Page 51

Learning About the INI File

3 power_status_line Description

Specifies the line status of the simulated im_power_status function.

Default

0 – AC line not connected

Values

0 – AC line not connected 1 – AC line connected 255 – Unknown AC line

Function im_power_status

Interrupt

INT 5EH

Notes

The value of this INI parameter is returned to the JANUS application in the *line_status parameter of the im_power_status function call.

3-17

Page 52

JANUS Application Simulator User’s Manual power_status_battery Description

Specifies the simulated condition of the battery.

Default

0 – High battery

Values

0 – High battery 1 – Low 2 – Critical 3 – Charging 255 – Unknown status

Function im_power_status

Interrupt

INT 5EH

Notes

The value of this INI parameter is returned to the JANUS application in the *battery_status parameter of the im_power_status function call.

power_status_backup

3-18

Description

Specifies the simulated condition of the backup battery.

Default

0 – Backup OK

Values

0 – Backup OK 1 – Backup low

Function im_power_status

Interrupt

INT 5EH

Notes

The value of this INI parameter is returned to the JANUS application in the *backup_status parameter of the im_power_status function call.

Page 53

Learning About the INI File

3 power_status_batt_life Description

Specifies the simulated percentage of the battery’s full charge.

Default

100

Values

Numeric value from 0 to 100

Function im_power_status

Interrupt

INT 5EH

Notes

The value of this INI parameter is returned to the JANUS application in the *fuel_gauge parameter of the im_power_status function call.

power_status_return Description

Specifies the return value for the im_power_status function.

Default

0800H – Power management success

Values

0800H – Power management success 8821H – Cannot change state 8822H – Invalid state manager command 8842H – Invalid IPM interface command 8843H – Parameter out of range 8844H – Semaphore maximum value exceeded

Function im_power_status

Interrupt

INT FEH

3-19

Page 54

JANUS Application Simulator User’s Manual display_contrast_level Description

Specifies the contrast level for the JANUS display.

Default

16

Values

Numeric value from 0 to 31

Function im_get_contrast

Interrupt

INT 79H

Notes

The value of this INI parameter is returned to the JANUS application in the *display_contrast_level parameter of the im_get_contrast function call. The value held in memory by the Simulator TSR can be modified by the im_set_contrast function.

3-20

Page 55

Learning About the INI File

3 display_size_mode Description

Specifies the size mode of the JANUS display.

Default

0 – 80 x 25

Values

0 – 80 x 25 1 – 20 x 16 2 – 20 x 8 3 – 10 x 16 4 – 10 x 8

Function im_get_display_mode

Interrupt

INT 79H

Notes

The value of this INI parameter is returned to the JANUS application in the *size_mode parameter of the im_get_display_mode function call. The value held in memory by the Simulator TSR can be modified by the im_set_display_mode function.

3-21

Page 56

JANUS Application Simulator User’s Manual display_video_mode Description

Specifies the video mode of the JANUS display.

Default

3 – Standard video mode 3 (80 x 25)

Values

0 – Standard video mode 0 (40 x 25) 1 – Standard video mode 1 (40 x 25) 2 – Standard video mode 2 (80 x 25) 3 – Standard video mode 3 (80 x 25) 4 – Video mode 4 (graphics) 5 – Video mode 5 (graphics) 6 – Video mode 6 (graphics)

Function im_get_display_mode

Interrupt

INT 79H

Notes

The value of this INI parameter is returned to the JANUS application in the *video_mode parameter of the im_get_display_mode function call. The value held in memory by the Simulator TSR can be modified by the im_set_display_mode function.

3-22

Page 57

Learning About the INI File

3 display_scroll_mode Description

Specifies the line number at which the JANUS display will scroll when the display size is set to 80 x 25.

Default

1 – Scroll at 16

Values

0 – Scroll at line 25 1 – Scroll at 16 2 – Scroll at line 8

Function im_get_display_mode

Interrupt

INT 79H

Notes

The value of this INI parameter is returned to the JANUS application in the *scroll_mode parameter of the im_get_display_mode function call. This parameter is in effect only when the display size is set to 80 x 25. The value held in memory by the Simulator TSR can be modified by the im_set_display_mode function.

3-23

Page 58

JANUS Application Simulator User’s Manual display_viewport_lock Description

Specifies if the JANUS viewport is locked or unlocked.

Default

0 – Locked

Values

0 – Locked 1 – Unlocked

Function im_get_viewport_lock

Interrupt

INT 79H

Notes

If you choose 0 for this parameter, 1 - IM_LOCKED is returned in the *viewport_lock parameter of the im_get_viewport_lock function call. If you choose 1 for this parameter, 0 - IM_UNLOCKED is returned in the *viewport_lock parameter of the im_get_viewport_lock function call. The value held in memory by the Simulator TSR can be modified by the im_set_viewport_lock function.

3-24

Page 59

Learning About the INI File

3 display_x_pos Description

Specifies the horizontal offset for the left side of the simulated viewport.

Default

0

Values

Numeric value from 0 to 60

Function im_viewport_getxy

Interrupt

INT 79H

Notes

The value of this INI parameter is returned to the JANUS application in the *col parameter of the im_viewport_getxy function call. The Simulator TSR does not simulate viewport movement, but it does return the X and Y values to the im_viewport_getxy function: •

The X and Y parameters represent the position where the upper left corner of the JANUS viewport appear on the PC screen.

•

You cannot set X to a value larger than 60. If you could, the viewport would be positioned beyond the left edge of the PC screen.

You can change the X value in memory by calling: • im_viewport_end

• im_viewport_home

• im_viewport_move

• im_viewport_setxy

• im_viewport_to_cursor

• im_viewport_page_up

• im_viewport_page_down

3-25

Page 60

JANUS Application Simulator User’s Manual display_y_pos Description

Specifies the vertical offset for the left side of the simulated viewport.

Default

0

Values

Numeric value from 0 to 9

Function im_viewport_getxy

Interrupt

INT 79H

Notes:

The value of this INI parameter is returned to the JANUS application in the *row parameter of the im_viewport_getxy function call. The Simulator TSR does not simulate viewport movement, but it does return the X and Y values to the im_viewport_getxy function: •

The X and Y parameters represent the position where the upper left corner of the JANUS viewport appear on the PC screen.

•

You cannot set X to a value larger than 60. If you could, the viewport would be positioned beyond the left edge of the PC screen.

You can change the Y value in memory by calling:

3-26

• im_viewport_end

• im_viewport_home

• im_viewport_move

• im_viewport_setxy

• im_viewport_to_cursor

• im_viewport_page_up

• im_viewport_page_down