Page 301

NF

BC Troubleshooting

10

Powering Up or Booting the Reader (continued) Problem

Solution

When you turn on or cold boot the reader, the Boot Loader menu appears. The menu may not list all the Boot Loader commands, and the screen may include a status message. For example:

The bootstrap checks the system flash when doing a resume or cold boot. If the system flash is corrupt or there are bad checksum error messages, it brings up the Boot Loader menu. Read the status messages at the bottom of the menu:

BOOT

LOADER

Dump Load Storage Off Bad BIOS Checksum Please Load BIOS

2020U.191

• If you see “Bad BIOS Checksum” or a message that indicates the system flash is corrupt, save the contents of conventional memory and reload the system flash. For help, see “Dumping the Reader’s 640K Conventional Memory” and “Loading Flash Memory” in Chapter 9.

ee

• If you see “Bad Saved State,” the reader may have been in Storage mode. Press to reboot. If you are prompted to exit Storage mode, press again.

q e

You may also see the “Bad Saved State” message if you press to suspend the reader while it is booting. Press to reboot the reader. You may be able to save the contents of the physical RAM drive. For help, see “Saving the Contents of the RAM Drive” later in this chapter.

Caution When the reader performs a cold boot, all files on the physical RAM drive are destroyed. Conseil Lorsque le lecteur effectue un amorçage à froid, tous les fichiers présents sur le lecteur de la mémoire RAM physique sont supprimés. When the reader finishes booting, an icon remains on at the top of its display.

Contact your Intermec service representative. When the reader boots, the CPU starts all power cycles and turns all icons (except for Battery) on and off. The icons turn off very quickly as the reader passes a series of bootstrap code checks. Any icon that remains on indicates where the bootstrap code failed.

10-5

Page 302

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Operating the Reader This table lists problems that may occur when you operate the reader. For example, if you have problems entering or scanning data, some solutions are listed in the table. Problem

Solution

You cannot remember the password to access the Boot Loader menu.

Contact your Intermec service representative.

When you try to start IC.EXE, the reader displays an error message indicating that there is not enough memory available to run the Configuration Manager.

If the Configuration Manager TSR is unloaded when you start IC.EXE, the reader automatically loads the TSR for you. If there is not enough conventional memory available for the TSR, the reader displays an error message. Make sure at least 50K of memory is available. For help, see “Making More Memory Available on the Reader” in Chapter 3.

You scan a valid configuration command, but the reader beeps and displays an error message such as “Bad command or filename.”

Make sure the Configuration Manager TSR is loaded in memory. You can scan configuration commands only if the TSR is loaded. For help, see “Unloading and Loading Configuration Manager TSR” in Chapter 3.

You want to return to the default configuration.

Follow the instructions in “Restoring the Reader’s Default Configuration” in Chapter 5.

You see one of these error messages when you try to run an application:

If you developed an application that refers to a specific drive letter, make sure the drive letter is correct. If the drive is not correct, you can change the application to refer to the new drive letters or to use a relative path instead of an absolute path. You can also use the DOS SUBSTITUTE command, as described in “If Your Applications Refer to Specific Drive Letters” later in this chapter.

• “File not found”

• “Not ready reading drive X. Abort, Retry, Fail?”

Note: Some drive letters on the JANUS reader were changed with software version 2.10. While writing to a PC card in the PC card drive, you turn off the reader, pull out the card, modify the card, insert it back in the reader, and turn on the reader.

The reader will continue to write to the PC card when you turn it back on. The file you were writing to is out of sequence. Your PC card may be corrupted. If you cannot access the data on the card, you may need to format it.

While writing to a PC card in the PC card drive, you turn off the reader, pull out the card, and turn on the reader without a card.

You have interrupted the write process. You will lose the data you were writing to the PC card.

10-6

Page 303

NF

BC Troubleshooting

10

Operating the Reader (continued) Problem

Solution

You cannot tell if the numeric keypad is enabled or disabled.

You can check if the numeric keypad is enabled or disabled by pressing and a number. For example, press and see what appears on the reader’s display:

You scan a reader command, such as Backlight On, and nothing happens.

u u5

Display

Indicates This State

%

The number pad is disabled.

5

The number pad is enabled with Num Lock on.

blank

The number pad is enabled with Num Lock off.

The reader commands are disabled. Scan the Enable Override command shown below to temporarily enable all of the reader commands. You can also enable or disable reader commands with IC.EXE. For help, see “Command Processing” in Chapter 12. Enable Override

*$+DC3* *$+DC3*

When you run an application, the reader scrolls at line 25 and uses Automatic Viewport Movement mode regardless of the way you configured these parameters.

If you want the reader to scroll at another line or use Manual Viewport Movement mode while running an application, you must explicitly set those parameters in the application. You can use, for example, PSK functions.

The reader decodes a bar code label in a symbology other than the label’s actual symbology.

Try scanning the bar code label again. Make sure you scan the entire label.

You cannot scan bar code labels.

See “Scanning Bar Code Labels” later in this chapter.

You see this message, “Configuration Manager TSR is not loaded.”

You typed cfgmgr -d to unload the Configuration Manager TSR from memory, but it has already been unloaded. No action is required.

You see this message, “Configuration Manager TSR already loaded.”

You typed cfgmgr to load the Configuration Manager TSR into memory, but it has already been loaded. No action is required.

To ensure that the reader can operate quickly and efficiently, you should enable only the bar code symbologies that you are going to scan. If you enable multiple symbologies, the reader may on rare occasions decode a bar code according to the wrong symbology and produce erroneous results.

10-7

Page 304

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Operating the Reader (continued) Problem

Solution

The user application is not receiving the bar code input properly.

Reader Services may have been unloaded. The reader cannot decode bar code labels unless Reader Services are loaded. Verify that the IF EXIST D:\RDG.BAT CALL D:\RDG.BAT command is in AUTOEXEC.BAT, and then warm boot the reader to reload Reader Services. If you cannot load Reader Services, you may have assigned too much conventional memory to the physical RAM drives. For help, see “Deciding How Much Memory to Use for RAM Drives” in Chapter 3.

Caution Do not press any keys while the reader is performing a warm boot or you may lose data. Conseil N'appuyez pas sur des touches pendant que le lecteur se réamorce, sinon vous pouvez perdre des données. The Battery icon appears at the top of the reader display.

The reader displays the Battery icon when the NiCad battery pack has approximately 15 to 45 minutes of power left. If you are using a J2020, replace the battery pack soon. If you are using a JR2020, you should immediately replace or recharge the battery pack because you will soon lose RF communications.

Caution When the Battery icon appears, save your data and replace the battery pack as soon as possible. Conseil Quand l’icône de la pile apparaît, enregistrez vos données et remplacez le jeu de piles aussitôt que possible, sinon vous pourriez perdre des données.

10-8

Page 305

NF

BC Troubleshooting

10

Operating the Reader (continued) Problem

Solution

You see all these symptoms:

The NiCad battery pack charge is critically low.

• The Battery icon remains on.

Save your data. Replace the battery pack with a spare charged battery pack, charge the battery pack, or attach an external power supply.

• The reader chirps every 5 seconds for 1 minute and then turns off. • The reader sounds a double-beep when you enter or scan data, and sounds a double-click when you press any key.

The laser scanner and RF communications are turned off 15 seconds after the first chirp.

You see all these symptoms:

The lithium backup battery is critically low.

• The Battery icon is not displayed.

Keep a charged NiCad battery pack installed in the reader. You can also attach an external power supply. Save all your data and back up all the files that are on drive E.

• The reader chirps every 15 seconds for 1 minute and then turns off. • The reader sounds a double-beep when you enter or scan data, and sounds a double-click when you press any key. • The Backup Battery screen appears each time you turn the reader on. The reader appears to be locked up and you cannot enter data.

Contact your Intermec service representative to replace the lithium backup battery.

q q

Press to turn off the reader. If the reader will not turn off, see the next problem in this table for help. Press to turn on the reader. If the reader displays the Boot Loader menu with the message “Bad Saved State,” press to cold boot the reader. You may be able to save the contents of the physical RAM drive. For help, see “Saving the Contents of the RAM Drive” later in this chapter.

e

Caution When the reader performs a cold boot, all files on the physical RAM drive are destroyed. Conseil Lorsque le lecteur effectue un amorçage à froid, tous les fichiers présents sur le lecteur de la mémoire RAM physique sont supprimés.

10-9

Page 306

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Operating the Reader (continued) Problem

Solution

The reader appears to be locked up or is beeping every 10 seconds. When you press to turn off the reader, it does not turn off.

Press - to turn off the reader. It may take a few seconds before the reader turns off. When you press to turn on the reader, it displays the Boot Loader menu.

q q 5j q

Read the status messages at the bottom of the menu. If the messages tell you to resume, choose Resume from the Boot Loader menu. If the messages tell you to reboot, choose Reboot from the Boot Loader menu to cold boot the reader. You may be able to save the contents of the physical RAM drive. For help, see “Saving the Contents of the RAM Drive” later in this chapter.

Caution When the reader performs a cold boot, all files on the physical RAM drive are destroyed. Conseil Lorsque le lecteur effectue un amorçage à froid, tous les fichiers présents sur le lecteur de la mémoire RAM physique sont supprimés. All the files on drive E have been erased.

The contents of drive E, the physical RAM drive, are destroyed when you perform these tasks: • You cold boot the reader.

• You load the reader’s flash memory. • You put the reader in Storage mode. • You execute CONFIG.SYS after changing the command that creates the RAM drive.

q

• You turn off the reader (by pressing or removing the NiCad battery pack) while the reader is performing a warm boot. • You removed and replaced a discharged NiCad battery pack, instead of inserting a fully charged battery pack. • You run an application on the reader that masks the non-maskable interrupt (NMI). While this is acceptable on a PC, it is not acceptable on a reader. You must restore or copy your files to the RAM drive E.

10-10

Page 307

NF

BC Troubleshooting

10

Operating the Reader (continued) Problem

Solution

The reader displays the Boot Loader menu.

The reader displays the Boot Loader menu in response to several error conditions: • You turned off the reader (by pressing q or removing the NiCad battery pack) while the reader was performing a warm boot.

• You removed and replaced a discharged NiCad battery pack, instead of inserting a charged battery pack. • You ran an application on the reader that masks the non-maskable interrupt (NMI). While this is acceptable on a PC, it is not acceptable on a reader. • There may be another problem with the reader. Read the status messages at the bottom of the menu. If the messages tell you to resume, choose Resume from the Boot Loader menu. If the messages tell you to reboot, choose Reboot from the Boot Loader menu to cold boot the reader. You may be able to save the contents of the physical RAM drive. For help, see “Saving the Contents of the RAM Drive” later in this chapter.

Caution When the reader performs a cold boot, all files on the physical RAM drive are destroyed. Conseil Lorsque le lecteur effectue un amorçage à froid, tous les fichiers présents sur le lecteur de la mémoire RAM physique sont supprimés. You need to cold boot the reader and you want to save the contents of drive E, the physical RAM drive.

For help, see “Saving the Contents of the RAM Drive” later in this chapter.

10-11

Page 308

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Saving the Contents of the RAM Drive When you cold boot the reader, the contents of drive E, the physical RAM drive, are normally destroyed. You may be able to save the contents of the RAM drive by using this procedure. To save the contents of the physical RAM drive 1. From the Boot Loader menu, choose Reboot. Caution When the reader performs a cold boot, all files on the physical RAM drive are destroyed. Conseil Lorsque le lecteur effectue un amorçage à froid, tous les fichiers présents sur le lecteur de la mémoire RAM physique sont supprimés. 2. Press d as soon as you see the RAM memory test message:

BIOS Ver x.xxx Copyright 1992-199x All Rights Reserved 00120K RAM Passed

Note: You must press d before the memory counter reaches 00640K RAM Passed.

3. The reader continues booting. At the DOS prompt, enter this command: dir e:

If the contents of drive E are displayed, you can continue using the reader. If the contents of drive E are destroyed, you must restore or copy your files to drive E.

10-12

Page 309

NF

BC Troubleshooting

10

Networking or Communicating With the Reader This table lists problems that may occur when the reader is communicating with another device. Note: If you have problems with your RF network, see your JANUS RF documentation. Problem

Solution

Communications problems occur only when you connect the optical link adapter to a reader and no external power source is attached.

The reader may not be in good contact with the optical link adapter. Inspect the spring contacts and contact surfaces on the optical link adapter for signs of corrosion or contamination. If necessary, clean the contacts with a cotton swab and an alcoholbased solvent. Other solvents may damage the plastic housing.

The communications application cannot communicate.

Verify that the reader and the other device are using the same communications protocol and parameter settings. If they do not match, change them and restart the communications application. Make sure the reader’s optical port, communications dock, and optical link adapter are clear of foreign material. Wipe the optical port window with a damp cloth to remove any material that may be blocking the light from the LEDs. You may need to reset the UART FIFO control register. For help, see “Specifying a Value for the FIFO Control Register” in Chapter 6.

You attempt to load PHIMEC, and the reader displays the message, “Comm port not available.”

The PHIMEC protocol handler has not been loaded into memory. You attempted to load PHIMEC to a COM port other than COM1. Load the protocol handler again. For help, see “Loading and Unloading a Protocol Handler” in Chapter 6.

When you use the Multi-Drop protocol and 19.2 bps baud rate, the communications application times out or waits indefinitely on a receive request, and the 9154 Multi-Drop Line Controller’s fault light turns on.

The packets are too large (over 30 bytes) for the JANUS reader to handle at the 19.2 bps baud rate. Lower the baud rate to 9600 bps.

You experience problems with the reader display when you run terminal emulation (TE) on the reader. For example, the prompt disappears after you run a program.

When you run TE on the reader, the CONFIG.SYS file loads ANSI.SYS. ANSI.SYS interacts with IM_DISP.EXE, causing unpredictable effects on the reader’s display. Remark out IM_DISP.EXE in the AUTOEXEC.BAT file while you use TE. For help editing AUTOEXEC.BAT, see “Learning How to Change the Contents of Drive C” in Chapter 3.

10-13

Page 310

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Networking the Reader (continued) Problem

Solution

The communications application appears to stop executing or locks up.

The reader may have lost its connection with the communications dock, optical link adapter, or other device. Verify that the reader is still connected to the other device. Make sure all the cables are firmly connected to each device. If you are using a communications dock, make sure the reader is placed correctly in the reader slot. If the reader was disconnected, restart the communications application. If it is still locked up, warm boot the reader. Check the communications protocol configuration and make sure you have set timeout values.

Caution Do not press any keys while the reader is performing a warm boot or you may lose data. Conseil N'appuyez pas sur des touches pendant que le lecteur se réamorce, sinon vous pouvez perdre des données. You may experience problems with your RF network, such as: • The RF option is not listed in the Com menu of IC.EXE. • The RF protocol handler (RFPH) did not load correctly. • The Connect icon turns off.

10-14

If you have any problems with your RF network, see your JANUS RF documentation.