The text of a manual · part 44 of 56
JANUS 2010 Hand-Held Computer (4MB) User's Manual, pages 431 to 440
Pages 431 to 440 of 556
The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2010
Page 431
Configuration Command Reference nugget code39 helconital
12
Turnaround Delay Purpose:
Defines the length of time the reader waits to respond after receiving data from the host computer. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.
Default:
0 sec
Syntax:
IGdata Acceptable values for data are: 0 1 2 3 4 5 6 7
Scan:
0 ms 1 ms 2 ms 5 ms 10 ms 20 ms 50 ms 100 ms
One of these bar codes: No Turnaround Delay
*$+IG0*
Turnaround Delay, 1 ms
*$+IG1*
*$+IG0*
*$+IG1*
Turnaround Delay, 2 ms
Turnaround Delay, 5 ms
*$+IG2*
*$+IG3*
*$+IG2*
*$+IG3*
Turnaround Delay, 10 ms
Turnaround Delay, 20 ms
*$+IG4*
*$+IG5*
*$+IG4*
*$+IG5*
Turnaround Delay, 50 ms
Turnaround Delay, 100 ms
*$+IG6*
*$+IG7*
*$+IG6*
*$+IG7*
12-95
Page 432
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
UPC/EAN Purpose:
Enables or disables the decoding of Universal Product Code (UPC)/European Article Numbering (EAN) symbology. UPC/EAN are fixed length, numeric, continuous symbologies that use four element widths. A reader that is configured to decode EAN bar codes can decode UPC, but the reverse is not true. UPC code is a subset of EAN code. To define the UPC/EAN symbology, you set up to seven digits. The fifth, sixth, and seventh digits are optional. To set the sixth digit, you must set the fifth digit. To set the seventh digit, you must set all seven digits.
Default:
First digit: Second digit: Third digit: Fourth digit: Fifth digit: Sixth digit: Seventh digit:
Syntax:
CEdata
UPC-A/EAN-13 enabled UPC-E enabled EAN-8 enabled Supplementals allowed Transmit check digit Transmit number system digit Retain leading zero for UPC-A where data must be 4 to 7 digits selected from this list:
12-96
First digit:
0 1 2
UPC-A/EAN-13 disabled UPC-A/EAN-13 enabled UPC-A only enabled
Second digit:
0 1
UPC-E disabled UPC-E enabled
Third digit:
0 1
EAN-8 disabled EAN-8 enabled
Fourth digit:
0 1
Supplementals are not allowed Supplementals are allowed
Fifth digit:
0 1
Discard check digit Transmit check digit
Sixth digit:
0 1
Discard number system digit Transmit number system digit
Seventh digit:
0 1
Discard the leading zero for UPC-A Retain the leading zero for UPC-A
Page 433
Configuration Command Reference nugget
Scan:
code39 helconital
12
To disable UPC/EAN, scan this bar code: Disable UPC/EAN
*$+CE000000* *$+CE000000*
Or:
To enable UPC/EAN: 1. Scan this bar code: Enter Accumulate Mode / Enable UPC/EAN
*+/$+CE* *+/$+CE*
2. Scan one of these bar codes to set the first digit: Disable UPC/EAN-13
Enable UPC/EAN-13
*0*
*1*
*0*
*1*
Enable UPC-A Only
*2* *2*
3. Scan one of these bar codes to set the second digit: Disable UPC-E
Enable UPC-E
*0*
*1*
*0*
*1*
4. Scan one of these bar codes to set the third digit: Disable EAN-8
Enable EAN-8
*0*
*1*
*0*
*1*
12-97
Page 434
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
UPC/EAN (continued) 5. Scan one of these bar codes to set the fourth digit: Supplementals Not Allowed
Supplementals Allowed
*0*
*1*
*0*
*1*
6. (Optional) Scan one of these bar codes to set the fifth digit: Discard Check Digit
Transmit Check Digit
*0*
*1*
*0*
*1*
7. (Optional) Scan one of these bar codes to set the sixth digit: Discard Number System Digit
Transmit Number System Digit
*0*
*1*
*0*
*1*
Note: If you discard the number system digit, one leading digit is discarded from UPC-A, UPC-E, and EAN-8, and two leading digits are discarded from EAN-13. 8. (Optional) Scan one of these bar codes to set the seventh digit: Discard Leading Zero for UPC-A
Transmit Leading Zero for UPC-A
*0*
*1*
*0*
*1*
Note: This option applies only when you enable UPC-A/EAN-13. 9. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-98
Page 435
Configuration Command Reference nugget code39 helconital
12
Viewport Movement Keys Purpose:
Allows you to use the compound function and arrow keys to move the viewport around the virtual display. You must set the Display Setup command to 25 x 80 to use the reader’s viewport. For help, see the “Display Setup” command earlier in this chapter.
Default:
Enabled
Syntax:
DVdata Acceptable values for data are: 0 1
Scan:
Disable viewport movement keys Enable viewport movement keys
One of these bar codes: Disable Viewport Movement Keys
*$+DV0* *$+DV0*
Enable Viewport Movement Keys
*$+DV1* *$+DV1*
Viewport Movement Mode Purpose:
Enables Manual or Automatic Viewport Movement mode. In Manual mode, you manually move the viewport around the reader’s virtual display. In Automatic mode, the viewport automatically follows the cursor around the reader’s virtual display. You must set the Display Setup command to 25 x 80 to use the reader’s viewport. For help, see the “Display Setup” command earlier in this chapter. Note: While you run an application, the reader reverts to Automatic Viewport Movement mode and scrolls at line 25 unless your application sets these values. When you exit the application, the reader restores your previous configuration values.
Default:
Enable Automatic Viewport Movement mode
12-99
Page 436
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
Viewport Movement Mode (continued) Syntax:
DZdata Acceptable values for data are: 0 1
Scan:
Enable Manual Viewport Movement mode Enable Automatic Viewport Movement mode
One of these bar codes: Enable Manual Viewport Movement Mode
*$+DZ0* *$+DZ0*
Enable Automatic Viewport Movement Mode
*$+DZ1* *$+DZ1*
Viewport Movement Steps Purpose:
Defines the number of horizontal and vertical steps the viewport moves when you enter a viewport up, down, right, or left command. The horizontal steps are the number of characters the viewport moves left or right. The vertical steps are the number of lines or rows the viewport moves up or down. You must set the Display Setup command to 25 x 80 before you can move the viewport. For help, see the “Display Setup” command earlier in this chapter.
Default:
10 horizontal steps and 9 vertical steps
Syntax:
DYdata Acceptable values for data are: 1-20H 1-9V
Scan:
1 to 20 horizontal steps or characters 1 to 9 vertical steps or lines
To define the number of steps: 1. Scan this bar code: Enter Accumulate Mode / Viewport Movement Steps
*+/$+DY* *+/$+DY*
12-100
Page 437
Configuration Command Reference nugget code39 helconital
12
2. Scan a one or two-digit numeric value for data from these bar codes:
*0* *0*
*2*
*1* *1*
*3*
*2*
*3*
*4*
*5*
*6*
*7*
*8*
*9*
*4*
*6*
*8*
*5*
*7*
*9*
3. Scan one of these bar codes to set the horizontal or vertical step: Horizontal Step
Vertical Step
*H*
*V*
*H*
*V*
4. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-101
Page 438
nugget code39 helconital
Page 439
nugget code39 helconital
A Reader Specifications
Page 440
nugget code39 helconital