BC Troubleshooting

10

Using MkImage and PutImage (continued) Problem

Solution Unload the EMM manager (EMM386.EXE) and try running PutImage again.

Error, EMM Manager is installed, reboot without EMM Support before using PutImage 2020U.055

Three things could have happened: Error, unable to turn on flash programming voltage

2020U.057

• You do not have an external power supply attached to the reader. You must provide an external power supply for the reader before you execute PutImage. Connect a communications dock or optical link adapter to the reader, and then connect a power supply to the dock or adapter. • There is a hardware problem. • Some other subsystem (such as a PC card) is presently using the 12V. Wait, and try using PutImage again later. You must provide an external power supply for the reader before you execute PutImage. Connect a communications dock or optical link adapter to the reader, and then connect a power supply to the dock or adapter.

Error, cannot program flash due to low battery

2020U.061

When you start PutImage, one of these messages appears: • Critical error, invalid checksums have occurred. • Critical error, invalid image file.

A critical error occurred. You cannot reboot the reader, but you can save the data held in conventional memory and reload the reader’s flash memory. For help, see “Dumping the Reader’s 640K Conventional Memory” and “Loading Flash Memory” in Chapter 9.

• Critical error, a write fault has occurred. • Critical error, erase was bad.

10-25

Page 322

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Scanning Bar Code Labels If you cannot scan bar codes with the reader, locate your problem in the list and follow the instructions: You cannot see a red light when aiming at a wall. You may be too far from the wall. Move within 2 feet of the wall and test the scanner again. Or test the scanner by pointing it at the floor. The scanner will not register the bar code label you are trying to scan. Make sure you aim the beam so it crosses the entire label in one pass. If your scanner still will not register the scan, it may mean that you did not enable the symbology of the bar code. For help, see “Choosing the Symbologies the Reader Will Decode” in Chapter 5. If you still have trouble with the scanner, perform these checks: •

Inspect the print quality of the bar code. Try scanning a bar code label that you know scans. Compare the two bar code labels. You may need to replace the label that cannot be scanned.

•

Make sure the reader is turned on. Press

•

You try to scan a bar code label and the scanner turns off or will not turn on. If the reader is chirping every 5 seconds and the Battery icon is displayed, you have a low NiCad battery pack. You must turn off the reader and replace the battery pack.

•

You scan a bar code label that contains a valid configuration command, but the reader beeps and displays an error message such as, “Bad command or filename.” Make sure the Configuration Manager TSR is loaded into memory. If it is not loaded, you cannot scan configuration commands. Type cfgmgr and press to load Configuration Manager and rescan the bar code label.

q to turn the reader on.

e

10-26

•

You scan a bar code label to enter data at the DOS prompt, but the reader beeps and displays an error message such as, “Bad command or filename.” Make sure the application that is expecting the data is running. If necessary, start the application and scan the bar code again.

•

Clean the scanning window of the laser scanner with a solution of ammonia and water. Wipe dry. Do not allow abrasive material to touch the window.

•

Use IC.EXE to verify that the reader is configured to read the bar code symbology you are scanning.

Page 323

NF

•

BC Troubleshooting

10

Scan the bar code again, but vary the scanning angle and distance.

20 ° Angle 2020U.017

•

Verify that the command IF EXIST D:\RDG.BAT CALL D:\RDG.BAT is executed from the AUTOEXEC.BAT file. If the command is not executed, the reader cannot decode bar code labels.

•

The SCANNER.INI file contains configuration information for each type of scanner device. The SCANNER.INI file must remain on drive D.

10-27

Page 324

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Problems With the NiCad Battery Pack Follow these guidelines to avoid problems with the NiCad battery pack and the reader: •

Always turn the reader off BEFORE you remove the NiCad battery pack.

•

Periodically clean the NiCad battery pack contacts to maintain good contact with the reader. Use a cotton swab and some rubbing alcohol to clean the gold contacts on the sides of the battery pack.

Battery contact (3) 2020U.298

•

If the battery pack appears to lose its charge capacity, discharge the battery pack using the communications dock or battery charger before charging it. It is not necessary to discharge the battery pack every time you charge it, only when you notice problems. If the battery pack still will not hold a charge, try using a new battery pack. For help, see the accessory quick reference guides.

•

If the JL2010 optical link adapter fails to charge the battery pack when connected to a power supply, inspect the spring contacts and contact surfaces on the optical link adapter for signs of corrosion or contamination. If necessary, clean the battery charging contacts with a cotton swab and some rubbing alcohol. Other solvents may damage the plastic housing on the optical link adapter.

2020U.203

Battery charging contact (2)

10-28

Page 325

NF

BC Troubleshooting

10

Problems With the NiCad Battery Pack (continued) The next table lists problems you may have with the NiCad battery pack while operating the reader. Problem q

Solution

When you press to turn on the reader, nothing happens or the reader immediately turns itself off.

Make sure the NiCad battery pack is installed correctly. Push firmly on the bottom of the pack to lock it into the handle.

The Battery icon appears at the top of the reader display.

The reader displays the Battery icon when the NiCad battery pack has approximately 15 to 45 minutes of power left. If you are using a J2020, replace the battery pack soon.

The NiCad battery pack may be discharged. Replace the battery pack with a spare charged battery pack, or charge the battery pack and try again.

If you are using a JR2020, you should immediately replace or recharge the battery pack because you will soon lose RF communications.

Caution When the Battery icon appears, save your data and replace the battery pack as soon as possible. Conseil Quand l’icône de la pile apparaît, enregistrez vos données et remplacez le jeu de piles aussitôt que possible, sinon vous pourriez perdre des données. You see all these symptoms:

The NiCad battery pack charge is critically low.

• The Battery icon remains on.

Save your data. Replace the battery pack with a spare charged battery pack, charge the battery pack, or attach an external power supply.

• The reader chirps every 5 seconds for 1 minute and then turns off. • The reader sounds a double-beep when you enter or scan data, and sounds a double-click when you press any key.

The laser scanner and RF communications are turned off 15 seconds after the first chirp.

10-29

Page 326

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Problems With the NiCad Battery Pack (continued) Problem

Solution

You see all these symptoms:

The lithium backup battery is critically low.

• The Battery icon is not displayed.

Keep a charged NiCad battery pack installed in the reader. You can also attach an external power supply. Save all your data and back up all the files that are on drive E.

• The reader chirps every 15 seconds for 1 minute and then turns off. • The reader sounds a double-beep when you enter or scan data, and sounds a double-click when you press any key. • The Backup Battery screen appears each time you turn the reader on.

10-30

Contact your Intermec service representative to replace the lithium backup battery.

Page 327

NF

BC Troubleshooting

10

If Your Applications Refer to Specific Drive Letters In JANUS software version 2.10, some drive letters were changed. If you are using an application that refers to a specific drive letter on a JANUS reader with software version 2.10 or later, you may see messages like “File Not Found” or “Not ready reading drive X. Abort, Retry, Fail?” You may need to change your applications if you have developed them for a JANUS reader that has an earlier software version. The drive letter change in software version 2.10 will only affect your applications if the application is coded to use specific drive letters (uses an absolute path). Note: If your applications do not use specific drive letters, you can use the applications on a reader with software version 2.10 without making changes. If you have JANUS readers with software version 1.31 or earlier, you may need to change your applications if you: •

Use readers with different software versions and one of the versions is 2.10 or later. For example, a J2020 reader with 2.10 software and a J2020 reader with 1.30A software.

•

Upgrade all your JANUS readers to software version 2.1 or later.

If your application uses specific drive letters, you have these options: •

Change your application to query the reader for its drive letters (use a logical or relative path). You can use the revised application on any reader with any software version.

•

You can use the DOS Substitute command on readers with software version 2.10 or later to change the drive letter assignments to match readers with earlier software versions. For help, see “To use the Substitute command” on the next page.

•

If you are upgrading all of your readers to software version 2.1 or later, you can continue to use specific drive letters. Change your application to use the new drive letters for the new software version, and use the revised application on any reader with software version 2.10 or later.

•

If you want to continue to use specific drive letters and you have a mix of software versions, you need to create two versions of the application. One version is coded to use the drive letters for software versions 1.31 or earlier. The second version is coded to use the drive letters for software version 2.10 or later.

You can use the DOS Substitute command to substitute a drive letter for another drive letter on the reader. With the Substitute command, you can change the drive letters on a reader with software version 2.10 or later to match the drive letters on a reader with an earlier software version.

10-31

Page 328

JANUS 2020 Hand-Held Computer User’s Manual NF BC

When using the Substitute command on the reader, you can: • add the Substitute command to the AUTOEXEC.BAT file so that the drive letter assignments are changed each time the reader is booted.

• execute the Substitute command at the DOS prompt to temporarily change the drive letter assignments.

• execute the Substitute command in a batch file.

These commands do not work on drives used in the Substitute command: CHKDSK

LABEL

DISKCOMP

MIRROR

DISKCOPY

RECOVER

FORMAT

SYS

For a complete description of the Substitute command, see any DOS 5.0 user’s manual or guide. To use the Substitute command 1. Insert a PC card in the PC card drive. For example, insert a PC card in the JANUS 2020 PC card drive. Caution You must insert a PC card in each PC card drive or you will get a critical error message when the reader executes the Substitute command. Conseil Vous devez insérer une carte PC dans chaque lecteur PC. Sinon, un message d’erreur critique s’affiche lorsque le lecteur exécute la commande Substitute. Note: DOS requires that a drive is present when you execute the Substitute command. 2. Type the Substitute command and press e

.

subst drive: substitute_drive:

where substitute_drive is the letter you are assigning to the drive. Include a colon after each drive letter in the command. For example, on a J2020 with software version 2.1, use this command to substitute drive G with drive E: subst g: e:

10-32

Page 329

NF

BC Troubleshooting

10

To remove the substitution •

Use the /d switch to delete a virtual drive. For example: subst g: /d

Upgrading Flash Cards for JANUS 2.1 Software A flash PC card must be formatted to match the version of the JANUS software installed on your reader. Flash cards that you use in readers with older versions of JANUS software will not work on readers with JANUS 2.1 software or later, because the new software supports the PCMCIA Standard 2.1 and the old software does not. If you have a mix of readers in your work environment, some with new software and others with older software, you cannot interchange flash cards between readers with different software versions. You should format some cards for the new JANUS 2.1 software, and leave other cards formatted for the older software. You may find it helpful to label the cards and readers with their software version. To format a flash card for the new JANUS 2.1 software 1. If you want to save any files on the flash card, you must copy them before you format the card. Insert the card into a reader with an older version of the software and copy the files to a PC or another reader. 2. Insert the card into a reader with the new JANUS 2.1 software and use the MCFORMAT.EXE utility to format the card. For help, see “Preparing to Use Flash Cards” in Chapter 4. 3. Copy the files from Step 1 back onto the flash card. 4. You are ready to use the reformatted flash card in a reader with the new JANUS 2.1 software.

10-33

Page 330