Page 441
NF
BC Configuration Command Reference
12
Stop Bits Purpose:
Sets the number of stop bits on the communications port. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.
Default:
1 stop bit
Syntax:
ICdata Acceptable values for data are: 1 2
Scan:
1 stop bit 2 stop bits
One of these bar codes: 1 Stop Bit
*$+IC1* *$+IC1*
2 Stop Bits
*$+IC2* *$+IC2*
12-91
Page 442
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Timeout Delay Purpose:
Defines the length of time the reader waits between characters when receiving a message. When the timeout expires, an I/O error occurs. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter. If you are using User-Defined or Point-to-Point protocol, you should only set the Timeout Delay command if the baud rate is 9600 or lower. You should disable Timeout Delay if the baud rate for either of these protocols is set to 19200 or higher.
Default:
10 sec
Syntax:
IEdata Acceptable values for data are: 0 1 2 3 4 5 6 7 8
Scan:
5 ms 100 ms 500 ms 2 sec 10 sec 20 sec 40 sec 60 sec No timeout
One of these bar codes: No Timeout Delay
Timeout Delay, 5 ms
*$+IE8*
*$+IE0*
Timeout Delay, 100 ms
Timeout Delay, 500 ms
*$+IE1*
*$+IE2*
*$+IE8*
*$+IE1*
12-92
*$+IE0*
*$+IE2*
Page 443
NF
Timeout Delay, 2 sec
*$+IE3*
BC Configuration Command Reference Timeout Delay, 10 sec
*$+IE4*
*$+IE3*
*$+IE4*
Timeout Delay, 20 sec
Timeout Delay, 40 sec
*$+IE5*
*$+IE6*
*$+IE5*
12
*$+IE6*
Timeout Delay, 60 sec
*$+IE7* *$+IE7*
12-93
Page 444
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Transmit Abort Timeout Purpose:
Defines the length of time the reader waits to receive a message if one of these conditions is true: •
CTS is continuously false for the timeout period.
•
XOFF condition does not change within the timeout period.
•
POL not received (polling protocol) within the timeout period.
Transmit Abort Timeout is similar to the Timeout Delay configuration, but it only applies to the three conditions listed above. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter. Default:
Disabled
Syntax:
IHdata Acceptable values for data are: 0 1-65000
Scan:
Disabled Timeout in ms
To disable Transmit Abort Timeout, scan this bar code: Disable Transmit Abort Timeout
*$+IH0* *$+IH0*
Or:
To set a timeout value: 1. Scan this bar code: Enter Accumulate Mode / Change Transmit Abort Timeout
*+/$+IH* *+/$+IH*
2. Scan a numeric value of one to five digits for data from these bar codes:
*0* *0*
*2* *2*
12-94
*1* *1*
*3*
*3*
Page 445
NF
BC Configuration Command Reference
*4*
*5*
*6*
*7*
*4*
*6*
*8* *8*
12
*5*
*7*
*9*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-95
Page 446
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Turnaround Delay Purpose:
Defines the length of time the reader waits to respond after receiving data from the host computer. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.
Default:
0 sec
Syntax:
IGdata Acceptable values for data are: 0 1 2 3 4 5 6 7
Scan:
0 ms 1 ms 2 ms 5 ms 10 ms 20 ms 50 ms 100 ms
One of these bar codes: No Turnaround Delay
Turnaround Delay, 1 ms
*$+IG0*
*$+IG1*
Turnaround Delay, 2 ms
Turnaround Delay, 5 ms
*$+IG0*
*$+IG2*
*$+IG3*
*$+IG2*
*$+IG3*
Turnaround Delay, 10 ms
Turnaround Delay, 20 ms
*$+IG4*
$+IG5*
*$+IG4*
*$+IG5*
Turnaround Delay, 50 ms
Turnaround Delay, 100 ms
*$+IG6*
*$+IG7*
*$+IG6*
12-96
*$+IG1*
*$+IG7*
Page 447
NF
BC Configuration Command Reference
12
UPC/EAN Purpose:
Enables or disables the decoding of Universal Product Code (UPC)/European Article Numbering (EAN) symbology. UPC/EAN are fixed length, numeric, continuous symbologies that use four element widths. A reader that is configured to decode EAN bar codes can decode UPC, but the reverse is not true. UPC code is a subset of EAN code. To define the UPC/EAN symbology, you set up to seven digits. The fifth, sixth, and seventh digits are optional. To set the sixth digit, you must set the fifth digit. To set the seventh digit, you must set all seven digits.
Default:
First digit: Second digit: Third digit: Fourth digit: Fifth digit: Sixth digit: Seventh digit:
Syntax:
CEdata
UPC-A/EAN-13 enabled UPC-E enabled EAN-8 enabled Supplementals allowed Transmit check digit Transmit number system digit Retain leading zero for UPC-A where data must be 4 to 7 digits selected from this list: First digit:
0 1 2
UPC-A/EAN-13 disabled UPC-A/EAN-13 enabled UPC-A only enabled
Second digit:
0 1
UPC-E disabled UPC-E enabled
Third digit:
0 1
EAN-8 disabled EAN-8 enabled
Fourth digit:
0 1
Supplementals are not allowed Supplementals are allowed
Fifth digit:
0 1
Discard check digit Transmit check digit
Sixth digit:
0 1
Discard number system digit Transmit number system digit
Seventh digit:
0 1
Discard the leading zero for UPC-A Retain the leading zero for UPC-A
12-97
Page 448
JANUS 2020 Hand-Held Computer User’s Manual NF BC
UPC/EAN (continued) Scan:
To disable UPC/EAN, scan this bar code: Disable UPC/EAN
*$+CE000000* *$+CE000000*
Or:
To enable UPC/EAN: 1. Scan this bar code: Enter Accumulate Mode / Enable UPC/EAN
*+/$+CE* *+/$+CE*
2. Scan one of these bar codes to set the first digit: Disable UPC/EAN-13
Enable UPC/EAN-13
*0*
*1*
*0*
*1*
Enable UPC-A Only
*2* *2*
3. Scan one of these bar codes to set the second digit: Disable UPC-E
Enable UPC-E
*0*
*1*
*0*
*1*
4. Scan one of these bar codes to set the third digit: Disable EAN-8
Enable EAN-8
*0*
*1*
*0*
*1*
5. Scan one of these bar codes to set the fourth digit: Supplementals Not Allowed
Supplementals Allowed
*0*
*1*
*0*
12-98
*1*
Page 449
NF
BC Configuration Command Reference
12
6. (Optional) Scan one of these bar codes to set the fifth digit: Discard Check Digit
Transmit Check Digit
*0*
*1*
*0*
*1*
7. (Optional) Scan one of these bar codes to set the sixth digit: Discard Number System Digit
Transmit Number System Digit
*0*
*1*
*0*
*1*
Note: If you discard the number system digit, one leading digit is discarded from UPC-A, UPC-E, and EAN-8, and two leading digits are discarded from EAN-13. 8. (Optional) Scan one of these bar codes to set the seventh digit: Discard Leading Zero for UPC-A
Transmit Leading Zero for UPC-A
*0*
*1*
*0*
*1*
Note: This option applies only when you enable UPC-A/EAN-13. 9. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-99
Page 450
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Viewport Movement Keys Purpose:
Allows you to use the compound function and arrow keys to move the viewport around the virtual display. You must set the Display Setup command to 25 x 80 to use the reader’s viewport. For help, see “Display Setup” earlier in this chapter.
Default:
Enabled
Syntax:
DVdata Acceptable values for data are: 0 1
Scan:
Disable viewport movement keys Enable viewport movement keys
One of these bar codes: Disable Viewport Movement Keys
*$+DV0* *$+DV0*
Enable Viewport Movement Keys
*$+DV1* *$+DV1*
Viewport Movement Mode Purpose:
Enables Manual or Automatic Viewport Movement mode. In Manual mode, you manually move the viewport around the reader’s virtual display. In Automatic mode, the viewport automatically follows the cursor around the reader’s virtual display. You must set the Display Setup command to 25 x 80 to use the reader’s viewport. For help, see “Display Setup” earlier in this chapter. Note: While you run an application, the reader reverts to Automatic Viewport Movement mode and scrolls at line 25 unless your application sets these values. When you exit the application, the reader restores your previous configuration values.
Default:
12-100
Enable Automatic Viewport Movement mode