Page 211
Page 212
39 nugget A Command Reference
9
This chapter provides an alphabetical listing of commands that can be executed when operating the JANUS 2050. The information for each command includes a description of the command, the syntax for the command, and a bar code label containing the command syntax.
Using JANUS 2050 Commands A command causes the JANUS 2050 to perform a task. Commands can be scanned from a bar code label, entered from the keypad, sent from a host computer, or executed in an IRL program. JANUS 2050 commands can be grouped together (concatenated) into one string. For example, the command to switch the backlight on is %.1, and the command to raise the beep volume is $+BV9. These two commands can be concatenated as shown here and downloaded from a host computer: %.1$+BV9
By adding start/stop codes, you can create a bar code that does the same thing: Backlight On/Raise Beep Volume
*%.1$+BV9* *%.1$+BV9*
Concatenated commands are executed in the order in which they appear in the string. If the JANUS 2050 encounters an incorrect command, it performs the valid commands preceding the invalid command and ignores the remainder of the string. When there is an error, the JANUS 2050 emits three low beeps. Note: JANUS 2050 commands from the keypad and host computer work only when an application is using Reader Services. IRL-related commands work only when the IRL Desktop is running.
9-3
Page 213
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Enter/Exit Accumulate Accumulate mode is used to accumulate all scanned data in the JANUS 2050 data buffer. When accumulate mode is exited, the accumulated data is “entered” as a data record into the JANUS 2050. The buffer is cleared by one of the following commands: •
An Exit accumulate command
•
An Enter command
•
A Clear command
•
Any type of reset
Up to 250 characters can be held in the buffer. If the data record count exceeds 250 characters, the last bar code read is rejected, and the JANUS 2050 sounds an error beep.
Enter Accumulate Purpose:
Enters accumulate mode. Do not press any keys when using the enter accumulate command; they are not entered into the JANUS 2050.
From host:
Not supported
Keypad:
+/
IRL command:
Not supported
Scan:
Enter Accumulate
*+/* *+/*
9-4
Page 214
39 nugget A Command Reference
9
Exit Accumulate Purpose:
Exits accumulate mode and transmits the current data record. If no data has been accumulated, an empty data record is transmitted.
From host:
Not supported
Keypad:
-/
IRL command:
Not supported
Scan:
Exit Accumulate
*-/* *-/*
Backspace, Destructive Purpose:
Deletes the last character from the current data record. If there is no data in the buffer, the JANUS 2050 emits three low beeps.
From host:
Not supported
Keypad:
b or f .
IRL command:
Not supported
Scan:
Backspace, Destructive
*$H* *$H*
9-5
Page 215
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Change Configuration Purpose:
Must precede any configuration command parameter. If a valid string is entered, the JANUS 2050 configuration parameters are modified and the JANUS 2050 sounds a high beep. The configuration parameters and their options are listed in Chapter 10, “Configuration Commands.”
From host:
$+command
Keypad:
$+command
IRL command:
Z“$+command”
Scan:
Change Configuration
*$+* *$+*
Enter a configuration command or scan a bar code label containing a configuration command. Note: The Exit Configuration command ($+command$-) is not required, but is allowed for backward compatibility.
Clear Purpose:
Deletes the entire data record being accumulated. The Clear command can also be used on preamble and postamble buffers.
From host:
Not supported
Keypad:
Not supported
IRL command:
Not supported
Scan:
Clear
*--* *- -*
9-6
Page 216
39 nugget A Command Reference
9
Command Override Purpose:
Causes the character that follows it to be treated as data. This command allows for the use of control characters in preambles, data strings, and configuration command strings.
From host:
<DLE>
Keypad:
c P ^P is also the ASCII Data Link Exception character (DLE). ^P causes the character that follows it to be received as data, even if it is a protocol character. Therefore, to interpret a Command Override command from the host, the command must be preceded by DLE. For example, when “^P^P^M” is sent from the host, it is interpreted as “^P^M”, where ^P is acknowledged allowing the following command (^M) to be interpreted as data and passed on to the application. When “^P^M” is sent from the host, it is interpreted as ^M, the display is not affected, and the Carriage Return command is executed.
IRL command:
Z“^P”
Scan:
Command Override
*$P* *<DLE>*
The JANUS 2050 uses c - P as the Command Override command; however, the DOS printer redirection command ( c - P ) is also supported on the JANUS 2050. This dual purpose may cause some conflicts. If you have Reader Services loaded and scan the bar code label <DLE>, the first scan is interpreted as a JANUS 2050 command. The next <DLE> entered causes a c - P to be entered into the expanded key buffer. DOS takes this c - P and enables printer-redirection. If no printer is connected, all subsequent entries cause an error and the following message is displayed: Write fault error writing device PRN Abort, Retry?
9-7
Page 217
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Enter Purpose:
Causes the JANUS 2050 to enter the current data record. It completes the entry of a command. If no data exists, a null string is entered.
From host:
Not supported
Keypad:
e
IRL command:
Not supported
Scan:
Enter
** **
DOS shuts off the printer echo for the duration of the error, which allows it to display the error. As long as the printer echo has been requested (by entering a c - P ), DOS turns the printer echo back on after the critical error is corrected. You can exit the critical error by pressing c - P (to turn off console echo to the printer), and then pressing A (to abort).
Prepare for Reboot Purpose:
Causes the PSK library to notify the BFT-ready PSK application that the host wants to reboot the system and establish a binary file transfer (BFT) session. The PSK application accepts the Prepare for Reboot command and sends a Ready for Reboot message to the host. For help, see “Communicating With the JANUS 2050” in Chapter 6.
From Host:
..+%1
Prepare for Reboot
..+%0
Cancel the Prepare for Reboot command
Keypad:
Not supported
IRL command:
Not supported
Scan:
Not supported
9-8
Page 218
39 nugget A Command Reference
9
Reboot Purpose:
Causes the JANUS reader to warm boot and establish a binary file transfer (BFT) session with a host computer. The host must have already sent a Prepare for Reboot command and the BFT-ready PSK application has responded with a Ready for Reboot message. For help, see “Communicating With the JANUS 2050” in Chapter 6.
From Host:
..%$1
Reboot
..%$0
Cancel the Reboot command
Keypad:
Not supported
IRL command:
Not supported
Scan:
Not supported
9-9
Page 219
Page 220
10 Configuration Commands