Page 281

Booting and Resetting the Reader nugget code39 helconital

9

11. Press any key to skip the online instructions about checking connections to the reader and putting the reader in Load mode. You already performed those tasks. The online instructions are provided for users who do not have these printed instructions. 12. When the upgrade program finishes, it indicates the upgrade was successful. Press any key to return to the DOS prompt on your host computer. The files are deleted from the temporary work space on the host computer. 13. After you return to the DOS prompt on your PC, the reader displays the message, “System Has Reset, Please Reboot.” Choose Reboot from the Boot Loader menu and press to cold boot the reader.

@

Caution When the reader performs a cold boot, all files on the physical RAM drive are destroyed. Conseil Lorsque le lecteur effectue un amorçage à froid, tous les fichiers présents sur le lecteur de la mémoire RAM physique sont supprimés. 14. Reload any files or programs you had on drives C and E. For help, see “Learning How to Change the Contents of Drive C” in Chapter 3. Note: If you are upgrading to a new version of software, do not reload the startup files and drivers you used for the previous release. 15. If the reader operates in a language other than English, you must configure the reader to use that language. Use Auto-Loader as described in Chapter 8, “Preparing the Reader for International Use.”

9-15

Page 282

nugget code39 helconital

Page 283

nugget code39 helconital

10 Troubleshooting

Page 284

nugget code39 helconital

Page 285

nu code39 helco Troubleshooting

10

This chapter describes how to solve problems that may arise when you operate the reader.

How to Use This Chapter If you have a problem operating the reader, read this chapter for a solution. For easy reference, problems are grouped into these topics: •

Powering Up or Booting the Reader

•

Operating the Reader

•

Saving the Contents of the RAM Drive

•

Networking or Communicating With the Reader

•

Running IRL Programs

•

Using PC Cards

•

Using DOS Commands and Applications

•

Using MakeDisk and PutDisk

•

Scanning Bar Code Labels

•

Problems With the NiCad Battery Pack

•

If Your Applications Refer to Specific Drive Letters

•

Upgrading Flash Cards for JANUS 2.1 Software

Caution There are no user-serviceable parts inside the reader. Opening the unit will void the warranty and may cause damage to the internal components. Conseil La reader ne contient pas de pièces révisibles par l’utilisateur. Le fait d’ouvrir l’unité annule la garantie et peut endommager les pièces internes. If you send the reader in for service, it is your responsibility to save the reader applications, data, and configuration. Intermec is responsible only for ensuring that the keypad and other hardware features match when replacing your unit.

10-3

Page 286

JANUS 2010 Hand-Held Computer User’s Manual (4MB)nugget code he lconital

Powering Up or Booting the Reader This table lists problems that may occur when you turn on, turn off, or boot the reader. Problem

L

Solution

When you press to turn on the reader, nothing happens or the reader immediately turns itself off.

Make sure the NiCad battery pack is installed correctly and the yellow battery pack locks are locked tightly.

When you turn on the reader, the power management software displays an error message.

An error occurred and the reader cannot resume operating. You can turn the reader off without losing data, provided there is sufficient battery power. The next time you turn on the reader, the error sequence repeats and the Boot Loader menu appears.

The NiCad battery pack may be discharged. Replace the battery pack with a spare charged battery pack, or charge the battery pack and try again.

If you reboot the reader, you will lose all the data in the reader’s 640K conventional memory. You can save the contents of conventional memory and reload the system flash. For help, see “Dumping the Reader’s 640K Conventional Memory” and “Loading Flash Memory” in Chapter 9. When you turn on the reader, this screen appears:

* JANUS WARNING * Was the memory card under the battery pack exchanged or modified while the battery pack was removed? If If

NO Press 1 YES Press 0

Press Enter to continue

2010U.078

10-4

You removed the NiCad battery pack while the reader was turned off. The reader has been configured to prompt you when it is turned back on to determine if you also exchanged or modified the memory card in the Type I PC card drive.

If the memory card has been changed in any way since the reader was last on, press to reset the Type I PC card drive, which helps protect data from being corrupted. Otherwise, you can press to continue without resetting the Type I PC card drive.

For help, see “Configuring the Reader to Reset the Type I Drive” in Chapter 4.

Page 287

nu code39 helco Troubleshooting

10

Powering Up or Booting the Reader (continued) Problem

Solution

When you turn on or cold boot the reader, the Boot Loader menu appears. The menu may not list all the Boot Loader commands, and the screen may include a status message. For example:

The bootstrap checks the system flash when doing a resume or cold boot. If the system flash is corrupt or there are bad checksum error messages, it brings up the Boot Loader menu. Read the status messages at the bottom of the menu:

• If you see “Bad BIOS Checksum” or a message that indicates that the system flash is corrupt, save the contents of conventional memory and reload the system flash. For help, see “Dumping the Reader’s 640K Conventional Memory” and “Loading Flash Memory” in Chapter 9.

BOOT LOADER

@ @

• If you see “Bad Saved State,” the reader may have been in

Dump Load Storage Off

Storage mode. Press Storage mode, press

Bad BIOS Checksum Please Load BIOS

2010U.181

L to reboot. If you are prompted to exit again.

@

You may also see the “Bad Saved State” message if you press the button to suspend the reader while it is booting. Press to reboot the reader. You may be able to save the contents of the RAM drive. For help, see “Saving the Contents of the RAM Drive” later in this chapter.

Caution When the reader performs a cold boot, all files on the physical RAM drive are destroyed. Conseil Lorsque le lecteur effectue un amorçage à froid, tous les fichiers présents sur le lecteur de la mémoire RAM physique sont supprimés. During a warm boot, the reader cannot finish booting and displays an error message.

><O A

If you press a key (especially or ) while the reader is booting, you may see the message, “XX Keyboard Error, Press F1 or F2,” where XX is a status code such as FA. Press to exit the error screen and the reader continues booting.

H

Caution Do not press any keys while the reader is performing a warm boot or you may lose data. Conseil N'appuyez pas sur des touches pendant que le lecteur se réamorce, sinon vous pouvez perdre des données.

10-5

Page 288

JANUS 2010 Hand-Held Computer User’s Manual (4MB)nugget code he lconital

Powering Up or Booting the Reader (continued) Problem

Solution

When the reader finishes booting, an icon remains on at the top of its display.

Contact your Intermec service representative. When the reader boots, the CPU starts all power cycles and turns all icons (except for Battery) on and off. The icons turn off very quickly as the reader passes a series of bootstrap code checks. Any icon that remains on indicates where the bootstrap code failed.

Other Boot Loader menu messages may look like this:

If you see “Bad Saved State,” the device may have been in Storage mode. Press to reboot. If you are prompted to exit Storage mode, press again.

Boot

@ @

@

L to You may also see the “Bad Saved State” message if you press suspend the device while it is booting. Press to reboot the device. You may be able to save the contents of the physical RAM drive.

Loader

Reboot Password Dump Load Resume Storage Off

Other self-explanatory messages may display on bottom of the Boot Loader menu.

Power-On Override Okay To Resume

20X0A.001

@

For messages in the following group, choose Reboot on the Boot Loader menu and press . •

“System Has Reset Please Reboot”

•

“Bad CMOS Checksum, Errors Please Reboot”

•

“DRAM Check Failed Please Reboot”

@

For the messages in the following group, choose Resume or Reboot on the Boot Loader menu and press .

10-6

•

“Keypad Fault Found Okay to Resume”

•

“Power-On Override Okay to Resume”

•

“Power-Off Timeout, Errors Okay to Resume”

•

“Power-Off Forced Okay to Resume”

Page 289

nu code39 helco Troubleshooting

10

Operating the Reader This table lists problems that may occur when you operate the reader. For example, if you have problems entering or scanning data, some solutions are listed in the table. Problem

Solution

You cannot remember the password to access the Boot Loader menu.

Contact your Intermec service representative.

When you try to start IC.EXE, the reader displays an error message indicating that there is not enough memory available to run the Configuration Manager.

If the Configuration Manager TSR is unloaded when you start IC.EXE, the reader automatically loads the TSR for you. If there is not enough conventional memory available for the TSR, the reader displays an error message. Make sure at least 50K of memory is available. For help, see “Making More Memory Available on the Reader” in Chapter 3.

You want to return to the default configuration.

Follow the instructions in “Restoring the Reader’s Default Configuration” in Chapter 5.

You see one of these error messages when you try to run an application:

If you developed an application that refers to a specific drive letter, make sure the drive letter is correct. If the drive is not correct, you can change the application to refer to the new drive letters or to use a relative path instead of an absolute path.

• “File Not Found” • “Not ready reading drive X. Abort, Retry, Fail?”

You can also use the DOS SUBSTITUTE command, as described in “If Your Applications Refer to Specific Drive Letters” later in this chapter. Note: Some drive letters on the JANUS reader were changed with software version 2.10.

While writing to a PC card in the Type II PC card drive, you turn off the reader, pull out the card, modify the card, insert it back in the reader, and turn on the reader.

The reader will continue to write to the PC card when you turn it back on. The file you were writing to is out of sequence. Your PC card may be corrupted. If you cannot access data on the card, you may need to format it.

10-7

Page 290

JANUS 2010 Hand-Held Computer User’s Manual (4MB)nugget code he lconital

Operating the Reader (continued) Problem

Solution

While writing to a PC card in the Type II PC card drive, you turn off the reader, pull out the card, and turn on the reader without a card.

You have interrupted the write process. You will lose the data you were writing to the PC card.

You cannot tell if the numeric keypad is enabled or disabled.

You can check if the numeric keypad is enabled or disabled by pressing and a number. For example, press and see what appears on the reader’s display:

You scan a reader command, such as Backlight On, and nothing happens.

O

O-

Display

Indicates This State

%

The number pad is disabled.

5

The number pad is enabled with Num Lock on.

blank

The number pad is enabled with Num Lock off.

The reader commands are disabled. Scan the Enable Override command shown below to temporarily enable all of the reader commands. You can also enable or disable reader commands with IC.EXE. For help, see “Command Processing” in Chapter 12. Enable Override

*$+DC3* *$+DC3* When you run an application, the reader scrolls at line 25 and uses Automatic Viewport Movement mode regardless of the way you configured these parameters.

If you want the reader to scroll at another line or use Manual Viewport Movement mode while running an application, you must explicitly set those parameters in the application. You can use, for example, PSK functions.

The reader decodes a bar code label in a symbology other than the label’s actual symbology.

Try scanning the bar code label again. Make sure you scan the entire label.

10-8

To ensure that the reader can operate quickly and efficiently, you should enable only the bar code symbologies that you are going to scan. If you enable multiple symbologies, the reader may on rare occasions decode a bar code according to the wrong symbology and produce erroneous results.