Page 61
Learning About the INI File
3 display_backlight Description
Specifies the starting state of the JANUS backlight.
Default
0 – Backlight off
Values
0 – Backlight off 1 – Backlight on
Function im_backlight_toggle
Interrupt
INT 79H
Notes
You can change the backlight status by calling these functions: • im_backlight_on
• im_backlight_off
• im_backlight_toggle
3-27
Page 62
JANUS Application Simulator User’s Manual display_char_height Description
Specifies if the characters are displayed at standard height or double height.
Default
0 – Standard height characters
Values
0 – Standard height characters 1 – Double height characters
Function im_get_display_mode
Interrupt
INT 79H
Notes
The value of this INI parameter is returned to the JANUS application in the *char_ht parameter of the im_get_display_mode function call. This parameter does not affect the characters displayed on the development PC. The value held in memory by the Simulator TSR can be modified by the im_set_display_mode function.
3-28
Page 63
Learning About the INI File
3 appl_break_status Description
Specifies if the user entered the application break key sequence to interrupt applications running on the JANUS.
Default
0 – Request for break has not been made
Values
0 – Request for break has not been made 0FFH – Request for break has been made
Function im_appl_break_status
Interrupt
INT 7EH follow_cursor Description
Specifies if the viewport will follow the cursor as it moves around the simulated display.
Default
1 – Follow cursor mode on
Values
0 – Follow cursor mode off 1 – Follow cursor mode on
Function im_get_follow_cursor
Interrupt
INT 7EH
Notes
The value of this INI parameter is returned to the JANUS application in the *follow_cursor parameter of the im_get_follow_cursor function call. The value held in memory by the Simulator TSR can be modified by the im_set_follow_cursor function.
3-29
Page 64
JANUS Application Simulator User’s Manual control_key Description
Specifies if the Control key is enabled or disabled for the simulated im_get_control_key function.
Default
0 – Control key disabled
Values
0 – Control key disabled 0FFH – Control key enabled
Function im_get_control_key
Interrupt
INT 7EH
Notes
The value of this INI parameter is returned to the JANUS application in the *control_key parameter of the im_get_control_key function call. The im_get_control_key function does not enable or disable the control key on the development PC. The value held in memory by the Simulator TSR can be modified by the im_set_control_key function.
3-30
Page 65
Learning About the INI File
3 keyclick Description
Specifies if the JANUS emits a click each time a key is pressed.
Default
0 – Keyclick off
Values
0 – Keyclick off 0FFH – Keyclick on
Function im_get_keyclick
Interrupt
INT 7EH
Notes
The value of this INI parameter is returned to the JANUS application in the *keyclick parameter of the im_get_keyclick function call. The value held in memory by the Simulator TSR can be modified by the im_set_keyclick function.
3-31
Page 66
JANUS Application Simulator User’s Manual numeric_keypad_switching Description
Specifies if the user can switch the numeric keypad from numeric to function keys.
Default
0FFH – Numeric keypad switching permitted
Values
0 – Numeric keypad switching prohibited 0FFH – Numeric keypad switching permitted
Function
None
Interrupt
INT 7EH
Notes
This parameter is provided for interrupt level support only; there is no JANUS PSK library function associated with this parameter. The value held in memory by the Simulator TSR can be modified by the im_number_pad_on and im_number_pad_off functions.
3-32
Page 67
Learning About the INI File
3 numeric_keypad_status Description
Specifies if the numeric keypad is in numeric or function key mode.
Default
0 – Numeric keypad disabled
Values
0 – Numeric keypad disabled 0FFH – Numeric keypad enabled
Function
None
Interrupt
INT 7EH
Notes
This parameter is provided for interrupt level support only; there is no JANUS PSK library function associated with this parameter. The value held in memory by the Simulator TSR can be modified by the im_number_pad_on and im_number_pad_off functions.
3-33
Page 68
JANUS Application Simulator User’s Manual label_symbology Description
Specifies the symbology of the last simulated scanned label.
Default
1 – Code 39
Values
0 – Unknown 1 – Code 39 2 – Code 93 3 – Code 49 4 – Interleaved 2 of 5 (I 2 of 5) 5 – Codabar 6 – UPC/EAN 7 – Code 128 8 – Code 16K 9 – Plessey 10 – Code 11 11 – MSI
Function im_get_label_symbology im_receive_input im_irl_a im_irl_n, im_irl_y
Interrupt
INT 7DH
Notes
The value of this INI parameter is returned to the JANUS application in the *symbology parameter of the function calls that use this INI parameter. When testing a JANUS application, you can simulate the act of scanning a label by pressing the key sequence specified in the sim_wand_key parameter. The label_symbology parameter specifies the symbology for the simulated label.
3-34
Page 69
Learning About the INI File
3 sim_wand_key Description
Specifies the key sequence that causes the JANUS application to accept subsequent keyboard input as if it were wand input.
Default
Ctrl–G
Values
A key combination that includes one or more control keys (Ctrl, Alt, Shift) and a character key (A to Z).
Function
None
Interrupt
None
Notes
The user presses this key sequence and types data that the application accepts as input from a wand. The user presses Enter to indicate the end of the simulated wand input. You can set the sim_wand_key parameter equal to one or more control keys (Ctrl, Alt, Shift) and a character key (A to Z). Here are some sample key sequences: •
Alt–L
•
Alt–Shift–B
•
Ctrl–Shift–C
•
Ctrl–Alt–Shift–W
The INI file displays a slash in the key sequence (Ctrl/G) instead of a hyphen. By convention, this manual uses a hyphen to indicate that you must press multiple keys simultaneously.
3-35
Page 70
JANUS Application Simulator User’s Manual clear_abort_callback_return Description
Specifies the return value upon clearing the abort callback routine.
Default
0500H – Reader Wedge success
Values
See the “Reader Wedge Standard Return Values List” on page 3-40.
Function im_clear_abort_callback
Interrupt
INT 7DH command_return
3-36
Description
Specifies the return value after issuing a configuration command.
Default
0500H – Reader Wedge success
Values
See the “Reader Wedge Standard Return Values List” on page 3-40.
Function im_command
Interrupt
INT 7DH