Page 451

NF

Syntax:

BC Configuration Command Reference

12

DZdata Acceptable values for data are: 0 1

Scan:

Enable Manual Viewport Movement mode Enable Automatic Viewport Movement mode

One of these bar codes: Enable Manual Viewport Movement Mode

*$+DZ0* *$+DZ0*

Enable Automatic Viewport Movement Mode

*$+DZ1* *$+DZ1*

Viewport Movement Steps Purpose:

Defines the number of horizontal and vertical steps the viewport moves when you enter a viewport up, down, right, or left command. The horizontal steps are the number of characters the viewport moves left or right. The vertical steps are the number of lines or rows the viewport moves up or down. You must set the Display Setup command to 25 x 80 before you can move the viewport. For help, see “Display Setup” earlier in this chapter.

Default:

10 horizontal steps and 9 vertical steps

Syntax:

DYdata Acceptable values for data are: 1-20H 1-9V

Scan:

1 to 20 horizontal steps or characters 1 to 9 vertical steps or lines

To define the number of steps: 1. Scan this bar code: Enter Accumulate Mode / Viewport Movement Steps

*+/$+DY* *+/$+DY*

12-101

Page 452

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Viewport Movement Steps (continued) 2. Scan a one- or two-digit numeric value for data from these bar codes:

*0*

*1*

*2*

*3*

*0*

*1*

*2*

*3*

*4*

*5*

*4*

*6*

*5*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

3. Scan one of these bar codes to set the horizontal or vertical step: Horizontal Step

*H* *H*

4. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-102

Vertical Step

*V*

*V*

Page 453

NF

BC

A Reader Specifications

Page 454

NF

BC

Page 455

NF

BC Reader Specifications

A

This appendix lists the reader’s physical and environmental specifications, and describes the types of memory available on the reader. It also lists the reader’s default configuration and provides a configuration command reference list in alphabetical order by command syntax.

Physical and Environmental Specifications You can use the tables in this section to find technical information about these features and options: • • • • • • • • • • •

Reader Dimensions Power Specifications Temperature Specifications Humidity Specifications Display Memory Data Communications Cables for Data Communications Keypad Options Symbologies Laser Scanners and Optical Parameters

Reader Dimensions Length

8.0 inches (20.3 cm)

Width

3.3 inches (8.4 cm)

Depth

2.25 inches (5.7 cm) excluding the reader handle

Weight: J2020

22 ounces (623.7 g) without the NiCad battery pack

JR2020

26 ounces (737.1 g) without the NiCad battery pack

Power Specifications Primary

Sealed 1000 mAh NiCad battery pack

Backup

1000 mAh lithium cell

A-3

Page 456

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Temperature Specifications You need to operate and store the reader within the temperature ranges listed in this table. Type of Operation

Fahrenheit Temperature Range

Celsius Temperature Range

Charging the battery pack

+50°F to +104°F

+10°C to +40°C

Operating the reader

-4°F to +122°F

-20°C to +50°C

-4°F to +95°F -4°F to +140°F

-20°C to +35°C -20°C to +60°C

Storing the reader: With the battery pack installed Without the battery pack installed

Humidity Specifications You need to operate and store the reader within the noncondensing humidity percentages listed next. Type of Humidity

Humidity Range

Operating humidity

10% to 90% relative humidity

Storage humidity

10% to 90% relative humidity

Display •

CGA compatible

•

16 lines x 20 columns, backlit LCD display

•

25 lines by 80 columns, virtual display with viewport feature

Memory

A-4

•

512K ROM drive resident in flash memory (drive C)

•

2MB ROM (drive D)

•

1MB battery-backed RAM

•

PC card drive supports Type I and II PC cards for additional storage and I/O expansion

Page 457

NF

BC Reader Specifications

A

Data Communications •

Infrared serial communications port interface

•

RS-232C, RS-422, RS-485

•

Protocols: Multi-Drop, PC Standard, Polling Mode D, User-Defined

Cables for Data Communications Use these cables with the JL2010 Optical Link Adapter to connect the reader to a host computer or other device. Cable

PC Connector

Part Number

3-wire, null modem

DB25 port connector

047569

5-wire, null modem

DB9 port connector

059167

7-wire, null modem

DB25 port connector

048693

Use these cables with the JD2020 Communications Dock to connect the reader to a host computer or other device. Note: When you run Interlnk with the reader connected to a host computer through the communications dock, you must use a 3-wire cable. Cable

PC Connector

Part Number

3-wire, null modem

DB25 port connector

052477

3-wire, null modem

DB9 port connector

047569

7-wire, null modem

DB25 port connector

048668

7-wire, null modem

DB9 port connector

048693

Keypad Options •

Full alphanumeric keypad with 54 keys available in English, French, German, Italian, and Spanish

•

Large numeric keypad with 36 keys available in English

•

Terminal emulation keypads for IBM 3270 and 5250

A-5

Page 458

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Symbologies • Codabar

• Code 93

• Code 11

• Code 128

• Code 16K

• Interleaved 2 of 5

• Code 2 of 5

• MSI

• Code 39

• Plessey

• Code 49

• UPC/EAN

Laser Scanners and Optical Parameters Visible laser diode (670 nm)

A-6

Bar Code Specification

Depth of Field Standard Laser Scanner

Depth of Field Long-Range Laser Scanner

7.5 mil code

3 to 7 inches

15.0 mil code

1 to 15 inches

5 to 30 inches

20.0 mil code

1 to 17 inches

5 to 40 inches

40.0 mil code

3 to 20 inches

6 to 50 inches

55.0 mil code

5 to 24 inches

12 to 60 inches

Page 459

NF

BC Reader Specifications

A

Default Configuration The next table shows the reader’s default configuration. You can use the Interactive Configuration application (IC.EXE) program to set the reader to the default configuration. For help, see “Restoring the Reader’s Default Configuration” in Chapter 5.

Bar Code Symbologies Parameter

Default

Codabar

Standard, ABCD start/stop transmitted

Code 11

Enabled with two check digits

Code 16K

Standard

Code 2 of 5

Disabled

Code 39

Full ASCII Code 39 enabled with no check digit

Code 49

Enabled, Function Codes 1 and 3 disabled, Function Code 2 set to CR LF

Code 93

Enabled

Code 128

Standard

Interleaved 2 of 5

Variable length with a check digit

MSI

Disabled

Plessey

Disabled

UPC/EAN

UPC-A/EAN-13 enabled, UPC-E and EAN-8 enabled, supplementals allowed, transmit check digit, transmit number system digit, and retain leading zero for UPC-A

Communications Parameter

Default

Address, Multi-Drop

A

AFF (Affirmative Acknowledge)

Disabled

Baud Rate

9600

Communications Dock Port

Network

Communications Port, Select COM Port

COM1

Communications Port, UART Restore

00 Hex

A-7

Page 460

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Communications (continued)

A-8

Parameter

Default

Communications Protocol Configure Activate User-Defined Multi-Drop

Point-to-Point Point-to-Point Disabled

Data Bits

7

EOF (End of File)

Disabled

EOM (End of Message)

Transmit and receive characters set to CR and LF

EOR (End of Record)

Disabled

Flow Control

None

Intercharacter Delay

0 seconds

IRL BAK (Bad Program Acknowledge)

BEL

IRL End Program Block

SO (shift out)

IRL EOP (End of Program)

SYN (synchronous idle)

IRL PAK (Program Acknowledge)

RS (record separator)

IRL PSS (Program Statement Separator)

CR (carriage return)

IRL Run

DC2 (device control 2)

IRL SOP (Start of Program)

SI (shift in)

LRC (Longitudinal Redundancy Check)

Disabled

NEG (Negative Acknowledge)

Disabled

Parity

Even

POL (Polling)

Disabled

Records Per Block

1 record transmitted per block

REQ (Request for Acknowledge)

Disabled

RES (Reset)

Disabled

SEL (Select)

Disabled

SOM (Start of Message)

Disabled

Stop Bits

1

Timeout Delay

10 seconds

Transmit Abort Timeout

Disabled

Turnaround Delay

0 seconds