The text of a manual · part 32 of 57

JANUS 2020 Hand-Held Computer User's Manual, pages 311 to 320

Pages 311 to 320 of 570

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec J2020 and Intermec JR2020

Page 311

NF

BC Troubleshooting

10

Running IRL Programs e

When an IRL error occurs, the reader beeps and displays an error message. Press to clear the message and continue. The types of error messages are: Receive error This error occurs when the reader is receiving a message or protocol characters from the host. Transmit error This error occurs when the reader is transmitting a message or protocol characters to the host. Syntax error This error occurs when the reader is performing a syntax check on a program before running the program. If a program statement is invalid, the error message lists the program statement and the problem. Edit the program for syntax errors and run it again. Runtime error This error occurs when the reader is executing a program. The program ignores nonfatal errors. If it is a fatal error, the reader exits the program and returns to the IRL Desktop or DOS prompt. This table lists the error beep sequences and their meanings: Sequence

Meaning

Three low beeps

Syntax or compile error

Low beep, high beep, low beep

Nonfatal runtime error

Three high beeps

Fatal runtime error

Note: The JANUS reader does not beep to indicate transmit or receive errors. The next table lists problems that may occur when you run IRL programs on the reader. Problem

Solution

The reader displays “Executing...” on power up or prompts you for data on power up.

An IRL Program is running. Type or scan this Exit IRL Program command: Exit IRL Program

*/$* */$*

There is not enough memory to run your IRL program.

You need to free more conventional memory or run the program without running the IRL Desktop. For help, see “Freeing Enough Memory to Run an IRL Program” in Chapter 7.

10-15

Page 312

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Running IRL Programs (continued) Problem

Solution

When you try to start the IRL Desktop, the reader displays an error message indicating that there is not enough memory available to run the Configuration Manager.

If the Configuration Manager TSR is unloaded when you start the IRL Desktop, the reader automatically loads the TSR for you. If there is not enough conventional memory available for the Configuration Manager TSR, the reader displays an error message. Make sure at least 50K of memory is available.

The reader is locked up in an IRL program.

Perform the application break sequence, as described in “Breaking Out of an Application” in Chapter 9.

You are having problems trying to download an IRL program.

Make sure you have performed all these steps: • You configured the communications protocol correctly on the reader and host. For help, see “Configuring the Communications Protocols” in Chapter 6. • You activated the communications protocol. For help, see “Activating One Communications Protocol” in Chapter 6. • You loaded the protocol handler. For help, see “Loading and Unloading a Protocol Handler” in Chapter 6. • You are in the IRL Desktop, at the main menu, with no commands selected. You have trouble running an IRL program with Interlnk.

10-16

You cannot run an IRL program over an Interlnk connection.

Page 313

NF

BC Troubleshooting

10

Using PC Cards This table lists problems that may occur when you use PC cards in the JANUS reader. For help, see Chapter 4, “Using PC Cards in the Reader.” Problem

Solution

You are trying to access the reader’s PC card drive and you see the message, “Invalid media type reading drive X. Abort, Retry, Fail?”

Press to abort. The reader cannot read the PC card in the drive. Use the CARDINFO utility to verify the type of card you are using (ATA, flash, I/O, or SRAM).

You are trying to access the reader’s PC card drive and you see the message, “Not ready reading drive X. Abort, Retry, Fail?”

Press to try again. If you see the message again, press to abort. The reader cannot read the PC card in the drive. Use the CARDINFO utility to verify the type of card you are using (ATA, flash, I/O, or SRAM).

A

Check the reader’s CONFIG.SYS file. Make sure you have the correct drivers installed for the type of card you are using. Format the PC card.

R

A

Check the reader’s CONFIG.SYS file. Make sure you have the correct drivers installed for the type of card you are using. Format the PC card. You may also see this message if you are using the Substitute command and you do not have a PC card in each PC card drive. Insert a PC card in each drive and try using the Substitute command again. You try to access the reader’s PC card drive and you see the message, “Bad command or file.”

Check the command you entered and make sure it is a valid command. Try entering the command again.

You access the PC card in the PC card drive and the reader locks up frequently.

The PC card may not be formatted correctly. If you formatted the PC card on your PC or host computer, try formatting the card in the reader’s PC card drive. You can also use the CARDINFO utility to verify the current format and status of the card.

You try to load CS_APM.EXE or CS_IPM.EXE and you see the message, “CS PM already loaded.”

You cannot load CS_APM and CS_IPM at the same time. If you see this message, one of the utilities is already loaded. Load CS_APM only for I/O cards; otherwise use CS_IPM. Check the AUTOEXEC.BAT file to see which utility is loaded. If you are loading the wrong one, edit the AUTOEXEC.BAT file or load the utility from the DOS prompt. For help, see “Drivers in AUTOEXEC.BAT” in Chapter 4.

10-17

Page 314

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Using PC Cards (continued) Problem

Solution

You hear the reader sound a single low tone beep when you insert a PC card in the PC card drive.

The reader cannot read the card in the PC card drive. You need to format the card. For help, see “Configuring, Formatting, and Using PC Cards” in Chapter 4. If you followed all the instructions to format a flash PC card and the reader still does not recognize the card, you may need to install two other flash card drivers. You need to install the MTAA.EXE and MTAB.EXE drivers to use AMD Type A or B flash cards. Copy the two drivers from the Application companion disk 3 to drive C on the reader (using Auto-Loader or MkImage and PutImage). Edit the CONFIG.SYS file and add these lines after the line that installs the MTI2P.EXE driver: device=c:\mtaa.exe device=c:\mtab.exe After you place the revised CONFIG.SYS file on the reader’s drive C, boot the reader and try to format the flash card again.

You delete files from a 512K flash card and it does not appear that there is any additional space available on the card.

If you are using a 512K flash card with an MS-Flash file format, the card is formatted as a WORM (Write Once Read Many) drive. A 512K flash card does not have room for more than one separately erasable block of memory. You can delete individual files using the DOS delete command, but the memory the files were using is not available to be used again. To reclaim the memory from deleted files, you need to erase the entire card and then reformat the card. Note: Intermec recommends using flash cards that store 1MB or more of data.

You try to format a flash PC card with the MCFORMAT utility and you see the message, “You must erase X: before creating a new partition.”

If a flash card has been formatted before, you must erase the card before you can format it. Use the MCFORMAT utility and select option from the MCFORMAT main menu to erase a flash card.

3

If you erase the flash card and still see this message when you try to format the card or the card will not format, check CONFIG.SYS. Make sure the flash card drivers are installed. Once the flash card drivers are active in CONFIG.SYS, try erasing the flash card. Then format the card.

10-18

Page 315

NF

BC Troubleshooting

10

Using PC Cards (continued) Problem

Solution

After you load your Novell network software, you use a network PC card and run an application that does not work properly after making a system call.

Your Novell network software may have modified the COMSPEC environment variable to add a drive specifier to the path. However, DOS needs COMSPEC to find the COMMAND.COM file, which must be loaded for DOS to execute system commands. The reader uses ROM DOS, which expects COMSPEC to be set to: comspec=command To eliminate this problem, run the INITENV utility before you log onto a NetWare server. INITENV.EXE is on the reader’s drive C and Application companion disk 3. Create a login batch file similar to this one: @echo off c:\initenv e:\login %1 %2 set comspec=command Use the new login file instead of your Novell login file when you log the reader onto the server. If you do not run INITENV.EXE before logging in, your DOS environment table will be corrupted and cause your JANUS application to fail. You can set COMSPEC correctly to fix part of the problem, but you must boot the reader to clear embedded garbage characters from the environment table.

e

To check COMSPEC, type set and press . All environment variables are displayed. If COMSPEC was set to anything other than COMMAND, it has been changed by the login process.

10-19

Page 316

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Using DOS Commands and Applications This table lists problems that may occur when you run DOS-based applications on the reader. Problem

Solution

The reader displays a “Write Fault Error Writing Device PRN” message.

A <DLE> or Ctrl-P was entered into the reader. There may be a conflict because <DLE> is both the Intermec command override command and the DOS printer redirection command. Press to turn off console echo to the printer and then press to abort. For help, see “Command Override” in Chapter 11.

The reader is locked up in an application.

Perform the application break sequence, as described in “Breaking Out of an Application” in Chapter 9.

There is not enough memory to load a program.

You need to free conventional memory. For help, see “Making More Memory Available on the Reader” in Chapter 3.

The reader locks up when running AutoLoader and you cannot reboot the reader.

Use the Boot Loader menu to reload the system flash memory. For help, see “Loading Flash Memory” in Chapter 9.

You have trouble running an IRL program over an Interlnk connection.

You cannot run an IRL program over an Interlnk connection.

You do not have MS-DOS Programs companion disk 2 and need to use Interlnk.

If you do not have companion disk 2, which contains the Interlnk files, you can install Interlnk to the host from the reader.

cP

A

Connect the reader and host computer with a 7-wire RS-232 cable when installing Interlnk. The MODE command must be available on the host where you are installing Interlnk. Type this command on the reader: intersvr /rcopy The command copies the Interlnk files to the host computer. The host computer locks up after you type this command on the reader:

When the Interlnk files are downloaded to the host computer, the host computer may lock up. Reboot the host computer.

intersvr /rcopy The reader locks up when you are using Interlnk and try to get a directory listing (DIR) on one of the reader’s ROM drives.

10-20

Edit the host computer’s AUTOEXEC.BAT or CONFIG.SYS file and remove or remark out Windows SMARTDRV.EXE.

Page 317

NF

BC Troubleshooting

10

Using DOS Commands and Applications (continued) Problem

Solution

The reader locks up just after the DOS boot banner message appears when you finish updating drive C with Auto-Loader.

Press Alt-F4 on the host computer and then warm boot the reader. A lockup occurs when both these conditions are true: • An active Intersvr connection to the JANUS reader exists when the reader reboots. The reader’s default CONFIG.SYS file installs Interlnk automatically when the reader is connected to COM1 of the host computer and the host is running Intersvr. • The reader’s CONFIG.SYS and AUTOEXEC.BAT install a combination of device drivers, DOS options, TSRs, and applications that absorb the majority of available conventional memory. When both conditions exist, there is not enough space for your software configuration to coexist with the Interlnk device driver. The reader attempts to allocate memory that is not available, and a lockup may occur. To prevent the lockup, press Alt-F4 on the host computer or break the serial connection between the reader and host computer before the reader reaches the DOS initialization step of the warm boot. When you exit Intersvr on the host computer or break the serial connection, the Interlnk device driver will not detect INTERSVR.EXE, and Interlnk will not be loaded into the reader’s memory.

A DOS command does not work.

These DOS commands are not supported on the reader: DOSSHELL.* DOSSWAP.EXE DRIVER.SYS EGA.* EGAMONO.GRB FDISK.EXE GORILLA.BAS HERC.*

You cannot access a drive while using Interlnk.

MONEY.BAS MONO.* MSHER.COM NIBBLE.BAS REMLINE.BAS UNFORMAT.COM VGA.* VGAMONO.GRB

Interlnk does not redirect network drives, CD-ROM drives, or any other device that uses a redirection interface. These commands do not work with Interlnk: CHKDSK DISKCOMP DISKCOPY FORMAT

MIRROR SYS UNDELETE UNFORMAT

10-21

Page 318

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Using DOS Commands and Applications (continued) Problem

Solution

The reader does not boot after you modified the CONFIG.SYS file.

Boot the reader and press when you see this message, “Loading MS-DOS 5.0 ROM Version.” The DOS setup screen appears. Press to make the reader reboot without executing the startup files.

2

B

Correct the error in CONFIG.SYS. Use Auto-Loader, BFT, or MkImage and PutImage to load the new CONFIG.SYS onto the reader.

1

B

Boot the reader. When you see the DOS message, press . When the DOS setup screen appears, press . The reader should boot with the corrected CONFIG.SYS file. You see this message when you use Interlnk/Intersrv to copy files between the reader and the host computer: Not ready writing drive X Abort, Fail, Retry

R

Press to Retry and continue copying the files. You may have a problem copying files if you use the DOS version (utilities from your PC) of INTERLNK.EXE and INTERSVR.EXE on the JANUS reader. Intermec modified the INTERLNK.EXE and INTERSVR.EXE utilities to work with the JANUS reader. The Intermec version of these utilities is provided on the reader’s Drive D and on the MS-DOS Programs Companion Disk 2. Use the INTERLNK.EXE and INTERSVR.EXE utilities provided with your reader to transfer and copy files. If you files were not copied correctly, try the procedure again using the INTERLNK.EXE and INTERSVR.EXE utilities provided with your reader.

10-22

Page 319

NF

BC Troubleshooting

10

Using MkImage and PutImage This table lists problems that may occur when you use MkImage to create a new image file for drive C or use PutImage to load the image file onto drive C. Problem

Solution Verify that you have the correct path and filename in the MkImage or PutImage command and then try again.

Error, number incorrect of parameters

2020U.201

Error, path

Verify the path you entered with the MkImage command and then try again. You must enter the full path for the source directory, beginning with the root directory of the source drive.

invalid

2020U.216

If you do not supply a full path, the current working directory is used, which results in a corrupt image file that will not function properly on the reader. Verify the directory where the files are located for the MkImage command and then try again.

Error, no files found in directory

2020U.035

Error, files in selected dir require too much space to create the disk image

The total combined size of the files in the source directory exceed the capacity of the reader’s drive C, which is 512 bytes. Reduce the size or number of files and then try again.

2020U.037

The number of individual files exceed the number of files allowed. You can have a maximum of 127 files in the directory for drive C. Reduce the number of files and then try again.

Error, too many files exist in directory

2020U.041

Error, could not open output file

The MkImage command syntax for the filename is invalid, or there is not enough space on the disk. Verify the command and filename and then try again. If that does not solve the problem, free some disk space.

2020U.202

10-23

Page 320

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Using MkImage and PutImage (continued) Problem

Solution Free some conventional memory and then try to run MkImage again. For help, see “Making More Memory Available on the Reader” in Chapter 3.

Error, not enough free conventional memory to create disk image

2020U.043

Error, not enough free disk memory to create output file

There is not enough memory on your disk to create the MkImage output file. Remove one or more files and free some disk space.

2020U.045

Verify that the image file exists and you have the correct path and filename in the PutImage command and then try again. Error, could not open image file

2020U.047

Verify that the image file exists and you have the correct path and filename in the PutImage command and then try again. Error, image file not found

2020U.049

Error, invalid image file, recreate using the MkImage command.

The image was created by a method other than MkImage, or you entered the wrong filename in the PutImage command. Create the image file with MkImage, and then try running PutImage again.

2020U.051

Error, not enough free conventional memory to run this program. 2020U.053

10-24

Free some conventional memory and try to run PutImage again. For help, see “Making More Memory Available on the Reader” in Chapter 3.