Page 201

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A

Using MakeDisk (continued) Message

Explanation/Solution

Makedisk was unable to complete the drive image. Try again.

You may receive this message for several types of general faults such as: •

One or more of the files in the source directory could not be accessed. This could indicate a corrupt file or a bad disk.

•

A network error occurred when DOS attempted to retrieve a remote file.

•

DOS was unable to read the source directory for any number of reasons.

Please specify a source path where your drive image can get its files from.

Enter a valid subdirectory name where your source files reside that will be used to create the drive image. (This is the /s=[path] argument).

The root directory can only contain [n] files; your source files exceed this count. Place some of your root files in a subdirectory as an alternative.

Your source directory (first level) contains more than the maximum number of files and/or subdirectories permitted for the target drive’s root directory. One approach to solve this is to place some of the first-level files in a subdirectory below your source directory.

The system has too many files open; unable to create a drive image. Increase the 'FILES=' setting in your CONFIG.SYS file or terminate other applications that may be running.

MakeDisk needs to open several files during the image file creation process, but is unable to do so. You may need to terminate other applications or close some files in order to complete the MakeDisk process.

Your source files would create a [n] byte image file which is [n] bytes in excess of drive [C: or D:]'s capacity.

The total size of the files and subdirectories in your source directory, including the overhead space required to emulate a DOS compatible drive, exceeds the storage capacity of the JANUS drive you have targeted.

8-18

Page 202

39 nugget ATroubleshooting code nugget 39 helcond

8

Using PutDisk This table lists messages that you may see when you use PutDisk to load a new image file to drives C or D. Message

Explanation/Solution

Attempt to allocate memory failed, unable to proceed.

This indicates that there is not enough conventional DOS memory available for PutDisk to complete the flash update process. You may need to unload (terminate) some applications, device drivers, or TSR programs to free the needed memory.

Attempted to upgrade a ROM drive, unable to proceed.

PutDisk has determined that the target JANUS drive is comprised of ROM (read-only memory, which cannot be written to by PutDisk) instead of flash memory. Other kinds of system faults can lead PutDisk to make this determination in error, such as a flash programming voltage fault or address decoding problems.

Attempted upgrade in a RAM region, unable to proceed.

PutDisk has determined that the target JANUS drive is comprised of RAM (random access memory, which cannot support a non-volatile drive) instead of flash memory. Other kinds of system faults can lead PutDisk to make this determination in error, such as faulty flash memory or address decoding problems. You may need technical support to solve this type of error.

Cannot upgrade an unsupported drive.

Attempts to update a JANUS drive other than C or D are unsupported. Restart PutDisk, and specify the drive /d=[drvletter] as either C or D.

•

Fault has occurred during attempt to erase flash memory.

•

Fault has occurred during attempt to write flash memory.

If either of these messages persist after retrying PutDisk with a fresh battery or charging source, it may indicate a flash memory hardware failure on the JANUS device.

Image checksum failed comparison with checksum of received data.

This may indicate that the flash memory update was incomplete. You will need to restart PutDisk using the same image file.

Image file error: Drive image file is larger than the drive's BPB capacity.

The size of the drive image file is larger than is declared valid by the formatting portion of the image file. You will have to reconstruct the drive image file by using the MakeDisk utility.

Image file error: Drive image file is larger than the flash media capacity.

The size of the image file is larger than the targeted drive’s flash memory on the JANUS device. You must reduce the total file content (total size) of the drive image file by rebuilding it with the MakeDisk utility using fewer or smaller files.

8-19

Page 203

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A

Using PutDisk (continued) Message

Explanation/Solution

Image file error: Drive image file is too small to be valid.

You have attempted to write an image file to a JANUS drive that is smaller than the minimum permitted size for an image file. The minimum image file size is unique for each JANUS drive (for example, the image file may target a JANUS drive other than the one you attempted to write it to).

Image file error: Drive image type is not compatible with reader's DOS version.

You have attempted to write a drive image intended for a 1MB JANUS device to a 4MB JANUS device, or vice versa.

Image file error: Image is not compatible with the specified drive.

If the image file you attempted to write to drive C, was created for drive D, it must only be written to drive D.

Image file error: Received image data has exceeded the specified image file size.

This generally indicates a communications error or a DOS file I/O error. You should retry PutDisk to see if the problem persists. If the problem is related to the use of Intersvr/Interlnk or a remote drive that is networked using another method, you need to determine if a communications problem exists before proceeding.

•

Image file error: Unrecognized drive image type.

•

Image file error: Drive image contains an invalid or unsupported BPB.

These messages indicate that the image file you attempted to write to a JANUS drive is either corrupt, or is an invalid image file format for the JANUS device. Build a fresh image file using the MakeDisk utility.

Image file not found.

PutDisk was unable to find the image file you specified on the command line as the /i=[imagefile] argument.

Power management fault has occurred on reader.

PutDisk attempts to cooperate with JANUS power management processes; however, rare circumstances may cause a temporary fault. The best remedy for this problem is to reboot the JANUS device after PutDisk completes. If a flash update was not completed due to this fault, restart PutDisk after rebooting.

Reader's programming voltage failed during flash operation.

This message will likely occur if the battery level is borderline. You will need to restart PutDisk after installing a fresh battery or connecting the JANUS device to a charging source. If the drive being updated was drive C, it is unlikely that you will be able to reboot to the MS-DOS prompt, however you may be able to continue by rerunning PutDisk from the current MS-DOS session (without rebooting). If this method fails, you will need to enter the boot screen and use LOADER.EXE to update the JANUS drive C.

8-20

Page 204

39 nugget ATroubleshooting code nugget 39 helcond

8

Using PutDisk (continued) Message

Explanation/Solution

Reader's programming voltage has failed operational limits.

The flash programming voltage source has exceeded the acceptable current limit. This may be due to other PC Cards that use flash programming voltage. Retry PutDisk after removing all PC Cards other than SRAM cards.

Specified image file path is not valid.

This error can be caused by either an invalid path name (for example, a path that doesn't exist or a "not ready" drive), or a path\filename that contains characters that DOS does not recognize as valid characters in filenames.

The reader’s battery is too low to proceed with flash operations.

You must install a fresh battery or connect the JANUS device to either a charger via the optical link adapter or a communications dock before proceeding with the flash update.

Unable to activate Reader's A20 signal.

This may indicate either a conflict with other software that controls the A20 signal, or a hardware problem on the JANUS device. Try using PutDisk again, after terminating any suspect applications or utility programs. Another alternative is to enter the boot screen and attempt the use of LOADER.EXE to update the drives C or D.

Unable to activate reader's programming voltage, cannot proceed.

This message indicates that flash memory cannot be updated due to flash programming voltage problems. If the problem persists after installing a fresh battery or connecting the JANUS device to a charging source, there may be a hardware problem that requires service.

Unable to assert PM control due to concurrent PM host running on reader.

In this context, PM refers to protected mode which is used to access the extended memory regions assigned to the flash memory for JANUS drives. If another application is running that uses PM, it will likely introduce a conflict with PutDisk. You need to terminate (or uninstall) the application that is causing the conflict. Programs in this category include DOS extenders and EMM386 (which is not supported on the JANUS device).

Unable to engage reader's programming voltage, cannot proceed.

This may indicate a conflict with another process or device that uses flash programming voltage. Remove any PC Cards (other than SRAM cards) from the JANUS device.

Unable to resume flash drive upgrade; must be restarted.

PutDisk was unable to continue the flash update process that was interrupted with a power-down suspend/resume cycle. You need to restart PutDisk. First attempt to rerun PutDisk in the current MS-DOS session. If this fails, you will need to reboot to the MS-DOS prompt before restarting PutDisk. If the target drive was C and the JANUS device will no longer boot to the MS-DOS prompt, you will need to enter the boot screen and use LOADER.EXE to update drive C.

8-21

Page 205

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A

Using PutDisk (continued) Message

Explanation/Solution

Upgrade failed, but original drive contents have been preserved.

This message may be displayed in conjunction with another specific fault message showing the cause of PutDisk interruption. It means that although the drive update was attempted, the original files on the target drive have not been altered and are therefore safe to use.

Scanning Bar Code Labels If you have trouble operating the laser scanner, perform the following checks: •

Make sure the JANUS 2050 is turned on. Press the q button on the keypad to turn the JANUS 2050 on.

•

Inspect the print quality of the bar code label. Try scanning a known-good bar code label for comparison.

•

Try scanning the bar code label again, but vary the scanning angle and distance.

•

Clean the scanning window with a solution of ammonia and water. Wipe dry. Do not allow abrasive material to touch the window.

•

Verify that the JANUS 2050 is configured to read the bar code symbology you are scanning. Use the configuration application (IC.EXE) program to verify the bar code symbology you have configured on the JANUS 2050.

•

Verify the correct scanner type is enabled using the configuration application.

•

Verify that IF EXIST D:\RDG.BAT CALL D:\RDG.BAT is loaded from the AUTOEXEC.BAT file.

•

Try using another scanner.

Note: To prevent data loss, do not scan both multiread labels and regular labels when you are at the DOS prompt.

8-22

Page 206

39 nugget ATroubleshooting code nugget 39 helcond

8

Resetting the JANUS 2050 This section describes how to reset the JANUS 2050 by returning to the default configuration, performing a cold boot to initialize the JANUS 2050, and forcing the JANUS 2050 to shut down if the JANUS 2050 is not responding to the q button. Note: Turning off the JANUS 2050 does not clear memory. When you turn on the JANUS 2050, it returns to the same place the JANUS 2050 was before it was turned off.

Returning to the Default Configuration 1. Start the configuration application. Type the following command at the DOS prompt: ic

2. From the File drop-down menu, choose Load Default. 3. From the File drop-down menu, choose Exit. 4. When the JANUS 2050 asks if you want to update the online configuration, select Yes. The JANUS 2050 exits the configuration application and returns to the default configuration.

Performing a Cold Boot Before you perform a cold boot, attempt a warm boot. If a warm boot does not clear the problem, then perform a cold boot.

CAUTION

Caution When the JANUS 2050 performs a cold boot, all data on the RAM disk is destroyed. Conseil Lorsque le lecteur s’amorçe à froid, les données se trouvant sur le disque RAM sont détruites.

8-23

Page 207

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A

To perform a cold boot 1. Turn off the JANUS 2050 by pressing the q button. 2. Press n - 2 - b at the same time. 3. Press 2 . This is a bootstrap request. 4. Turn the JANUS 2050 on by pressing the q button. 5. If the password is set, the JANUS 2050 displays the Password screen. Type in the password, press e , and the Boot Loader menu is displayed. 6. Choose Reboot and press e . Reboot clears the internal RAM and all of its contents. If you do not want to reset the JANUS 2050, you can also select Resume and press e . The JANUS 2050 will continue executing the program.

Forcing the JANUS 2050 to Turn Off If the JANUS 2050 does not turn off when you press q , you can force it to turn off by pressing q - 5 -j at the same time. When you turn on the JANUS 2050 again, the Boot Loader menu is displayed. From the menu, you can try dumping memory or you can do a cold boot. A cold boot clears the internal RAM and all of its contents.

Saving Data and Loading Flash Memory If the JANUS 2050 cannot resume operation, you can save the JANUS 2050’s data and then use a program on the Boot Utilities companion disk to reload the system, application, and user flash memory. You can also use this same program on an upgrade disk to upgrade the JANUS 2050’s software.

Saving JANUS 2050 Data When the JANUS 2050 cannot resume, the power management software displays an error message. You can turn the JANUS 2050 off without losing data provided there is sufficient battery power. The next time the JANUS 2050 is turned on, it repeats the error sequence and returns to the Boot Loader menu. If you reboot the JANUS 2050, the data is lost. You can save the data from the JANUS 2050’s 640K memory by dumping the data to the host computer. The host computer must be running a communication program that is capable of receiving and storing the data from the JANUS 2050’s memory.

8-24

Page 208

39 nugget ATroubleshooting code nugget 39 helcond

8

To save data from the JANUS 2050 to the host computer 1. Connect the JANUS 2050 to a host computer using the communications port. The JANUS 2050 transmits and receives data at 4800 baud, no parity, 8 data bits, and 1 stop bit. 2. Run a communications program, such as Crosstalk, that saves data on the host computer. This program is not provided with the JANUS 2050. 3. If the Boot Loader menu is not already displayed, request the menu by turning the JANUS 2050 off. Press n - 2 - g at the same time. Release the keys and then press 2 . Turn the JANUS 2050 on by pressing the q button. 4. Choose Dump on the Boot Loader menu, and then press e . The JANUS 2050 downloads data from low memory (640K and below) through COM1 to the host computer. The data is transmitted in Intel hexadecimal file format. 5. A record counter on the JANUS 2050 display counts the data as it is transmitted to the host computer. The record counter stops updating when the JANUS 2050 is finished downloading the data. When the download is completed, you can reboot the JANUS 2050 or reload the JANUS 2050’s flash memory. If the system flash memory is corrupt, reload the JANUS 2050 flash memory as described in the next section.

Loading Flash Memory If the JANUS 2050 Boot Loader menu displays a checksum error message or if you need to upgrade the JANUS 2050 software, you can download all of the JANUS 2050 flash memory from a host computer. Before replacing the memory, upload any data you want saved from the JANUS 2050 to the host computer. Caution If the Load System flash option is selected, all system data will be lost. CAUTION

Conseil Si l’option de chargement du flash système (Load System Flash) est sélectionnée, toutes les données système seront perdues.

8-25

Page 209

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A

The files you need to update the JANUS 2050 flash memory are located in the self-extracting compressed file IMGx_x.EXE on the JANUS 2050 Boot Utilities companion disk. The IMGx_x.EXE file contains four files: LOADER.EXE This is the program that updates the flash memory. LOADER.EXE supports a baud rate of 38400 bps or 57600 bps. Loader updates the JANUS 2050 flash memory. To run the program at 38400 bps, you must type the Loader command on the host computer and include the /b38400 option on the command line. Here is the command syntax: loader {filenames} /comn /b38400

If you omit the /b38400 option, Loader operates at the default baud rate, 57600 bps. For details about the Loader command syntax, type this command on your host computer and press e : loader /? Note: To upgrade drive C at 38400 bps, you must enter the Loader commands manually. SYSTEM_x.x This is the 256K system flash that includes PC BIOS and part of MS ROM DOS. OTP2MEGx.x This file is for the 2MB flash that includes 80K of MS ROM DOS and the 1.9MB drive D. Drive D contains programs like Intermec’s protocol handler, IRL, Configuration Manager, and Reader Services. USER_x.x This is the 512K default drive C. It contains the factory default AUTOEXEC.BAT and CONFIG.SYS files. Note: x.x represents the software version number.

8-26

Page 210

9 Command Reference