The text of a manual · part 30 of 57
JANUS 2020 Hand-Held Computer User's Manual, pages 291 to 300
Pages 291 to 300 of 570
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2020 and Intermec JR2020
Page 291
NF
BC Booting and Resetting the Reader
9
To exit Storage mode 1. Install the reader’s NiCad battery pack. For help, see “Installing the Battery Pack” in Chapter 2. 2. Press q to turn on the reader.
3. Type the password if the reader prompts you to do so. The Boot Loader menu appears. 4. From the Boot Loader menu, select Reboot. The reader begins rebooting, displays the BACKUP BATTERY screen, and asks if you want to exit Storage mode.
BACKUP
BATTERY
Backup Battery Tests Good Storage
Mode is
On
Please Press Enter to Continue Esc to Go Off
2020U.039 e
5. Press to exit Storage mode, continue booting the reader, and return to the DOS prompt.
d
Note: If you press the reader remains in Storage mode. Immediately remove the battery pack, as described in Chapter 2.
9-13
Page 292
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Dumping the Reader’s 640K Conventional Memory If you cannot resume the reader, you may need to cold boot the reader or load flash memory to resolve the error condition. However, all data in conventional memory will be lost when you perform either of these tasks. You can save the contents of the reader’s 640K conventional memory by dumping it to a host computer. The host computer must be running a communications program that can receive and store the data from the reader’s memory. To dump the reader’s 640K conventional memory to a host computer 1. Connect the reader to a host computer using the optical link adapter or the communications dock. The reader transmits and receives data at 4800 baud, no parity, 8 data bits, and 1 stop bit. 2. Run a communications program, such as Crosstalk, that saves data on the host computer. This program is not provided with the reader.
q n 2g 2 q
3. Display the Boot Loader menu: a. Press b. Press c. Press d. Press to turn off the reader. -
- .
.
to turn on the reader.
e. Type the password if the reader prompts you to do so. If you fail to enter the correct password after three attempts, the reader resumes normal operation.
e
4. The Boot Loader menu appears. Press press .
Boot j until you select Dump, and then
Loader
Reboot Password Dump Load Resume Storage Off
2020U.091
The reader dumps data from low memory (640K and below) through COM1 to the host computer. The data is transmitted in Intel hexadecimal object file format.
9-14
Page 293
NF
BC Booting and Resetting the Reader
9
5. A record counter on the reader display counts the data as it is transmitted to the host computer. The record counter stops updating when the reader is finished downloading the data.
e
6. Choose your next step. You can cold boot the reader by choosing the Reboot command and pressing . Then you can use the reader. If you dumped the 640K because the Boot Loader menu displayed the “Bad BIOS Checksum” error message or because the flash memory was corrupted, you must load the flash memory now. For help, see the next section, “Loading Flash Memory.”
9-15
Page 294
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Loading Flash Memory You can download all of the reader’s flash memory from a host computer if the Boot Loader menu displays the “Bad BIOS Checksum” error, if flash memory is corrupted, or if you need to upgrade the reader’s software. Loading flash memory replaces: • drive C, the 512K ROM drive resident in flash memory.
• drive D, the 2MB ROM drive.
• the 256K flash system image.
Also, because you will reboot the reader near the end of this process, the contents of the physical RAM drive (drive E) will be destroyed. Caution When you load the reader’s flash memory, all data in conventional memory will be lost. Conseil Lorsque vous chargez la mémoire flash du lecteur, vous perdez toutes les données de la mémoire conventionnelle. If you are upgrading the reader’s software, follow the instructions in the JANUS Software Upgrade Instruction Sheet. To load the reader’s flash memory 1. Decide if you want to save the contents of conventional memory. If so, you must perform the steps in the previous section, “Dumping the Reader’s 640K Conventional Memory,” now. 2. Decide if you want to save any files on drives C and E, such as customized startup files, applications, or configuration files. If so, you must copy the files to a PC card, another reader, or a host computer now. For help, see “Running Interlnk to Transfer Files” in Chapter 6. 3. Connect the reader to a host computer using an optical link adapter or the communications dock. Use a null modem RS-232 cable to attach the accessory to the host computer. This cable is the same one you would use for Interlnk. 4. Connect a power supply to the communications dock or optical link adapter. 5. Press
9-16 q to turn on the reader.
Page 295
NF
BC Booting and Resetting the Reader
9 q n 2g 2 q
6. If the Boot Loader menu does not appear, follow these steps to display it: a. Press b. Press c. Press d. Press to turn off the reader. -
- .
.
to turn on the reader.
e. Type the password if the reader prompts you to do so. If you fail to enter the correct password after three attempts, the reader resumes normal operation. 7. At the Boot Loader menu, press
Boot j until you select Load.
Loader
Reboot Password Dump Load Resume Storage Off
2020U.093
8. Press e to execute the Load command.
9. Insert the Boot Utilities companion disk 1 into a disk drive on the host computer. 10. On your host computer, type the Upgrade command. Follow this syntax: source:\upgrade /com_port source: destination:
where: source is the disk drive on the host computer where you inserted companion disk 1.
com_port is the number of the serial COM port on the host computer that the reader is connected to.
destination is the drive on the host computer that you are using as a temporary work space while installing the loader and flash files. The drive must have at least 3.5MB of free disk space.
For example, if the disk is inserted in the host’s drive A, the host’s drive C is your temporary work space, and the reader is connected to the host’s COM1, type this command on the host computer and press :
e a:\upgrade /com1 a: c:
9-17
Page 296
JANUS 2020 Hand-Held Computer User’s Manual NF BC
The upgrade program begins executing. It takes a little over 10 minutes to update or upgrade all of the reader’s flash memory. 11. Press any key to skip the online instructions about checking connections to the reader and putting the reader in Load mode. You already performed those tasks. The online instructions are provided for users who do not have these printed instructions. 12. When the upgrade program finishes, it indicates the upgrade was successful. Press any key to return to the DOS prompt on your host computer. The files are deleted from the temporary work space on the host computer. 13. After you return to the DOS prompt on your PC, the reader displays the message, “System Has Reset, Please Reboot.” Choose Reboot from the Boot Loader menu and press to cold boot the reader.
e
Caution When the reader performs a cold boot, all files on the physical RAM drive are destroyed. Conseil Lorsque le lecteur effectue un amorçage à froid, tous les fichiers présents sur le lecteur de la mémoire RAM physique sont supprimés. 14. Reload any files or programs you had on drives C and E. For help, see “Learning How to Change the Contents of Drive C” in Chapter 3. Note: If you are upgrading to a new version of software, do not reload the startup files and drivers you used for the previous release. 15. If the reader operates in a language other than English, you must configure the reader to use that language. Use Auto-Loader as described in Chapter 8, “Preparing the Reader for International Use.”
9-18
Page 297
NF
BC
10 Troubleshooting
Page 298
NF
BC
Page 299
NF
BC Troubleshooting
10
This chapter describes how to solve problems that may arise when you operate the reader.
How to Use This Chapter If you have a problem operating the reader, read this chapter for a solution. For easy reference, problems are grouped into these topics: •
Powering Up or Booting the Reader
•
Operating the Reader
•
Saving the Contents of the RAM Drive
•
Networking or Communicating With the Reader
•
Running IRL Programs
•
Using PC Cards
•
Using DOS Commands and Applications
•
Using MkImage and PutImage
•
Scanning Bar Code Labels
•
Problems With the NiCad Battery Pack
•
If Your Applications Refer to Specific Drive Letters
•
Upgrading Flash Cards for JANUS 2.1 Software
Caution There are no user-serviceable parts inside the reader. Opening the unit will void the warranty and may cause damage to the internal components. Conseil La reader ne contient pas de pièces révisibles par l’utilisateur. Le fait d’ouvrir l’unité annule la garantie et peut endommager les pièces internes. If you send the reader in for service, it is your responsibility to save the reader applications, data, and configuration. Intermec is responsible only for ensuring that the keypad and other hardware features match when replacing your unit.
10-3
Page 300
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Powering Up or Booting the Reader This table lists problems that may occur when you turn on, turn off, or boot the reader. Problem q
When you press to turn on the reader, nothing happens or the reader immediately turns itself off.
Solution Make sure the NiCad battery pack is installed correctly. Push firmly on the bottom of the battery pack to lock it into the reader handle. The NiCad battery pack may be discharged. Replace the battery pack with a spare charged battery pack, or charge the battery pack and try again.
During a warm boot, the reader cannot finish booting and displays an error message.
cau f
If you press a key (especially or ) while the reader is booting, you may see the message, “XX Keyboard Error, Press F1 or F2,” where XX is an error code such as FA. Press to exit the error screen and the reader continues booting.
m
Caution Do not press any keys while the reader is performing a warm boot or you may lose data. Conseil N'appuyez pas sur des touches pendant que le lecteur se réamorce, sinon vous pouvez perdre des données. When you turn on the reader, the power management software displays an error message.
An error occurred and the reader cannot resume operating. You can turn the reader off without losing data, provided there is sufficient battery power. The next time you turn on the reader, the error sequence repeats and the Boot Loader menu appears. If you reboot the reader, you will lose all the data in the reader’s 640K conventional memory. You can save the contents of conventional memory and reload the system flash. For help, see “Dumping the Reader’s 640K Conventional Memory” and “Loading Flash Memory” in Chapter 9.
10-4