

Viewport Movement Keys ($+DV)

•

Viewport Movement Steps ($+DY)

•

Communication Dock Port Select ($+IP)

10-3

Page 223

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A

Variable Data You must enter commands that require variable data in the following sequence. For example, you can set the EOF character to any ASCII character. If you want to set the EOF character to SOH: 1. Scan the following bar code to enter Accumulate mode and change the configuration ($+) for EOF (FA): Enter Accumulate / Set EOF

*+/$+FA*

*+/$+FA*

2. Scan a bar code from the full ASCII chart in Appendix A. SOH has been included here as an example: SOH

*$A* *<SOH>*

3. Scan the Exit Accumulate bar code: Exit Accumulate

*-/* *-/*

When the Exit Accumulate label is scanned, the JANUS 2050 updates the configuration for EOF.

10-4

Page 224

39 nugget A Configuration Commands

10

Address, Multi-Drop Purpose:

Defines the address of the communications port when using Multi-Drop protocol. Each address has unique POL and SEL characters that are automatically set when the address is configured. Refer to Appendix A for the POL and SEL values that correspond to each address. Note: You must select the communications port and protocol before setting the parameters to define that protocol. For help, see ”Communications Protocol, Configure” later in this chapter.

Default:

A

Syntax:

HCdata data can be A through Z or 0 through 5.

Scan:

1. Scan the following bar code: Enter Accumulate / Address

*+/$+HC* *+/$+HC*

2. Scan a bar code for data from the full ASCII chart in Appendix A. 3. Scan the following bar code: Exit Accumulate

*-/* *-/*

10-5

Page 225

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A

AFF (Affirmative Acknowledge) Purpose:

Enables or disables the handshake event that is an affirmative acknowledge to a message. AFF and NEG must both be enabled to have a valid configuration. Note: You must select the communications port and protocol before setting the parameters to define that protocol. Refer to the configuration command “Communications Protocol, Configure” later in this chapter for more information on defining protocols.

Default:

AFF disabled

Syntax:

PGdata data can be any ASCII character.

Scan:

To disable AFF, scan the following bar code: Disable AFF

*$+PG* *$+PG*

Or:

To set AFF to an ASCII character: 1. Scan the following bar code: Enter Accumulate / AFF

*+/$+PG* *+/$+PG*

2. Scan a bar code for data from the full ASCII chart in Appendix A. 3. Scan the following bar code: Exit Accumulate

*-/* *-/*

10-6

Page 226

39 nugget A Configuration Commands

10

Baud Rate Purpose:

Sets the baud rate for the selected communications port on the JANUS 2050. It must match the baud rate of the device (for example, the host computer) that the JANUS 2050 is communicating with. Note: You must select the communications port and protocol before setting the parameters to define that protocol. Refer to the configuration command “Communications Protocol, Configure” later in this chapter for more information on defining protocols. For Polling Mode D protocol, the baud rate must be 1200 or higher. For MultiDrop protocol, the baud rate must be 2400 or higher.

Default:

9600 baud

Syntax:

IAdata Acceptable values for data are: 0 1 2 3 4 5 6 7 8

Scan:

110 baud 300 baud 600 baud 1200 baud 2400 baud 4800 baud 9600 baud 19200 baud 38400 baud

One of the following labels: 110 Baud

*$+IA0* *$+IA0*

300 Baud

*$+IA1* *$+IA1*

600 Baud

*$+IA2* *$+IA2*

10-7

Page 227

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A Baud Rate (continued) 1200 Baud

*$+IA3* *$+IA3*

2400 Baud

*$+IA4* *$+IA4*

4800 Baud

*$+IA5* *$+IA5*

9600 Baud

*$+IA6* *$+IA6*

19200 Baud

*$+IA7* *$+IA7*

38400 Baud

*$+IA8* *$+IA8*

10-8

Page 228

39 nugget A Configuration Commands

10

Beep Duration Purpose:

Defines the individual beep duration of the default/IRL JANUS 2050 beeps. There are two types of beeps: high/IRL1 and low/IRL0.

Default:

50 ms for both high and low beeps

Syntax:

BDdata Acceptable values for data are: from 1 ms to 60000 ms (60 seconds).

Scan:

1. Scan the following bar code: Enter Accumulate / Beep Duration

*+/$+BD* *+/$+BD*

2. Scan a numeric value for data in ms from the following bar codes:

*0*

*1*

*2*

*3*

*0*

*1*

*2*

*3*

*4*

*5*

*6*

*7*

*8*

*9*

*4*

*6*

*8*

*5

*7*

*9*

10-9

Page 229

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A Beep Duration (continued) 3. Scan one of the following bar codes to designate whether the setting is for a low or high beep: Low Beep

High Beep

*L*

*H*

*L*

4. Scan the following bar code: Exit Accumulate

*-/* *-/*

10-10

*H*

Page 230

39 nugget A Configuration Commands

10

Beep Frequency Purpose:

Defines the individual frequencies of the default/IRL JANUS 2050 beeps. There are two types of beep: high/IRL 1 and low/IRL 0.

Default:

1000 Hz for low beeps 2000 Hz for high beeps

Syntax:

BFdata Acceptable values for data are: from 20 to 20,000 Hz (20 KHz). Note: Setting the frequency outside the range of 100 Hz to 10,000 Hz makes the beeps inaudible.

Scan:

1. Scan the following bar code: Enter Accumulate / Beep Frequency

*+/$+BF* *+/$+BF*

2. Scan a numeric value for data in Hz from the following bar codes:

*0* *0*

*2*

*1* *1*

*3*

*2*

*3*

*4*

*5*

*6*

*7*

*8*

*9*

*4*

*6*

*8*

*5*

*7*

*9*

10-11