JANUS 2020 Hand-Held Computer User's Manual, pages 461 to 470

Pages 461 to 470 of 570

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec J2020 and Intermec JR2020

Page 461

NF

BC Reader Specifications

A

Operations Parameter

Default

Automatic Shutoff

1 minute

Beep Duration

50 milliseconds for low and high beep

Beep Frequency

1000 Hz for low beep, 2000 Hz for high beep

Beep Volume

Normal

Command Processing

All reader commands enabled

Decode Security

Moderate

Display Backlight Timeout

10 seconds

Display Contrast

3 (maximum contrast)

Display Mode, IRL

Buffered

Display Setup

25 x 80, Video mode 3, scroll at line 16, normal character height

Key Code Look-Up Table

102-key PC keyboard (no modifications)

Keypad Caps Lock

Caps lock off

Keypad Clicker

Enabled

Keypad Ctrl Key Functions

All Ctrl functions enabled

Keypad, Numeric

Permit entering numeric keypad

Postamble

<CR>

Preamble

Disabled

Scan Ahead

Disabled

Scanner Mode

One-Shot mode

Scanner Redundancy

Normal

Scanner Timeout

Disabled (no timeout)

Scanner Trigger

Level triggering

Viewport Movement Keys

Enabled

Viewport Movement Mode

Automatically follow the cursor

Viewport Movement Steps

10 horizontal steps and 9 vertical steps

A-9

Page 462

JANUS 2020 Hand-Held Computer User’s Manual NF BC

900 MHz RF Communications Parameter

Default

Acknowledgment Delay

100 milliseconds

Broadcast Receipt

Enabled

Channel Allow

All channels are excluded from the search pattern.

Channel Select

924 MHz

Device Address

0 (turned off)

Duty Cycle Percent

30%

Duty Cycle Period

1 second

Loopback

Disabled

Network ID

Channel search disabled

Repeat Count

0 (no repeaters)

Retry Limit

0 (optimized setting)

RF Protocol

Enabled

RFNC Address (RF Network Controller)

RFNC 0

Note: For help on the RF configuration commands, see the JANUS 900 MHz Radio Frequency Quick Reference Guide (Part No. 060207).

A-10

Page 463

NF

BC Reader Specifications

A

Configuration Commands by Syntax The next table lists all of the configuration commands that are available on the J2020 and JR2020 readers. It lists the configuration commands in alphabetic order by syntax. Note: For help on the RF configuration commands, see the JANUS 900 MHz Radio Frequency Quick Reference Guide (Part No. 060207). Syntax

Command

For Help, See Page

ADdata

Preamble

12-79

AEdata

Postamble

12-78

BDdata

Beep Duration

12-12

BFdata

Beep Frequency

12-13

BVdata

Beep Volume

12-15

CAdata

Interleaved 2 of 5 Code (I 2 of 5)

12-58

CBdata

Code 39

12-21

CCdata

Code 2 of 5 (2 of 5)

12-19

CDdata

Codabar

12-16

CEdata

UPC/EAN

12-97

CFdata

Code 93

12-27

CGdata

Code 11

12-17

CHdata

Code 128

12-28

CIdata

Plessey

12-76

CJdata

Code 49

12-25

CKdata

Code 49 Function Code 1

12-25

CLdata

Code 49 Function Code 2

12-25

CMdata

Code 49 Function Code 3

12-25

CNdata

MSI

12-72

CPdata

Code 16K

12-18

CSdata

Decode Security

12-44

DCdata

Command Processing

12-29

DFdata

Display Backlight Timeout

12-44

DJdata

Display Contrast

12-46

DMdata

Display Mode, IRL

12-47

A-11

Page 464

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Configuration Commands by Syntax (continued) Syntax

Command

For Help, See Page

DSdata

Display Setup

12-48

DVdata

Viewport Movement Keys

12-100

DYdata

Viewport Movement Steps

12-101

DZdata

Viewport Movement Mode

12-100

EZdata

Automatic Shutoff

12-9

FAdata

EOF (End of File)

12-52

FBdata

EOR (End of Record)

12-55

FCdata

Records Per Block

12-80

HAdata

SEL (Select)

12-89

HBdata

POL

12-77

HCdata

Address, Multi-Drop

12-7

IAdata

Baud Rate

12-10

IBdata

Parity

12-75

ICdata

Stop Bits

12-91

IDdata

Intercharacter Delay

12-57

IEdata

Timeout Delay

12-92

IFdata

LRC (Longitudinal Redundancy Check)

12-72

IGdata

Turnaround Delay

12-96

IHdata

Transmit Abort Timeout

12-94

IIdata

Data Bits

12-43

ILdata

Flow Control

12-56

IPdata

Communications Dock Port

12-35

ISdata

Communications Port, Select COM Port

12-36

IVdata

Communications Port, UART Restore

12-37

KAdata

Keypad Caps Lock

12-68

KBdata

Keypad Ctrl Key Functions

12-70

KCdata

Keypad Clicker

12-69

KDdata

Keypad, Numeric

12-71

NM02data

RF Loopback

See RF guide

NM03data

RF Broadcast Receipt

See RF guide

A-12

Page 465

NF

BC Reader Specifications

A

Configuration Commands by Syntax (continued) Syntax

Command

For Help, See Page

PAdata

Communications Protocol, Activate

12-41

PCdata

RES (Reset)

12-83

PDdata

REQ (Request for Acknowledge)

12-82

PEdata

SOM (Start of Message)

12-90

PFdata

EOM (End of Message)

12-53

PGdata

AFF (Affirmative Acknowledge)

12-8

PHdata

NEG (Negative Acknowledge)

12-74

PIdata

Transmit EOM (End of Message) Only

12-53

PJdata

Receive EOM (End of Message) Only

12-53

PMdata

Communications Protocol, User-Defined Multi-Drop

12-42

PSdata

Communications Protocol, Configure

12-38

Rchannel data

RF Channel Allow

See RF guide

RFdata

RF Protocol

See RF guide

RHdata

RF Device Address

See RF guide

RLdata

RF Retry Limit

See RF guide

RMdata

RF Acknowledgment Delay

See RF guide

RTdata

RFNC (RF Network Controller) Address

See RF guide

RUdata

RF Repeat Count

See RF guide

RVdata

RF Channel Select

See RF guide

RWdata

RF Network ID

See RF guide

RXdata

RF Duty Cycle Period

See RF guide

RYdata

RF Duty Cycle Percent

See RF guide

SAdata

Scanner Timeout

12-87

SBdata

Scanner Mode

12-85

SCdata

Scanner Trigger

12-88

SDdata

Scan Ahead

12-84

SRdata

Scanner Redundancy

12-86

WMdata

Key Code Look-Up Table

12-67

XAdata

IRL SOP (Start of Program)

12-66

XBdata

IRL EOP (End of Program)

12-62

A-13

Page 466

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Configuration Commands by Syntax (continued) Syntax

Command

For Help, See Page

XCdata

IRL Run

12-65

XDdata

IRL End Program Block

12-61

XEdata

IRL PSS (Program Statement Separator)

12-64

ZAdata

IRL PAK (Program Acknowledge)

12-63

ZBdata

IRL BAK (Bad Program Acknowledge)

12-60

A-14

Page 467

NF

BC Reader Specifications

A

Types of Memory Used in the Reader The JANUS reader uses the types of memory described in this section. Memory in the reader is similar to that of a PC in some ways, and very different in other ways. One major difference is that the reader uses memory to simulate disk drives. This memory map shows how the reader uses memory.

15FFFF End of extended memory

Physical RAM drive

320K -64K 256K

384K

Drive E

DFFFFF End of application flash

Drive D 64K

0E0000 - 0FFFFF BIOS and BIOS extensions

128K

0D0000 - 0DFFFF ROM DOS

64K

0C0000 - 0CFFFF PC card memory

64K

0B8000 - 0BFFFF CGA video memory

32K

0A0000 - 0B7FFF Not used 09FFFF End of conventional memory

96K

384K Upper Memory Area

100000 - 10FFFF Extended memory/ High Memory Area (HMA)

2MB

Application flash

80K

880000 - BFFFFF No memory

640K

640K Conventional memory

638K User

00500 - 005FF (256 bytes) DOS and Basic use 00400 - 004FF (256 bytes) BIOS data 00300 - 003FF (256 bytes) BIOS stack/user vectors 001E0 - 002FF (256 bytes) User vectors 00000 - 001DF (480 bytes) Interrupt vectors

C14000 Start of application flash C00000 - C13FFF ROM DOS

87FFFF End of user flash

Drive C 512K

User flash

800000 Start of user flash 160000 - 79FFFF No memory

000000 Beginning of conventional memory 2020U.016

A-15

Page 468

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Conventional Memory (0 Through 640K) The reader has 1MB of battery-backed dynamic RAM. The first 640K is conventional memory and is virtually the same as that of a PC. You can use this memory to run applications. The ROM DOS 5.0 operating system loads at 0 and works up, followed by the statements and drivers in the CONFIG.SYS file, then COMMAND.COM, TSR (terminate and stay resident) programs, and commands in the AUTOEXEC.BAT file.

Upper Memory Area The area between the 640K and 1024K is known as the upper memory area. The upper memory area is physically composed of a 256K flash ROM chip (system flash) and the video memory chip. Like a PC, this area contains the BIOS and video buffers. On the reader, the upper memory area also contains PC card memory and ROM DOS. The 384K upper memory area maps just above 640K conventional memory.

Rolled-Over Memory The reader has 1MB of battery-backed DRAM. From the memory existing between the 640K and 1MB boundaries, 384K is remapped or “rolled-over” above 1MB to create the RAM drive. If you do not need the RAM drive, you can access rolled-over memory as extended memory through a device driver or an application that uses HIMEM.SYS.

RAM Drive Part of rolled-over memory is configured as a RAM drive (drive E) on the JANUS reader. The default CONFIG.SYS file loads HIMEM.SYS and uses the SRAMDISK.SYS device driver to create the RAM drive. You can use the RAM drive to store files just like a disk drive on your PC. File access is usually faster on a RAM drive than a physical disk drive. Unlike a PC, any files on the RAM drive are saved during a warm boot. However, any files on the RAM drive are cleared when you cold boot the reader. The reader requires 64K of the rolled-over memory area for the high memory area (HMA) and another 64K is used as extended memory, leaving a maximum of 256K available to store files. If you are not using a PC card, Intermec recommends that you use the RAM drive for data files that are stored frequently. The RAM drive is not as secure as a PC card since the drive is erased when you cold boot the reader.

A-16

Page 469

NF

BC Reader Specifications

A

Extended Memory The reader is initially configured with 64K of extended memory available, which is allocated for use by Intermec applications (IC.EXE and IRL). To remove the RAM drive and use the available extended memory, you need to change or delete the SRAMDISK statement in the CONFIG.SYS file. You can also use extended memory for overlay memory. The reader provides extended memory for control and access to RAM above 1MB. The extended memory conforms to XMS specification 2.0. Extended memory is initialized and managed by the HIMEM.SYS driver. HIMEM.SYS looks at all the memory in the system and takes control of everything above 1024K. You must load all drivers in extended memory through the HIMEM.SYS interface. If a driver is not compatible with HIMEM.SYS, you cannot load it. Some applications may require you to exclude memory from HIMEM.SYS management, leaving some extended memory available. If this is necessary, you should reconfigure the RAM drive (E) to use the available extended memory. DOS drivers must check in with HIMEM.SYS for their memory assignments within the XMS managed by HIMEM.SYS. Currently, the RAM drive uses the XMS interface through HIMEM.SYS.

Expanded Memory Once more than 1MB of memory is installed on a PC, it can be used as expanded memory and is a way for the system to access memory beyond the 1MB barrier. To use expanded memory on a PC, you need an expanded memory board and an expanded memory manager. Expanded memory is not available on the JANUS reader.

High Memory Area (HMA) The high memory area (HMA) is a 64K block of memory, starting 16 bytes below the 1024K mark, and is the first 64K of extended memory. Since HMA can only hold one item, the first program that requests HMA uses it, regardless of the size of the program. You cannot use the statement DOS=HIGH on the reader because DOS already resides in ROM in an upper memory block. Note: The HMA is used by Reader Services. If HIMEM.SYS is not loaded or if HMA is being used by another driver, Reader Services is not loaded and the JANUS 2020 does not function as a bar code reader.

A-17

Page 470

JANUS 2020 Hand-Held Computer User’s Manual NF BC

User Flash Memory User flash memory contains the 512K ROM drive C. It is mapped to 800000H. The reader’s drive C is similar to the hard drive C on your PC and contains the startup files, CONFIG.SYS and AUTOEXEC.BAT. Since drive C is a ROM drive that resides in flash memory, you cannot write files to this drive as you would on your PC. You must use the Auto-Loader or MkImage and PutImage to modify the startup files or change other files on drive C. For help, see Chapter 3, “Learning About the Software.”

Application Flash Memory Application flash memory is the 2MB ROM drive D. It is mapped to C00000H. DOS files and utilities are stored on drive D. You cannot modify or add files to drive D. The reader uses approximately 80K of the application flash memory for ROM DOS leaving a 1.943MB ROM drive D.

A-18