For the Intermec J2010

Page 411

Configuration Command Reference nugget code39 helconital

12

Parity Purpose:

Sets the parity of the selected communications port. The reader uses parity for error checking in data transmissions. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.

Default:

Even

Syntax:

IBdata Acceptable values for data are: 0 1 2 3 4

Scan:

No parity Even parity Odd parity Mark parity Space parity

One of these bar codes: No Parity

Even Parity

*$+IB0*

*$+IB1*

Odd Parity

Mark Parity

*$+IB0*

*$+IB2* *$+IB2*

*$+IB1*

*$+IB3*

*$+IB3*

Space Parity

*$+IB4* *$+IB4*

12-75

Page 412

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

Plessey Purpose:

Enables or disables decoding of Plessey symbology. Plessey code is pulsewidth modulated. It includes a start character, data characters, an eight-bit cyclic check digit, a termination bar, and usually a reverse start character. The code is continuous and not self-checking. You need to configure two parameters for Plessey code: Start Code and Check Digit.

Default:

Disabled

Syntax:

CIdata Acceptable values for data are: 00 10 30 31

Scan:

Disabled Plessey with reverse start code Transmit check digit Discard check digit

To disable Plessey: Disable Plessey

*$+CI00* *$+CI00*

Or:

To set Plessey, complete these steps: 1. Scan this bar code: Plessey With Reverse Start Code

*$+CI10* *$+CI10*

2. Scan one of these bar codes to transmit or retain the check digit: Transmit Check Digit

*$+CI30* *$+CI30*

12-76

Discard Check Digit

*$+CI31*

*$+CI31*

Page 413

Configuration Command Reference nugget code39 helconital

12

POL Purpose:

Solicits or requests data from a polled device. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.

Default:

Disabled

Syntax:

HBdata where data can be any ASCII character.

Scan:

To disable POL, scan this bar code: Disable POL

*$+HB* *$+HB*

Or:

To set POL to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set POL

*+/$+HB* *+/$+HB*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-77

Page 414

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

Postamble Purpose:

Sets the postamble that is appended to any data you scan with the reader. Common postambles include cursor controls such as tabs or carriage return line feeds. Note: A postamble is not added to scanned data when you run IRL programs.

Default:

<CR>

Syntax:

AEdata Acceptable values for data are up to 25 ASCII characters. If you enter the AE command without data, the postamble is disabled. You must enclose the data within quotation marks if the data is a reserved word, such as a reader configuration command (see the example).

Scan:

To disable the postamble, scan this bar code: Disable Postamble

*$+AE* *$+AE*

Or:

To set the postamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Postamble

*+/$+AE* *+/$+AE*

2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix C. The postamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-78

Page 415

Configuration Command Reference nugget code39 helconital

Example:

12

You want to set the postamble to the letters “BV,” which also represents the Beep Volume configuration command. Enter the postamble by scanning this bar code: Set Postamble to BV

*$+AE/BBV/B* $+AE"BV"

If you omit the quotation marks, the reader interprets the command as two commands: AE to set the postamble to no characters, and BV to change the beep volume.

Preamble Purpose:

Sets the preamble that precedes any data you scan with the reader. Common preambles include a data location number or an operator number. Note: A preamble is not added to scanned data when you run IRL programs.

Default:

Disabled

Syntax:

ADdata Acceptable values for data are up to 25 ASCII characters. When you enter the AD command without data, the preamble is disabled. You must enclose the data within quotation marks if the data is a reserved word, such as a reader configuration command (see the example at the end of this section).

Scan:

To disable the preamble, scan this bar code: Disable Preamble

*$+AD* *$+AD*

Or:

To set the preamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Preamble

*+/$+AD* *+/$+AD*

2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix C. The preamble can be from 1 to 25 characters.

12-79

Page 416

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

Preamble (continued) 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Example:

You want to set the preamble to the letters “BV,” which also represents the Beep Volume configuration command. Enter the preamble by scanning this bar code: Set Preamble to BV

*$+AD/BBV/B* $+AD"BV"

If you omit the quotation marks, the reader interprets the command as two commands: AD to set the preamble to no characters, and BV to change the beep volume.

Records Per Block Purpose:

Defines the maximum number of data records transmitted per block of data. Usually files are transmitted record by record. This configuration allows you to transmit multiple records per data block. A block of data is transmitted during a single transmission, like an individual data record is normally. Note: The configured option may be overridden when you use certain communications protocols. Records Per Block will not be overridden when you use User-Defined protocol. You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.

Default:

1 record transmitted per block

Syntax:

FCdata Acceptable values for data are: 0 01-99

12-80

All records are transmitted in one block Records transmitted per block

Page 417

Configuration Command Reference nugget

Scan:

code39 helconital

12

To have all records transmitted in one block, scan this bar code: All Records = 1 Block

*$+FC0* *$+FC0*

Or:

To set the records per block: 1. Scan this bar code: Enter Accumulate Mode / Set Number of Records Per Block

*+/$+FC* *+/$+FC*

2. Scan a two-digit numeric value for data from these bar codes:

*0* *0*

*2*

*1* *1*

*3*

*2*

*3*

*4*

*5*

*6*

*7*

*8*

*9*

*4*

*6*

*8*

*5*

*7*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-81

Page 418

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

REQ (Request for Acknowledge) Purpose:

Enables or disables a request for a repeat handshake event. If you enable REQ, you must also enable AFF and NEG to have a valid configuration. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.

Default:

Disabled

Syntax:

PDdata where data can be any ASCII character.

Scan:

To disable REQ, scan this bar code: Disable REQ

*$+PD* *$+PD*

Or:

To set REQ to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set REQ

*+/$+PD* *+/$+PD*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-82

Page 419

Configuration Command Reference nugget code39 helconital

12

RES (Reset) Purpose:

Enables or disables a reset event. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.

Default:

Disabled

Syntax:

PCdata where data can be any ASCII character.

Scan:

To disable RES, scan this bar code: Disable RES

*$+PC* *$+PC*

Or:

To set RES to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set RES

*+/$+PC* *+/$+PC*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-83

Page 420

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

Scan Ahead Purpose:

Enables or disables scan ahead. If you enable this parameter, you can scan a number of labels that are held in a stack until the reader can process the data. If you disable this parameter, the reader processes each label you scan before you can scan the next label.

Default:

Disabled

Syntax:

SDdata Acceptable values for data are: 0 1

Scan:

Disabled (scan one label at a time) Enabled (scan many labels at a time)

One of these bar codes: Disable Scan Ahead

*$+SD0* *$+SD0*

Enable Scan Ahead

*$+SD1* *$+SD1*

Scanner Devices Purpose:

Identifies the type of scanner you have connected to the JANUS 2010 reader. The reader can optimize the scanning performance by using the scanner you define in this command. Note: You only need to set the Scanner Devices command when you use the COM2 port as a scanner input port. When you select a specific scanner, other scanners may not function properly.

Default:

12-84

All compatible scanners (including wands)