Page 61

Learning About the INI File

3 display_backlight Description

Specifies the starting state of the JANUS backlight.

Default

0 – Backlight off

Values

0 – Backlight off 1 – Backlight on

Function im_backlight_toggle

Interrupt

INT 79H

Notes

You can change the backlight status by calling these functions: • im_backlight_on

• im_backlight_off

• im_backlight_toggle

3-27

Page 62

JANUS Application Simulator User’s Manual display_char_height Description

Specifies if the characters are displayed at standard height or double height.

Default

0 – Standard height characters

Values

0 – Standard height characters 1 – Double height characters

Function im_get_display_mode

Interrupt

INT 79H

Notes

The value of this INI parameter is returned to the JANUS application in the *char_ht parameter of the im_get_display_mode function call. This parameter does not affect the characters displayed on the development PC. The value held in memory by the Simulator TSR can be modified by the im_set_display_mode function.

3-28

Page 63

Learning About the INI File

3 appl_break_status Description

Specifies if the user entered the application break key sequence to interrupt applications running on the JANUS.

Default

0 – Request for break has not been made

Values

0 – Request for break has not been made 0FFH – Request for break has been made

Function im_appl_break_status

Interrupt

INT 7EH follow_cursor Description

Specifies if the viewport will follow the cursor as it moves around the simulated display.

Default

1 – Follow cursor mode on

Values

0 – Follow cursor mode off 1 – Follow cursor mode on

Function im_get_follow_cursor

Interrupt

INT 7EH

Notes

The value of this INI parameter is returned to the JANUS application in the *follow_cursor parameter of the im_get_follow_cursor function call. The value held in memory by the Simulator TSR can be modified by the im_set_follow_cursor function.

3-29

Page 64

JANUS Application Simulator User’s Manual control_key Description

Specifies if the Control key is enabled or disabled for the simulated im_get_control_key function.

Default

0 – Control key disabled

Values

0 – Control key disabled 0FFH – Control key enabled

Function im_get_control_key

Interrupt

INT 7EH

Notes

The value of this INI parameter is returned to the JANUS application in the *control_key parameter of the im_get_control_key function call. The im_get_control_key function does not enable or disable the control key on the development PC. The value held in memory by the Simulator TSR can be modified by the im_set_control_key function.

3-30

Page 65

Learning About the INI File

3 keyclick Description

Specifies if the JANUS emits a click each time a key is pressed.

Default

0 – Keyclick off

Values

0 – Keyclick off 0FFH – Keyclick on

Function im_get_keyclick

Interrupt

INT 7EH

Notes

The value of this INI parameter is returned to the JANUS application in the *keyclick parameter of the im_get_keyclick function call. The value held in memory by the Simulator TSR can be modified by the im_set_keyclick function.

3-31

Page 66

JANUS Application Simulator User’s Manual numeric_keypad_switching Description

Specifies if the user can switch the numeric keypad from numeric to function keys.

Default

0FFH – Numeric keypad switching permitted

Values

0 – Numeric keypad switching prohibited 0FFH – Numeric keypad switching permitted

Function

None

Interrupt

INT 7EH

Notes

This parameter is provided for interrupt level support only; there is no JANUS PSK library function associated with this parameter. The value held in memory by the Simulator TSR can be modified by the im_number_pad_on and im_number_pad_off functions.

3-32

Page 67

Learning About the INI File

3 numeric_keypad_status Description

Specifies if the numeric keypad is in numeric or function key mode.

Default

0 – Numeric keypad disabled

Values

0 – Numeric keypad disabled 0FFH – Numeric keypad enabled

Function

None

Interrupt

INT 7EH

Notes

This parameter is provided for interrupt level support only; there is no JANUS PSK library function associated with this parameter. The value held in memory by the Simulator TSR can be modified by the im_number_pad_on and im_number_pad_off functions.

3-33

Page 68

JANUS Application Simulator User’s Manual label_symbology Description

Specifies the symbology of the last simulated scanned label.

Default

1 – Code 39

Values

0 – Unknown 1 – Code 39 2 – Code 93 3 – Code 49 4 – Interleaved 2 of 5 (I 2 of 5) 5 – Codabar 6 – UPC/EAN 7 – Code 128 8 – Code 16K 9 – Plessey 10 – Code 11 11 – MSI

Function im_get_label_symbology im_receive_input im_irl_a im_irl_n, im_irl_y

Interrupt

INT 7DH

Notes

The value of this INI parameter is returned to the JANUS application in the *symbology parameter of the function calls that use this INI parameter. When testing a JANUS application, you can simulate the act of scanning a label by pressing the key sequence specified in the sim_wand_key parameter. The label_symbology parameter specifies the symbology for the simulated label.

3-34

Page 69

Learning About the INI File

3 sim_wand_key Description

Specifies the key sequence that causes the JANUS application to accept subsequent keyboard input as if it were wand input.

Default

Ctrl–G

Values

A key combination that includes one or more control keys (Ctrl, Alt, Shift) and a character key (A to Z).

Function

None

Interrupt

None

Notes

The user presses this key sequence and types data that the application accepts as input from a wand. The user presses Enter to indicate the end of the simulated wand input. You can set the sim_wand_key parameter equal to one or more control keys (Ctrl, Alt, Shift) and a character key (A to Z). Here are some sample key sequences: •

Alt–L

•

Alt–Shift–B

•

Ctrl–Shift–C

•

Ctrl–Alt–Shift–W

The INI file displays a slash in the key sequence (Ctrl/G) instead of a hyphen. By convention, this manual uses a hyphen to indicate that you must press multiple keys simultaneously.

3-35

Page 70

JANUS Application Simulator User’s Manual clear_abort_callback_return Description

Specifies the return value upon clearing the abort callback routine.

Default

0500H – Reader Wedge success

Values

See the “Reader Wedge Standard Return Values List” on page 3-40.

Function im_clear_abort_callback

Interrupt

INT 7DH command_return

3-36

Description

Specifies the return value after issuing a configuration command.

Default

0500H – Reader Wedge success

Values

See the “Reader Wedge Standard Return Values List” on page 3-40.

Function im_command

Interrupt

INT 7DH