The text of a manual · part 41 of 56
JANUS 2010 Hand-Held Computer (4MB) User's Manual, pages 401 to 410
Pages 401 to 410 of 556
The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2010
Page 401
Configuration Command Reference nugget code39 helconital
12
IRL PSS (Program Statement Separator) Purpose:
Separates individual IRL program statements from each other. Note: Do not define PSS as the same character used for EOM. You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.
Default:
CR (carriage return)
Syntax:
XEdata where data can be any ASCII character.
Scan:
To disable PSS, scan this bar code: Disable PSS
*$+XE* *$+XE*
Or:
To set the PSS to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set PSS
*+/$+XE* *+/$+XE*
2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-65
Page 402
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
IRL Run Purpose:
Designates the end of an IRL program download and causes the reader to execute the program. The Run command takes the place of the last EOP character in the downloaded program. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.
Default:
DC2
Syntax:
XCdata where data can be any ASCII character.
Scan:
To disable IRL Run, scan this bar code: Disable IRL Run
*$+XC* *$+XC*
Or:
To set IRL Run to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set IRL Run
*+/$+XC* *+/$+XC*
2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-66
Page 403
Configuration Command Reference nugget code39 helconital
12
IRL SOP (Start of Program) Purpose:
Defines the beginning of an IRL program download from the host computer. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.
Default:
SI (shift in)
Syntax:
XAdata where data can be any ASCII character.
Scan:
To disable SOP, scan this bar code: Disable SOP
*$+XA* *$+XA*
Or:
To set SOP to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set SOP
*+/$+XA* *+/$+XA*
2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-67
Page 404
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
Key Code Look-Up Table Purpose:
You can remap up to 20 scanned characters to a keystroke equivalent.
Default:
102-key PC keyboard (no modifications)
Syntax:
WMdata where data can be any ASCII character.
Scan:
To reset the look-up table to the default setting, scan this bar code: Clear Key Code Look-Up Table
*$+WN* *$+WN*
Or:
To modify any scanned character, complete these steps: 1. Scan this bar code: Modify Key Code Look-Up Table
*+/$+WM* *+/$+WM*
2. Scan a bar code for data for the key you want to redefine. Use the “Full ASCII Bar Code Chart” in Appendix C. Note: Enclose the redefined character and ASCII value in quotes to prevent the reader from interpreting the option as a reader or configuration command (see the example). 3. Find the four-digit hexadecimal value for the key you want to assign. For help, see “Key Codes” in Appendix C. 4. Scan a bar code for each digit using the “Full ASCII Bar Code Chart” in Appendix C. 5. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-68
Page 405
Configuration Command Reference nugget
Example:
code39 helconital
12
You want to redefine the uppercase letter A to the [ (left square bracket). In the Full ASCII Table, the hex value for [ is 5B. To redefine A, enter this command: $+WM"A1A5B"
You can also change the Key Code Look-Up Table in IC.EXE. To redefine A to [ in IC.EXE 1. From the Op menu in IC.EXE, select Key Codes.
O E @
2. Select Redefine. 3. Press 4. Press
.
to move to the next field.
5. To enter the hexadecimal value for [, press 6. Press
.
-!
.
7. Exit IC.EXE and save your changes.
Keypad Caps Lock Purpose:
Turns the caps lock on and off. With the caps lock turned on, all alphabetic characters you type on the keypad will be uppercase or capital letters. By default, the reader turns the caps lock off when you boot the reader.
Default:
Caps lock off
Syntax:
KAdata Acceptable values for data are: 0 1
Scan:
Caps lock off Caps lock on
One of these bar codes: Caps Lock Off
*$+KA0* *$+KA0*
Caps Lock On
*$+KA1* *$+KA1*
12-69
Page 406
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
Keypad Clicker Purpose:
Enables or disables the keypad clicks. The reader sounds a click each time you press a key or decode a two-dimensional symbology.
Default:
Enabled
Syntax:
KCdata Acceptable values for data are: 0 1
Scan:
Disable keypad clicker Enable keypad clicker
One of these bar codes: Disable Keypad Clicker
*$+KC0* *$+KC0*
Enable Keypad Clicker
*$+KC1* *$+KC1*
Keypad Ctrl Key Functions Purpose:
Defines the functionality of the Control (
Default:
All Ctrl key functions enabled
Syntax:
KBdata
>
) key.
Acceptable values for data are: 0 1 2 Scan:
Enable Ctrl key Prohibit Ctrl-Alt-Del sequence (warm reboot) Prohibit Ctrl key combinations
One of these bar codes: Enable Ctrl Key
*$+KB0* *$+KB0*
12-70
Page 407
Configuration Command Reference nugget code39 helconital
12
Prohibit Ctrl-Alt-Del
*$+KB1* *$+KB1*
Prohibit Ctrl Key Combinations
*$+KB2* *$+KB2*
Keypad, Numeric Purpose:
Defines the ability to enable the numeric keypad from the reader keypad as described in Chapter 2, “Learning How to Use the Reader.” You can set the reader to simulate the numeric keypad on a 102-key PC keyboard. Press to enable the reader’s number pad. You can use the Keypad, Numeric command to prohibit the use of the numeric keypad if you want to avoid inadvertently enabling the number pad.
@
Default:
Permit entering number pad
Syntax:
KDdata
AA
Acceptable values for data are: 0 1 Scan:
Prohibit entering number pad Permit entering number pad
One of these bar codes: Prohibit Entering Number Pad
*$+KD0* *$+KD0*
Permit Entering Number Pad
*$+KD1* *$+KD1*
12-71
Page 408
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
LRC Purpose:
The Longitudinal Redundancy Check character is an error-checking character that you can append to transmitted and received blocks of data. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.
Default:
Disabled
Syntax:
IFdata Acceptable values for data are: 0 1
Scan:
LRC disabled LRC enabled
One of these bar codes: Disable LRC
*$+IF0* *$+IF0*
Enable LRC
*$+IF1* *$+IF1*
MSI Purpose:
Enables or disables decoding of MSI symbology. MSI code is similar to Plessey code. MSI code includes a start pattern, data characters, one or two check digits, and a stop pattern.
Default:
Disabled
12-72
Page 409
Configuration Command Reference nugget
Syntax:
code39 helconital
12
CNdata Acceptable values for data are:
Scan:
First digit:
0 1 2 3
Disabled No check digits 1 modulus 10 check digit 2 modulus 10 check digit
Second digit:
0 1
Discard check digit Transmit check digit
One of these bar codes: Disable MSI
*$+CN00* *$+CN00*
MSI Without Check Digits
*$+CN10* *$+CN10*
MSI With 1 Modulus 10 Check Digit, Discard Check Digit
*$+CN20* *$+CN20*
MSI With 1 Modulus 10 Check Digit, Transmit Check Digit
*$+CN21* *$+CN21*
MSI With 2 Modulus 10 Check Digits, Discard Check Digits
*$+CN30* *$+CN30*
MSI With 2 Modulus 10 Check Digits, Transmit Check Digits
*$+CN31* *$+CN31*
12-73
Page 410
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
NEG (Negative Acknowledge) Purpose:
Indicates a negative acknowledgment to a transmitted message. You must enable both NEG and AFF to have a valid configuration. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.
Default:
Disabled
Syntax:
PHdata where data can be any ASCII character.
Scan:
To disable NEG, scan this bar code: Disable NEG
*$+PH* *$+PH*
Or:
To set NEG to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set NEG
*+/$+PH* *+/$+PH*
2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-74