The text of a manual · part 43 of 56
JANUS 2010 Hand-Held Computer (4MB) User's Manual, pages 421 to 430
Pages 421 to 430 of 556
The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2010
Page 421
Configuration Command Reference nugget
Syntax:
code39 helconital
12
SSdata Acceptable values for data are: 0 1 2 3 4 5 6
Scan:
All compatible scanners 146x CCD scanners 1500 laser scanner 151x laser scanners 1545 laser scanner Compatible Symbol scanners (with reverse polarity enabled) 155x laser scanners
One of these bar codes: All Compatible Scanners
*$+SS0*
146x CCD Scanners
*$+SS1*
*$+SS0*
*$+SS1*
1500 Laser Scanner
151x Laser Scanners
*$+SS2*
*$+SS3*
*$+SS2*
*$+SS3*
1545 Laser Scanner
Compatible Symbol Scanners
*$+SS4* *$+SS4*
*$+SS5*
*$+SS5*
155x Laser Scanners
*$+SS6* *$+SS6*
Scanner Mode Purpose:
Defines how the scanner operates when the trigger is pulled. There are two types of modes: •
One-Shot mode requires you to pull the trigger each time you want to scan a bar code. Once you scan a bar code, the scanner turns off.
•
Automatic mode allows you to pull the trigger once and scan a series of bar codes. When you release the trigger, the scanner turns off. To scan the same bar code more than once, you must release the trigger or scan a different bar code before attempting a second scan.
12-85
Page 422
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
Scanner Mode (continued) Default:
One-Shot mode
Syntax:
SBdata Acceptable values for data are: 0 1
Scan:
One-Shot mode Automatic mode
One of these bar codes: Enable One-Shot Mode
*$+SB0* *$+SB0*
Enable Automatic Mode
*$+SB1* *$+SB1*
Scanner Redundancy Purpose:
Defines the number of scans (voting) the scanner takes of the same label that must decode correctly for a good read of the label. Voting allows the reader to decode the same bar code multiple times during a single-trigger event, and to compare the decoded information a specific number of times before signaling a good read. There are three options: Low Allows the reader to accept the first good read, which speeds up reader performance. This setting is recommended when scanning good quality bar codes. Normal The reader decodes the bar code a minimum number of times in each trigger event. High The reader scans and decodes the bar code a maximum number of times in each trigger event. The specific number of comparisons depends on each bar code symbology. The high setting is recommended when scanning poor quality labels that may cause substitution errors. For example, when you scan Code 39 labels and the scanner redundancy is set to normal, two successive matching decodes in a single-trigger event are required. When scanner redundancy is set to high, three successive matching decodes in a single-trigger event are required.
12-86
Page 423
Configuration Command Reference nugget code39 helconital
Default:
Normal
Syntax:
SRdata
12
Acceptable values for data are: 0 1 2 Scan:
None Normal High
One of these bar codes: None
High
*$+SR0*
*$+SR2*
*$+SR0*
*$+SR2*
Normal
*$+SR1* *$+SR1*
Scanner Timeout Purpose:
Defines the maximum length of time the scanner stays on following each trigger pull.
Default:
Disabled (no timeout)
Syntax:
SAdata Acceptable values for data are: 0 1-60
Scan:
Disabled Shutoff time in seconds
1. Scan this bar code: Enter Accumulate Mode / Change Scanner Timeout
*+/$+SA* *+/$+SA*
12-87
Page 424
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
Scanner Timeout (continued) 2. Scan a numeric value for data from these bar codes:
*0* *0*
*2*
*1* *1*
*3*
*2*
*3*
*4*
*5*
*6*
*7*
*8*
*9*
*4*
*6*
*8*
*5*
*7*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Scanner Trigger Purpose:
Scanner trigger allows you to set level triggering or edge triggering. •
With level triggering, you pull the trigger and the laser turns on and stays on until you release the trigger.
•
In edge triggering, you pull the trigger and the laser turns on and stays on. When you pull the trigger a second time, the laser turns off. Simply releasing the trigger does not turn the laser off. If the laser is left on, the scanner timeout turns the laser off.
Default:
Level triggering
Syntax:
SCdata Acceptable values for data are: 0 1
12-88
Level triggering Edge triggering
Page 425
Configuration Command Reference nugget code39 helconital
Scan:
12
One of these bar codes: Enable Level Triggering
*$+SC0* *$+SC0*
Enable Edge Triggering
*$+SC1* *$+SC1*
SEL (Select) Purpose:
Defines the character that requests permission for the controller to send data to the polled device. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.
Default:
Disabled
Syntax:
HAdata where data can be any ASCII character.
Scan:
To disable SEL, scan this bar code: Disable SEL
*$+HA* *$+HA*
Or:
To set SEL to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set SEL
*+/$+HA* *+/$+HA*
12-89
Page 426
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
SEL (Select) (continued) 2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
SOM (Start of Message) Purpose:
SOM is the first character in a message sent to or received from the host computer. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.
Default:
Disabled
Syntax:
PEdata where data can be any ASCII character.
Scan:
To disable SOM, scan this bar code: Disable SOM
*$+PE* *$+PE*
Or:
To set SOM to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set SOM
*+/$+PE* *+/$+PE*
12-90
Page 427
Configuration Command Reference nugget code39 helconital
12
2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Stop Bits Purpose:
Sets the number of stop bits on the communications port. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.
Default:
1 stop bit
Syntax:
ICdata Acceptable values for data are: 1 2
Scan:
1 stop bit 2 stop bits
One of these bar codes: 1 Stop Bit
*$+IC1* *$+IC1*
2 Stop Bits
*$+IC2* *$+IC2*
12-91
Page 428
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
Timeout Delay Purpose:
Defines the length of time the reader waits between characters when receiving a message. When the timeout expires, an I/O error occurs. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter. If you are using User-Defined or Point-to-Point protocol, you should only set the Timeout Delay command if the baud rate is 9600 or lower. You should disable Timeout Delay if the baud rate for either of these protocols is set to 19200 or higher.
Default:
10 sec
Syntax:
IEdata Acceptable values for data are: 0 1 2 3 4 5 6 7 8
Scan:
5 ms 100 ms 500 ms 2 sec 10 sec 20 sec 40 sec 60 sec No timeout
One of these bar codes: No Timeout Delay
*$+IE8*
*$+IE0*
*$+IE8*
*$+IE0*
Timeout Delay, 100 ms
Timeout Delay, 500 ms
*$+IE1*
*$+IE2*
*$+IE1*
*$+IE2*
Timeout Delay, 2 sec
Timeout Delay, 10 sec
*$+IE3*
*$+IE4*
*$+IE3*
12-92
Timeout Delay, 5 ms
*$+IE4*
Page 429
Configuration Command Reference nugget code39 helconital Timeout Delay, 20 sec
*$+IE5* *$+IE5*
12
Timeout Delay, 40 sec
*$+IE6*
*$+IE6*
Timeout Delay, 60 sec
*$+IE7* *$+IE7*
Transmit Abort Timeout Purpose:
Defines the length of time the reader waits to receive a message if one of the following conditions is true: •
CTS is continuously false for the timeout period.
•
XOFF condition does not change within the timeout period.
•
POL not received (polling protocol) within the timeout period.
Transmit Abort Timeout is similar to the Timeout Delay configuration, but it only applies to the three conditions listed above. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter. Default:
Disabled
Syntax:
IHdata Acceptable values for data are: 0 1-65000
Scan:
Disabled Timeout in ms
To disable Transmit Abort Timeout, scan this bar code: Disable Transmit Abort Timeout
*$+IH0* *$+IH0*
12-93
Page 430
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
Transmit Abort Timeout (continued) Or:
To set a timeout value: 1. Scan this bar code: Enter Accumulate Mode / Change Transmit Abort Timeout
*+/$+IH* *+/$+IH*
2. Scan a numeric value of one to five digits for data from these bar codes:
*0* *0*
*2*
*1*
*3*
*2*
*3*
*4*
*5*
*6*
*7*
*8*
*9*
*4*
*6*
*8*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-94
*1*
*5*
*7*
*9*