Page 451
NF
Syntax:
BC Configuration Command Reference
12
DZdata Acceptable values for data are: 0 1
Scan:
Enable Manual Viewport Movement mode Enable Automatic Viewport Movement mode
One of these bar codes: Enable Manual Viewport Movement Mode
*$+DZ0* *$+DZ0*
Enable Automatic Viewport Movement Mode
*$+DZ1* *$+DZ1*
Viewport Movement Steps Purpose:
Defines the number of horizontal and vertical steps the viewport moves when you enter a viewport up, down, right, or left command. The horizontal steps are the number of characters the viewport moves left or right. The vertical steps are the number of lines or rows the viewport moves up or down. You must set the Display Setup command to 25 x 80 before you can move the viewport. For help, see “Display Setup” earlier in this chapter.
Default:
10 horizontal steps and 9 vertical steps
Syntax:
DYdata Acceptable values for data are: 1-20H 1-9V
Scan:
1 to 20 horizontal steps or characters 1 to 9 vertical steps or lines
To define the number of steps: 1. Scan this bar code: Enter Accumulate Mode / Viewport Movement Steps
*+/$+DY* *+/$+DY*
12-101
Page 452
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Viewport Movement Steps (continued) 2. Scan a one- or two-digit numeric value for data from these bar codes:
*0*
*1*
*2*
*3*
*0*
*1*
*2*
*3*
*4*
*5*
*4*
*6*
*5*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3. Scan one of these bar codes to set the horizontal or vertical step: Horizontal Step
*H* *H*
4. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-102
Vertical Step
*V*
*V*
Page 453
NF
BC
A Reader Specifications
Page 454
NF
BC
Page 455
NF
BC Reader Specifications
A
This appendix lists the reader’s physical and environmental specifications, and describes the types of memory available on the reader. It also lists the reader’s default configuration and provides a configuration command reference list in alphabetical order by command syntax.
Physical and Environmental Specifications You can use the tables in this section to find technical information about these features and options: • • • • • • • • • • •
Reader Dimensions Power Specifications Temperature Specifications Humidity Specifications Display Memory Data Communications Cables for Data Communications Keypad Options Symbologies Laser Scanners and Optical Parameters
Reader Dimensions Length
8.0 inches (20.3 cm)
Width
3.3 inches (8.4 cm)
Depth
2.25 inches (5.7 cm) excluding the reader handle
Weight: J2020
22 ounces (623.7 g) without the NiCad battery pack
JR2020
26 ounces (737.1 g) without the NiCad battery pack
Power Specifications Primary
Sealed 1000 mAh NiCad battery pack
Backup
1000 mAh lithium cell
A-3
Page 456
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Temperature Specifications You need to operate and store the reader within the temperature ranges listed in this table. Type of Operation
Fahrenheit Temperature Range
Celsius Temperature Range
Charging the battery pack
+50°F to +104°F
+10°C to +40°C
Operating the reader
-4°F to +122°F
-20°C to +50°C
-4°F to +95°F -4°F to +140°F
-20°C to +35°C -20°C to +60°C
Storing the reader: With the battery pack installed Without the battery pack installed
Humidity Specifications You need to operate and store the reader within the noncondensing humidity percentages listed next. Type of Humidity
Humidity Range
Operating humidity
10% to 90% relative humidity
Storage humidity
10% to 90% relative humidity
Display •
CGA compatible
•
16 lines x 20 columns, backlit LCD display
•
25 lines by 80 columns, virtual display with viewport feature
Memory
A-4
•
512K ROM drive resident in flash memory (drive C)
•
2MB ROM (drive D)
•
1MB battery-backed RAM
•
PC card drive supports Type I and II PC cards for additional storage and I/O expansion
Page 457
NF
BC Reader Specifications
A
Data Communications •
Infrared serial communications port interface
•
RS-232C, RS-422, RS-485
•
Protocols: Multi-Drop, PC Standard, Polling Mode D, User-Defined
Cables for Data Communications Use these cables with the JL2010 Optical Link Adapter to connect the reader to a host computer or other device. Cable
PC Connector
Part Number
3-wire, null modem
DB25 port connector
047569
5-wire, null modem
DB9 port connector
059167
7-wire, null modem
DB25 port connector
048693
Use these cables with the JD2020 Communications Dock to connect the reader to a host computer or other device. Note: When you run Interlnk with the reader connected to a host computer through the communications dock, you must use a 3-wire cable. Cable
PC Connector
Part Number
3-wire, null modem
DB25 port connector
052477
3-wire, null modem
DB9 port connector
047569
7-wire, null modem
DB25 port connector
048668
7-wire, null modem
DB9 port connector
048693
Keypad Options •
Full alphanumeric keypad with 54 keys available in English, French, German, Italian, and Spanish
•
Large numeric keypad with 36 keys available in English
•
Terminal emulation keypads for IBM 3270 and 5250
A-5
Page 458
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Symbologies • Codabar
• Code 93
• Code 11
• Code 128
• Code 16K
• Interleaved 2 of 5
• Code 2 of 5
• MSI
• Code 39
• Plessey
• Code 49
• UPC/EAN
Laser Scanners and Optical Parameters Visible laser diode (670 nm)
A-6
Bar Code Specification
Depth of Field Standard Laser Scanner
Depth of Field Long-Range Laser Scanner
7.5 mil code
3 to 7 inches
15.0 mil code
1 to 15 inches
5 to 30 inches
20.0 mil code
1 to 17 inches
5 to 40 inches
40.0 mil code
3 to 20 inches
6 to 50 inches
55.0 mil code
5 to 24 inches
12 to 60 inches
Page 459
NF
BC Reader Specifications
A
Default Configuration The next table shows the reader’s default configuration. You can use the Interactive Configuration application (IC.EXE) program to set the reader to the default configuration. For help, see “Restoring the Reader’s Default Configuration” in Chapter 5.
Bar Code Symbologies Parameter
Default
Codabar
Standard, ABCD start/stop transmitted
Code 11
Enabled with two check digits
Code 16K
Standard
Code 2 of 5
Disabled
Code 39
Full ASCII Code 39 enabled with no check digit
Code 49
Enabled, Function Codes 1 and 3 disabled, Function Code 2 set to CR LF
Code 93
Enabled
Code 128
Standard
Interleaved 2 of 5
Variable length with a check digit
MSI
Disabled
Plessey
Disabled
UPC/EAN
UPC-A/EAN-13 enabled, UPC-E and EAN-8 enabled, supplementals allowed, transmit check digit, transmit number system digit, and retain leading zero for UPC-A
Communications Parameter
Default
Address, Multi-Drop
A
AFF (Affirmative Acknowledge)
Disabled
Baud Rate
9600
Communications Dock Port
Network
Communications Port, Select COM Port
COM1
Communications Port, UART Restore
00 Hex
A-7
Page 460
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Communications (continued)
A-8
Parameter
Default
Communications Protocol Configure Activate User-Defined Multi-Drop
Point-to-Point Point-to-Point Disabled
Data Bits
7
EOF (End of File)
Disabled
EOM (End of Message)
Transmit and receive characters set to CR and LF
EOR (End of Record)
Disabled
Flow Control
None
Intercharacter Delay
0 seconds
IRL BAK (Bad Program Acknowledge)
BEL
IRL End Program Block
SO (shift out)
IRL EOP (End of Program)
SYN (synchronous idle)
IRL PAK (Program Acknowledge)
RS (record separator)
IRL PSS (Program Statement Separator)
CR (carriage return)
IRL Run
DC2 (device control 2)
IRL SOP (Start of Program)
SI (shift in)
LRC (Longitudinal Redundancy Check)
Disabled
NEG (Negative Acknowledge)
Disabled
Parity
Even
POL (Polling)
Disabled
Records Per Block
1 record transmitted per block
REQ (Request for Acknowledge)
Disabled
RES (Reset)
Disabled
SEL (Select)
Disabled
SOM (Start of Message)
Disabled
Stop Bits
1
Timeout Delay
10 seconds
Transmit Abort Timeout
Disabled
Turnaround Delay
0 seconds