Page 431
NF
Scan:
BC Configuration Command Reference
12
To have all records transmitted in one block, scan this bar code: All Records = 1 Block
*$+FC0* *$+FC0*
Or:
To set the records per block: 1. Scan this bar code: Enter Accumulate Mode / Set Number of Records Per Block
*+/$+FC* *+/$+FC*
2. Scan a two-digit numeric value for data from these bar codes:
*0* *0*
*2*
*1* *1*
*3*
*2*
*3*
*4*
*5*
*4*
*6* *6*
*8* *8*
*5*
*7*
*7*
*9*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-81
Page 432
JANUS 2020 Hand-Held Computer User’s Manual NF BC
REQ (Request for Acknowledge) Purpose:
Enables or disables a request for a repeat handshake event. If you enable REQ, you must also enable AFF and NEG to have a valid configuration. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.
Default:
Disabled
Syntax:
PDdata where data can be any ASCII character.
Scan:
To disable REQ, scan this bar code: Disable REQ
*$+PD* *$+PD*
Or:
To set REQ to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set REQ
*+/$+PD* *+/$+PD*
2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-82
Page 433
NF
BC Configuration Command Reference
12
RES (Reset) Purpose:
Enables or disables a reset event. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.
Default:
Disabled
Syntax:
PCdata where data can be any ASCII character.
Scan:
To disable RES, scan this bar code: Disable RES
*$+PC* *$+PC*
Or:
To set RES to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set RES
*+/$+PC* *+/$+PC*
2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-83
Page 434
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Scan Ahead Purpose:
Enables or disables scan ahead. If you enable this parameter, you can scan a number of labels that are held in a stack until the reader can process the data. If you disable this parameter, the reader processes each label you scan before you can scan the next label.
Default:
Disabled
Syntax:
SDdata Acceptable values for data are: 0 1
Scan:
Disabled (scan one label at a time) Enabled (scan many labels at a time)
One of these bar codes: Disable Scan Ahead
*$+SD0* *$+SD0*
Enable Scan Ahead
*$+SD1* *$+SD1*
12-84
Page 435
NF
BC Configuration Command Reference
12
Scanner Mode Purpose:
Defines how the scanner operates when the trigger is pulled. There are two types of modes: •
One-Shot mode requires you to pull the trigger each time you want to scan a bar code. Once you scan a bar code, the scanner turns off.
•
Automatic mode allows you to pull the trigger once and scan a series of bar codes. When you release the trigger, the scanner turns off. To scan the same bar code more than once, you must release the trigger or scan a different bar code before attempting a second scan.
Default:
One-Shot mode
Syntax:
SBdata Acceptable values for data are: 0 1
Scan:
One-Shot mode Automatic mode
One of these bar codes: Enable One-Shot Mode
*$+SB0* *$+SB0*
Enable Automatic Mode
*$+SB1* *$+SB1*
12-85
Page 436
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Scanner Redundancy Purpose:
Defines the number of scans (voting) the scanner takes of the same label that must decode correctly for a good read of the label. Voting allows the reader to decode the same bar code multiple times during a single-trigger event, and to compare the decoded information a specific number of times before signaling a good read. There are three options: Low Allows the reader to accept the first good read, which speeds up reader performance. This setting is recommended when scanning good quality bar codes. Normal The reader decodes the bar code a minimum number of times in each trigger event. High The reader scans and decodes the bar code a maximum number of times in each trigger event. The specific number of comparisons depends on each bar code symbology. The high setting is recommended when scanning poor quality labels that may cause substitution errors. For example, when you scan Code 39 labels and the scanner redundancy is set to normal, two successive matching decodes in a single-trigger event are required. When scanner redundancy is set to high, three successive matching decodes in a single-trigger event are required.
Default:
Normal
Syntax:
SRdata Acceptable values for data are: 0 1 2
Scan:
None Normal High
One of these bar codes: None
*$+SR0* *$+SR0* High
*$+SR2* *$+SR2*
12-86
Normal
*$+SR1*
*$+SR1*
Page 437
NF
BC Configuration Command Reference
12
Scanner Timeout Purpose:
Defines the maximum length of time the scanner stays on following each trigger pull.
Default:
Disabled (no timeout)
Syntax:
SAdata Acceptable values for data are: 0 1-60
Scan:
Disabled Shutoff time in seconds
1. Scan this bar code: Enter Accumulate Mode / Change Scanner Timeout
*+/$+SA* *+/$+SA*
2. Scan a numeric value for data from these bar codes:
*0*
*1*
*2*
*3*
*0*
*1*
*2*
*3*
*4*
*5*
*4*
*6*
*5*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-87
Page 438
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Scanner Trigger Purpose:
Scanner trigger allows you to set level triggering or edge triggering. •
With level triggering, you pull the trigger and the laser turns on and stays on until you release the trigger.
•
In edge triggering, you pull the trigger and the laser turns on and stays on. When you pull the trigger a second time, the laser turns off. Simply releasing the trigger does not turn the laser off. If the laser is left on, the scanner timeout turns the laser off.
Default:
Level triggering
Syntax:
SCdata Acceptable values for data are: 0 1
Scan:
Level triggering Edge triggering
One of these bar codes: Enable Level Triggering
*$+SC0* *$+SC0*
Enable Edge Triggering
*$+SC1* *$+SC1*
12-88
Page 439
NF
BC Configuration Command Reference
12
SEL (Select) Purpose:
Defines the character that requests permission for the controller to send data to the polled device. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.
Default:
Disabled
Syntax:
HAdata where data can be any ASCII character.
Scan:
To disable SEL, scan this bar code: Disable SEL
*$+HA* *$+HA*
Or:
To set SEL to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set SEL
*+/$+HA* *+/$+HA*
2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-89
Page 440
JANUS 2020 Hand-Held Computer User’s Manual NF BC
SOM (Start of Message) Purpose:
SOM is the first character in a message sent to or received from the host computer. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.
Default:
Disabled
Syntax:
PEdata where data can be any ASCII character.
Scan:
To disable SOM, scan this bar code: Disable SOM
*$+PE* *$+PE*
Or:
To set SOM to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set SOM
*+/$+PE* *+/$+PE*
2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-90