Page 391

Configuration Command Reference nugget code39 helconital

12

EOR (End of Record) Purpose:

Attaches an EOR to the end of every record of a file transmit. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter. The configured option may be overridden when you use certain communications protocols. EOR will not be overridden when you use User-Defined protocol.

Default:

Disabled

Syntax:

FBdata where data can be one or two ASCII characters.

Scan:

To disable EOR, scan this bar code: Disable EOR

*$+FB* *$+FB*

Or:

To set the EOR character to an ASCII character(s): 1. Scan this bar code: Enter Accumulate Mode / Set EOR

*+/$+FB* *+/$+FB*

2. Scan one or two bar codes for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-55

Page 392

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

Flow Control Purpose:

Regulates the data transmission through the communications port. The reader is a DTE device. Clear To Send/Request To Send (CTS/RTS) is a hardware signal flow control. The reader sets RTS high when it is ready to transmit. The reader checks CTS when it tries to transmit data. XON/XOFF response causes the reader to respond to XON/XOFF characters received while transmitting. XON/XOFF control specifies that the reader transmits XON/XOFF characters to control the incoming data flow. XON/XOFF response and control specify that the reader responds to and transmits XON/XOFF characters. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.

Default:

None

Syntax:

ILdata Acceptable values for data are: 0 1 2 3 4

Scan:

None CTS checking/RTS control XON/XOFF response XON/XOFF control XON/XOFF response and control

One of these bar codes: No Flow Control

CTS Checking/RTS Control

*$+IL0*

*$+IL1*

XON/XOFF Response

XON/XOFF Control

*$+IL0*

*$+IL2* *$+IL2*

XON/XOFF Response and Control

*$+IL4* *$+IL4*

12-56

*$+IL1*

*$+IL3*

*$+IL3*

Page 393

Configuration Command Reference nugget code39 helconital

12

Intercharacter Delay Purpose:

Defines the amount of time the reader waits before sending each character to the host. It modifies outgoing data only by slowing the speed of transmission. A character delay can be useful when the reader is communicating with a controller through a modem using full-duplex operation. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.

Default:

0 sec

Syntax:

IDdata Acceptable values for data are: 0 1 2 3 4 5 6 7

Scan:

0 ms 1 ms 2 ms 5 ms 10 ms 20 ms 50 ms 100 ms

One of these bar codes: Intercharacter Delay, 0 ms

*$+ID0*

Intercharacter Delay, 1 ms

*$+ID1*

*$+ID0*

*$+ID1*

Intercharacter Delay, 2 ms

Intercharacter Delay, 5 ms

*$+ID2*

*$+ID3*

*$+ID2*

*$+ID3*

Intercharacter Delay, 10 ms

Intercharacter Delay, 20 ms

*$+ID4*

*$+ID5*

Intercharacter Delay, 50 ms

Intercharacter Delay, 100 ms

*$+ID4*

*$+ID6* *$+ID6*

*$+ID5*

*$+ID7*

*$+ID7*

12-57

Page 394

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

Interleaved 2 of 5 Purpose:

Enables or disables decoding of Interleaved 2 of 5 (I 2 of 5) symbology. I 2 of 5 is a high-density, self-checking, continuous numeric symbology. It is mainly used in inventory distribution and the automobile industry. Enabling I 2 of 5 automatically disables Code 2 of 5.

Default:

Variable length with a check digit

Syntax:

CAdata Acceptable values for data are: 0 2-32 97 98 99

Disabled Fixed length (even number only) Variable length without a check digit Case code (6 or 14) with a check digit Variable length with a check digit

Caution Using the variable length without a check digit configuration option can cause substitution errors. Conseil Des erreurs de substitution peuvent survenir si vous utilisez la longueur variable sans option de vérification de configuration de chiffres. Scan:

One of these bar codes: Disable Interleaved 2 of 5

*$+CA0* *$+CA0*

Enable Variable Length Without a Check Digit

*$+CA97* *$+CA97*

Enable Variable Length With a Check Digit

*$+CA99* *$+CA99*

12-58

Page 395

Configuration Command Reference nugget code39 helconital

12

Enable Interleaved 2 of 5, Case Code

*$+CA98* *$+CA98*

Or:

To set Interleaved 2 of 5 to a fixed length: 1. Scan this bar code: Enter Accumulate Mode / Set Fixed Length

*+/$+CA* *+/$+CA*

2. Scan a numeric value for data from these bar codes. (Use even numbers 2-32 only)

*0* *0*

*2*

*1* *1*

*3*

*2*

*3*

*4*

*6*

*4*

*6*

*8* *8*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-59

Page 396

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

Internal Drive Reset After Battery Change Purpose:

Defines how the reader operates the Type I PC card drive after you change the NiCad battery pack. If a PC card is installed when you replace the battery pack, the reader cannot determine if the PC card has also been replaced. For help, see “Configuring the Reader to Reset the Type I Drive” in Chapter 4. There are three options: Reset card If a PC card is installed, resets the Type I PC card drive every time you replace the NiCad battery pack. Do not reset card Does not reset the Type I PC card drive when you replace the battery pack. If you do change the PC card, you need to reboot the reader. Prompt for reset If a PC card is installed, prompts you to reset the Type I PC card drive each time you replace the battery pack.

Default:

Do not reset card

Syntax:

ESdata Acceptable values for data are: 0 1 2

Reset card Do not reset card Prompt for reset

Caution If you set the “Do not reset card” option, you must reboot the reader after changing a PC card or you may lose data. Conseil Si vous réglez l’option “Do not reset card,” vous devez réinitialiser le lecteur après avoir changé une carte PC ou vous risquez de perdre des données.

12-60

Page 397

Configuration Command Reference nugget

Scan:

code39 helconital

12

One of these bar codes: Reset Card

*$+ES0* *$+ES0*

Do Not Reset Card

*$+ES1* *$+ES1*

Prompt for Reset

*$+ES2* *$+ES2*

IRL BAK (Bad Program Acknowledge) Purpose:

The reader sends a BAK to indicate that it cannot successfully download an IRL program. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.

Default:

BEL

Syntax:

ZBdata where data can be any ASCII character.

Scan:

To disable BAK, scan this bar code: Disable BAK

*$+ZB* *$+ZB*

Or:

To set BAK to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set BAK

*+/$+ZB* *+/$+ZB*

12-61

Page 398

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

IRL BAK (Bad Program Acknowledge) (continued) 2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

IRL End Program Block Purpose:

Indicates the last block of an IRL program when you download a program to the reader. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.

Default:

SO (shift out)

Syntax:

XDdata where data can be any ASCII character.

Scan:

To disable IRL End Program Block, scan this bar code: Disable IRL End Program Block

*$+XD* *$+XD*

Or:

To set IRL End Program Block to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / IRL End Program Block

*+/$+XD* *+/$+XD*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C.

12-62

Page 399

Configuration Command Reference nugget code39 helconital

12

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

IRL EOP (End of Program) Purpose:

An EOP indicates the end of an IRL program block when you download a program to the reader. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.

Default:

SYN (synchronous idle)

Syntax:

XBdata where data can be any ASCII character.

Scan:

To disable EOP, scan this bar code: Disable EOP

*$+XB* *$+XB*

Or:

To set EOP to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set EOP

*+/$+XB* *+/$+XB*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-63

Page 400

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

IRL PAK (Program Acknowledge) Purpose:

The reader sends this character to the host computer to acknowledge an IRL program that it has received. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see the “Communications Protocol, Configure” command earlier in this chapter.

Default:

RS (record separator)

Syntax:

ZAdata where data can be any ASCII character.

Scan:

To disable PAK, scan this bar code: Disable PAK

*$+ZA* *$+ZA*

Or:

To set the PAK to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set PAK

*+/$+ZA* *+/$+ZA*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-64