The text of a manual · part 47 of 57
JANUS 2020 Hand-Held Computer User's Manual, pages 461 to 470
Pages 461 to 470 of 570
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2020 and Intermec JR2020
Page 461
NF
BC Reader Specifications
A
Operations Parameter
Default
Automatic Shutoff
1 minute
Beep Duration
50 milliseconds for low and high beep
Beep Frequency
1000 Hz for low beep, 2000 Hz for high beep
Beep Volume
Normal
Command Processing
All reader commands enabled
Decode Security
Moderate
Display Backlight Timeout
10 seconds
Display Contrast
3 (maximum contrast)
Display Mode, IRL
Buffered
Display Setup
25 x 80, Video mode 3, scroll at line 16, normal character height
Key Code Look-Up Table
102-key PC keyboard (no modifications)
Keypad Caps Lock
Caps lock off
Keypad Clicker
Enabled
Keypad Ctrl Key Functions
All Ctrl functions enabled
Keypad, Numeric
Permit entering numeric keypad
Postamble
<CR>
Preamble
Disabled
Scan Ahead
Disabled
Scanner Mode
One-Shot mode
Scanner Redundancy
Normal
Scanner Timeout
Disabled (no timeout)
Scanner Trigger
Level triggering
Viewport Movement Keys
Enabled
Viewport Movement Mode
Automatically follow the cursor
Viewport Movement Steps
10 horizontal steps and 9 vertical steps
A-9
Page 462
JANUS 2020 Hand-Held Computer User’s Manual NF BC
900 MHz RF Communications Parameter
Default
Acknowledgment Delay
100 milliseconds
Broadcast Receipt
Enabled
Channel Allow
All channels are excluded from the search pattern.
Channel Select
924 MHz
Device Address
0 (turned off)
Duty Cycle Percent
30%
Duty Cycle Period
1 second
Loopback
Disabled
Network ID
Channel search disabled
Repeat Count
0 (no repeaters)
Retry Limit
0 (optimized setting)
RF Protocol
Enabled
RFNC Address (RF Network Controller)
RFNC 0
Note: For help on the RF configuration commands, see the JANUS 900 MHz Radio Frequency Quick Reference Guide (Part No. 060207).
A-10
Page 463
NF
BC Reader Specifications
A
Configuration Commands by Syntax The next table lists all of the configuration commands that are available on the J2020 and JR2020 readers. It lists the configuration commands in alphabetic order by syntax. Note: For help on the RF configuration commands, see the JANUS 900 MHz Radio Frequency Quick Reference Guide (Part No. 060207). Syntax
Command
For Help, See Page
ADdata
Preamble
12-79
AEdata
Postamble
12-78
BDdata
Beep Duration
12-12
BFdata
Beep Frequency
12-13
BVdata
Beep Volume
12-15
CAdata
Interleaved 2 of 5 Code (I 2 of 5)
12-58
CBdata
Code 39
12-21
CCdata
Code 2 of 5 (2 of 5)
12-19
CDdata
Codabar
12-16
CEdata
UPC/EAN
12-97
CFdata
Code 93
12-27
CGdata
Code 11
12-17
CHdata
Code 128
12-28
CIdata
Plessey
12-76
CJdata
Code 49
12-25
CKdata
Code 49 Function Code 1
12-25
CLdata
Code 49 Function Code 2
12-25
CMdata
Code 49 Function Code 3
12-25
CNdata
MSI
12-72
CPdata
Code 16K
12-18
CSdata
Decode Security
12-44
DCdata
Command Processing
12-29
DFdata
Display Backlight Timeout
12-44
DJdata
Display Contrast
12-46
DMdata
Display Mode, IRL
12-47
A-11
Page 464
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Configuration Commands by Syntax (continued) Syntax
Command
For Help, See Page
DSdata
Display Setup
12-48
DVdata
Viewport Movement Keys
12-100
DYdata
Viewport Movement Steps
12-101
DZdata
Viewport Movement Mode
12-100
EZdata
Automatic Shutoff
12-9
FAdata
EOF (End of File)
12-52
FBdata
EOR (End of Record)
12-55
FCdata
Records Per Block
12-80
HAdata
SEL (Select)
12-89
HBdata
POL
12-77
HCdata
Address, Multi-Drop
12-7
IAdata
Baud Rate
12-10
IBdata
Parity
12-75
ICdata
Stop Bits
12-91
IDdata
Intercharacter Delay
12-57
IEdata
Timeout Delay
12-92
IFdata
LRC (Longitudinal Redundancy Check)
12-72
IGdata
Turnaround Delay
12-96
IHdata
Transmit Abort Timeout
12-94
IIdata
Data Bits
12-43
ILdata
Flow Control
12-56
IPdata
Communications Dock Port
12-35
ISdata
Communications Port, Select COM Port
12-36
IVdata
Communications Port, UART Restore
12-37
KAdata
Keypad Caps Lock
12-68
KBdata
Keypad Ctrl Key Functions
12-70
KCdata
Keypad Clicker
12-69
KDdata
Keypad, Numeric
12-71
NM02data
RF Loopback
See RF guide
NM03data
RF Broadcast Receipt
See RF guide
A-12
Page 465
NF
BC Reader Specifications
A
Configuration Commands by Syntax (continued) Syntax
Command
For Help, See Page
PAdata
Communications Protocol, Activate
12-41
PCdata
RES (Reset)
12-83
PDdata
REQ (Request for Acknowledge)
12-82
PEdata
SOM (Start of Message)
12-90
PFdata
EOM (End of Message)
12-53
PGdata
AFF (Affirmative Acknowledge)
12-8
PHdata
NEG (Negative Acknowledge)
12-74
PIdata
Transmit EOM (End of Message) Only
12-53
PJdata
Receive EOM (End of Message) Only
12-53
PMdata
Communications Protocol, User-Defined Multi-Drop
12-42
PSdata
Communications Protocol, Configure
12-38
Rchannel data
RF Channel Allow
See RF guide
RFdata
RF Protocol
See RF guide
RHdata
RF Device Address
See RF guide
RLdata
RF Retry Limit
See RF guide
RMdata
RF Acknowledgment Delay
See RF guide
RTdata
RFNC (RF Network Controller) Address
See RF guide
RUdata
RF Repeat Count
See RF guide
RVdata
RF Channel Select
See RF guide
RWdata
RF Network ID
See RF guide
RXdata
RF Duty Cycle Period
See RF guide
RYdata
RF Duty Cycle Percent
See RF guide
SAdata
Scanner Timeout
12-87
SBdata
Scanner Mode
12-85
SCdata
Scanner Trigger
12-88
SDdata
Scan Ahead
12-84
SRdata
Scanner Redundancy
12-86
WMdata
Key Code Look-Up Table
12-67
XAdata
IRL SOP (Start of Program)
12-66
XBdata
IRL EOP (End of Program)
12-62
A-13
Page 466
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Configuration Commands by Syntax (continued) Syntax
Command
For Help, See Page
XCdata
IRL Run
12-65
XDdata
IRL End Program Block
12-61
XEdata
IRL PSS (Program Statement Separator)
12-64
ZAdata
IRL PAK (Program Acknowledge)
12-63
ZBdata
IRL BAK (Bad Program Acknowledge)
12-60
A-14
Page 467
NF
BC Reader Specifications
A
Types of Memory Used in the Reader The JANUS reader uses the types of memory described in this section. Memory in the reader is similar to that of a PC in some ways, and very different in other ways. One major difference is that the reader uses memory to simulate disk drives. This memory map shows how the reader uses memory.
15FFFF End of extended memory
Physical RAM drive
320K -64K 256K
384K
Drive E
DFFFFF End of application flash
Drive D 64K
0E0000 - 0FFFFF BIOS and BIOS extensions
128K
0D0000 - 0DFFFF ROM DOS
64K
0C0000 - 0CFFFF PC card memory
64K
0B8000 - 0BFFFF CGA video memory
32K
0A0000 - 0B7FFF Not used 09FFFF End of conventional memory
96K
384K Upper Memory Area
100000 - 10FFFF Extended memory/ High Memory Area (HMA)
2MB
Application flash
80K
880000 - BFFFFF No memory
640K
640K Conventional memory
638K User
00500 - 005FF (256 bytes) DOS and Basic use 00400 - 004FF (256 bytes) BIOS data 00300 - 003FF (256 bytes) BIOS stack/user vectors 001E0 - 002FF (256 bytes) User vectors 00000 - 001DF (480 bytes) Interrupt vectors
C14000 Start of application flash C00000 - C13FFF ROM DOS
87FFFF End of user flash
Drive C 512K
User flash
800000 Start of user flash 160000 - 79FFFF No memory
000000 Beginning of conventional memory 2020U.016
A-15
Page 468
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Conventional Memory (0 Through 640K) The reader has 1MB of battery-backed dynamic RAM. The first 640K is conventional memory and is virtually the same as that of a PC. You can use this memory to run applications. The ROM DOS 5.0 operating system loads at 0 and works up, followed by the statements and drivers in the CONFIG.SYS file, then COMMAND.COM, TSR (terminate and stay resident) programs, and commands in the AUTOEXEC.BAT file.
Upper Memory Area The area between the 640K and 1024K is known as the upper memory area. The upper memory area is physically composed of a 256K flash ROM chip (system flash) and the video memory chip. Like a PC, this area contains the BIOS and video buffers. On the reader, the upper memory area also contains PC card memory and ROM DOS. The 384K upper memory area maps just above 640K conventional memory.
Rolled-Over Memory The reader has 1MB of battery-backed DRAM. From the memory existing between the 640K and 1MB boundaries, 384K is remapped or “rolled-over” above 1MB to create the RAM drive. If you do not need the RAM drive, you can access rolled-over memory as extended memory through a device driver or an application that uses HIMEM.SYS.
RAM Drive Part of rolled-over memory is configured as a RAM drive (drive E) on the JANUS reader. The default CONFIG.SYS file loads HIMEM.SYS and uses the SRAMDISK.SYS device driver to create the RAM drive. You can use the RAM drive to store files just like a disk drive on your PC. File access is usually faster on a RAM drive than a physical disk drive. Unlike a PC, any files on the RAM drive are saved during a warm boot. However, any files on the RAM drive are cleared when you cold boot the reader. The reader requires 64K of the rolled-over memory area for the high memory area (HMA) and another 64K is used as extended memory, leaving a maximum of 256K available to store files. If you are not using a PC card, Intermec recommends that you use the RAM drive for data files that are stored frequently. The RAM drive is not as secure as a PC card since the drive is erased when you cold boot the reader.
A-16
Page 469
NF
BC Reader Specifications
A
Extended Memory The reader is initially configured with 64K of extended memory available, which is allocated for use by Intermec applications (IC.EXE and IRL). To remove the RAM drive and use the available extended memory, you need to change or delete the SRAMDISK statement in the CONFIG.SYS file. You can also use extended memory for overlay memory. The reader provides extended memory for control and access to RAM above 1MB. The extended memory conforms to XMS specification 2.0. Extended memory is initialized and managed by the HIMEM.SYS driver. HIMEM.SYS looks at all the memory in the system and takes control of everything above 1024K. You must load all drivers in extended memory through the HIMEM.SYS interface. If a driver is not compatible with HIMEM.SYS, you cannot load it. Some applications may require you to exclude memory from HIMEM.SYS management, leaving some extended memory available. If this is necessary, you should reconfigure the RAM drive (E) to use the available extended memory. DOS drivers must check in with HIMEM.SYS for their memory assignments within the XMS managed by HIMEM.SYS. Currently, the RAM drive uses the XMS interface through HIMEM.SYS.
Expanded Memory Once more than 1MB of memory is installed on a PC, it can be used as expanded memory and is a way for the system to access memory beyond the 1MB barrier. To use expanded memory on a PC, you need an expanded memory board and an expanded memory manager. Expanded memory is not available on the JANUS reader.
High Memory Area (HMA) The high memory area (HMA) is a 64K block of memory, starting 16 bytes below the 1024K mark, and is the first 64K of extended memory. Since HMA can only hold one item, the first program that requests HMA uses it, regardless of the size of the program. You cannot use the statement DOS=HIGH on the reader because DOS already resides in ROM in an upper memory block. Note: The HMA is used by Reader Services. If HIMEM.SYS is not loaded or if HMA is being used by another driver, Reader Services is not loaded and the JANUS 2020 does not function as a bar code reader.
A-17
Page 470
JANUS 2020 Hand-Held Computer User’s Manual NF BC
User Flash Memory User flash memory contains the 512K ROM drive C. It is mapped to 800000H. The reader’s drive C is similar to the hard drive C on your PC and contains the startup files, CONFIG.SYS and AUTOEXEC.BAT. Since drive C is a ROM drive that resides in flash memory, you cannot write files to this drive as you would on your PC. You must use the Auto-Loader or MkImage and PutImage to modify the startup files or change other files on drive C. For help, see Chapter 3, “Learning About the Software.”
Application Flash Memory Application flash memory is the 2MB ROM drive D. It is mapped to C00000H. DOS files and utilities are stored on drive D. You cannot modify or add files to drive D. The reader uses approximately 80K of the application flash memory for ROM DOS leaving a 1.943MB ROM drive D.
A-18