The text of a manual · part 8 of 12
JANUS Application Simulator User's Manual, pages 71 to 80
Pages 71 to 80 of 112
The original document is the PDF (557 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Intermec J2020, Intermec JG2020, Intermec JR2020, Intermec J2010, Intermec J2050 and Intermec JG2050
Page 71
Learning About the INI File
3 link_comm_return Description
Specifies the return value after the application attempts to link a Reader Wedge and a designated COM port.
Default
0500H – Reader Wedge success
Values
See the “Reader Wedge Standard Return Values List” on page 3-40.
Function im_link_comm
Interrupt
INT 7DH
Notes
Once a JANUS application calls the im_link_comm PSK function, other PSK functions that require a link or unlink will operate as if the link were successfully established - even if you select a value for the link_comm_return parameter that indicates the im_link_comm function failed.
serial_protocol_control_return Description
Specifies the return value for the simulated im_serial_protocol_control function.
Default
0500H – Reader Wedge success
Values
See the “Reader Wedge Standard Return Values List” on page 3-40.
Function im_serial_protocol_control
Interrupt
INT 7DH
3-37
Page 72
JANUS Application Simulator User’s Manual standby_wait_return Description
Specifies the return value for the simulated im_standby_wait function.
Default
0500H – Reader Wedge success
Values
See the “Reader Wedge Standard Return Values List” on page 3-40.
Function im_standby_wait
Interrupt
INT 7DH unlink_comm_return
3-38
Description
Specifies the return value for the simulated im_unlink_comm function.
Default
0500H – Reader Wedge success
Values
See the “Reader Wedge Standard Return Values List” on page 3-40.
Function im_unlink_comm
Interrupt
INT 7DH
Page 73
Learning About the INI File
3
Communications Standard Return Values Communications standard return values are sent to a JANUS application to indicate the result of a communications function call, such as im_rx_check_status. When you customize the INI file for the Simulator TSR, you can set these four parameters to a communications return value: • rx_check_status_return • cancel_rx_buff_return • protocol_ext_status_return • cancel_tx_buff_return
Communications Standard Return Values List Code
Description
0600H
Communication operation successful
0601H
Communication buffer done
4600H
Warning buffer canceled
4601H
Communication timeout warning
4602H
Communication had no client to cancel
4603H
No protocol handler to configure
4604H
Protocol handler is not yet loaded
4605H
Protocol handler already receiving
4607H
Protocol handler not active for link request
8600H
Invalid configuration
8601H
Buffer length 0 error
8602H
Communication port is in use
8603H
Protocol error
8604H
Communication port error
8605H
Communication port is busy
8606H
Comunication request is not supported
8607H
Protocol handler already loaded
3-39
Page 74
JANUS Application Simulator User’s Manual
Code
Description
8608H
Protocol buffer error
8609H
Unknown service request
860AH
No data available
860BH
Communication utility is not loaded
860CH
Communication utility resume/suspend failure
860DH
Communication utility INT 14 is already in use
860EH
Incompatible revision between protocol handler and communication utility
860FH
Non supported communication service
8610H
Invalid EOF character
8611H
Protocol handler is not active
8612H
Buffer must be 256 bytes or larger
Reader Wedge Standard Return Values The Reader Wedge standard return values are codes that are sent to a JANUS application to indicate the result of a Reader Wedge function call, such as link_comm_return. When you customize the INI file for the Simulator TSR, you can set these six parameters to a Reader Wedge return value: • clear_abort_callback_return • command_return • link_comm_return • serial_protocol_control_return • standby_wait_return • unlink_comm_return
3-40
Page 75
Learning About the INI File
3
Reader Wedge Standard Return Values List Code
Description
0500H
Reader Wedge success
8501H
Input request error
4502H
Input timeout
4503H
No input data
8504H
Illegal reader wedge mode
0505H
No reader commands parsed
0506H
Valid reader commands parsed
8507H
Reader commands parsing error
8508H
Invalid configuration error
0509H
Accumulating reader command
050AH
Reader command override
050BH
Reader command enter accumulate
050CH
Reader command exit accumulate
050DH
Accumulate multiread labels
050EH
The application should be notified
850FH
Error in reader command edit
0510H
An ENTER reader command parsed
8511H
Unable to allocate memory for input
8512H
Protocol handler is not linked
0513H
Protected field has been parsed
8514H
Parse error on exit accumulate
8515H
Application break detected
8516H
Invalid reader wedge request
0517H
Keycode label has been parsed
0518H
Label not accepted (application is not requesting input)
0519H
Available buffers for comms link
051AH
No comms status to report
851BH
Invalid protocol for input request
051CH
Xmit buffer busy or Comm error
051DH
Exit Accumulate with Comms error
3-41
Page 76
Page 77
4 Customizing INI Files With the Editor
Page 78
Page 79
Customizing INI Files With the Editor
4
This chapter explains why you customize the initialization (INI) file and describes how to do so with the Windows-based Editor.
Why Customize INI Files? Note: Customizing the INI file is an optional process. You do not have to customize the INI file if you are satisfied with the default values in JANUSSIM.INI. The INI parameters control how the Simulator TSR simulates a JANUS reader executing an application. You can customize the parameters so the Simulator TSR mimics the conditions against which you want to test your JANUS applications. For example, if your JANUS application checks the battery’s status, you could use an INI file to mimic a low power condition and test how your application responds. Follow these steps: 1. Create a LOWBAT.INI file and customize these parameters to simulate a low power condition: • power_status_line = 0 - AC line not connected • power_status_battery = 2 - critical battery • power_status_backup = 1 - backup low • power_status_batt_life = 10 • power_status_return = 0800H - Power management success 2. Start the Simulator TSR by typing this command at the DOS prompt: janussim lowbat.ini Enter 3. Run your JANUS application. When the application issues the im_power_status function call or the 5EH interrupt, it will find that the reader is not plugged into an AC power source, the battery is critically low, and the backup battery is low. 4. Test how the application responds to this low power condition.
4-3
Page 80
JANUS Application Simulator User’s Manual
Here is the LOWBAT.INI file with the customized parameters shaded for emphasis: ; ; Filename: LOWBAT.INI ; port1_read_file = comport1.rcv port2_read_file = comport2.rcv port3_read_file = comport3.rcv port4_read_file = comport4.rcv port1_write_file = comport1.trx port2_write_file = comport2.trx port3_write_file = comport3.trx port4_write_file = comport4.trx rx_check_status_return = 0600H - Comm Operation successful protocol_ext_status_return = 0600H - Comm Operation successful cancel_rx_buff_return = 0600H - Comm Operation successful cancel_tx_buff_return = 0600H - Comm Operation successful UART_status = 30H expanded_keyboard_status = 0 - command complete kb_insert_string_status = 0 - success kb_insert_string_capacity = 255 flush_exp_keyboard_status = 0 - success warmboot_status = 0 - warmboot disabled power_status_line = 0 - AC line not connected power_status_battery = 2 - critical battery power_status_backup = 1 - backup low power_status_batt_life = 10 power_status_return = 0800H - Power management success display_contrast_level = 16 display_size_mode = 0 - 80 x 25 display_video_mode = 3 - std video mode 3 (80x25) display_scroll_mode = 1 - scroll at 16 display_viewport_lock = 0 - locked display_x_pos = 0 display_y_pos = 0 display_backlight = 0 - backlight off display_char_height = 0 - standard height characters appl_break_status = 0 - break not been made follow_cursor = 1 - follow cursor mode on control_key = 0 - control key disabled keyclick = 0 - keyclick off
4-4