Page 291
nu code39 helco Troubleshooting
10
Operating the Reader (continued) Problem
Solution
The user application is not receiving the bar code input properly.
Reader Services may have been unloaded. The reader cannot decode bar code labels unless Reader Services are loaded. Verify that the IF EXIST D:\RDG.BAT CALL D:\RDG.BAT command is in AUTOEXEC.BAT, and then warm boot the reader to reload Reader Services. If you cannot load Reader Services, you may have assigned too much conventional memory to the physical RAM drives. For help, see “Deciding How Much Memory to Use for RAM Drives” in Chapter 3.
Caution Do not press any keys while the reader is performing a warm boot or you may lose data. Conseil N'appuyez pas sur des touches pendant que le lecteur se réamorce, sinon vous pouvez perdre des données. You cannot scan bar code labels.
See “Scanning Bar Code Labels” later in this chapter.
You see this message, “Configuration Manager TSR is not loaded.”
You typed cfgmgr -d to unload the Configuration Manager TSR from memory, but it has already been unloaded. No action is required.
You see this message, “Configuration Manager TSR already loaded.”
You typed cfgmgr to load the Configuration Manager TSR into memory, but it has already been loaded. No action is required.
10-9
Page 292
JANUS 2010 Hand-Held Computer User’s Manual (4MB)nugget code he lconital
Operating the Reader (continued) Problem
Solution
The Battery icon appears at the top of the reader display.
The reader displays the Battery icon when the NiCad battery pack has approximately 15 to 45 minutes of power left. If you are using a J2010, replace the battery soon. For a JANUS 2010 with RF Back, you should immediately replace or recharge the battery pack because you will soon lose RF communications.
Caution When the Battery icon appears, save your data and replace the battery pack as soon as possible. Conseil Quand l’icône de la pile apparaît, enregistrez vos données et remplacez le jeu de piles aussitôt que possible, sinon vous pourriez perdre des données. You see all these symptoms:
The NiCad battery pack charge is critically low.
• The Battery icon remains on.
Save your data. Replace the battery pack with a spare charged battery pack, charge the battery pack, or attach an external power supply.
• The reader chirps every 5 seconds for 1 minute and then turns off. • The reader double-beeps when you enter or scan data, and double-clicks when you press any key. You see all these symptoms:
• The Battery icon is not displayed. • The reader chirps every 15 seconds for 1 minute and then turns off. • The reader double-beeps when you enter or scan data, and double-clicks when you press any key. • The Backup Battery screen appears each time you turn the reader on.
10-10
The laser scanner (or wand) and RF communications are turned off 15 seconds after the first chirp.
Keep a charged NiCad battery pack installed in the reader. You can also attach an external power supply. Save all your data and back up all the files that are on drive E. Reset the date and time to clear the low backup battery icon if the device experienced a deep discharge of the backup battery. Contact your Intermec service representative to replace the lithium bridge battery.
Page 293
nu code39 helco Troubleshooting
10
Operating the Reader (continued)
L
Problem
Solution
The reader appears to be locked up and you cannot enter data.
Press to turn off the reader. If the reader will not turn off, see the next problem in this table for help. Press to turn on the reader. If the reader displays the Boot Loader menu with the message “Bad Saved State,” press to cold boot the reader. You may be able to save the contents of the physical RAM drive. For help, see “Saving the Contents of the RAM Drive” later in this chapter.
@
L
Caution When the reader performs a cold boot, all files on the physical RAM drive are destroyed. Conseil Lorsque le lecteur effectue un amorçage à froid, tous les fichiers présents sur le lecteur de la mémoire RAM physique sont supprimés. The reader appears to be locked up or is beeping every 10 seconds. When you press to turn off the reader, it does not turn off.
L
L -E
L
Press - to turn off the reader. It may take a few seconds before the reader turns off. When you press to turn on the reader, it displays the Boot Loader menu. Read the status messages at the bottom of the menu. If the messages tell you to resume, choose Resume from the Boot Loader menu. If the messages tell you to reboot, choose Reboot from the Boot Loader menu to cold boot the reader. You may be able to save the contents of the physical RAM drive. For help, see “Saving the Contents of the RAM Drive” later in this chapter.
Caution When the reader performs a cold boot, all files on the physical RAM drive are destroyed. Conseil Lorsque le lecteur effectue un amorçage à froid, tous les fichiers présents sur le lecteur de la mémoire RAM physique sont supprimés.
10-11
Page 294
JANUS 2010 Hand-Held Computer User’s Manual (4MB)nugget code he lconital
Operating the Reader (continued) Problem
Solution
The reader displays the Boot Loader menu.
The reader displays the Boot Loader menu in response to several error conditions:
L or removing the • You turned off the reader (by pressing NiCad battery pack) while the reader was performing a warm boot. • You removed and replaced a discharged NiCad battery pack, instead of inserting a charged battery pack. • You ran an application on the reader that masks the nonmaskable interrupt (NMI). While this is acceptable on a PC, it is not acceptable on a reader. • There may be another problem with the reader. Read the status messages at the bottom of the menu. If the messages tell you to resume, choose Resume from the Boot Loader menu. If the messages tell you to reboot, choose Reboot from the Boot Loader menu to cold boot the reader. You may be able to save the contents of the physical RAM drive. For help, see “Saving the Contents of the RAM Drive” later in this chapter.
Caution When the reader performs a cold boot, all files on the physical RAM drive are destroyed. Conseil Lorsque le lecteur effectue un amorçage à froid, tous les fichiers présents sur le lecteur de la mémoire RAM physique sont supprimés. You need to cold boot the reader and you want to save the contents of drive E, the physical RAM drive.
10-12
For help, see “Saving the Contents of the RAM Drive” later in this chapter.
Page 295
nu code39 helco Troubleshooting
10
Operating the Reader (continued) Problem
Solution
All the files on drive E have been erased.
The contents of drive E, the physical RAM drive, are destroyed when you perform these tasks: • You cold boot the reader. • You load the reader’s flash memory. • You put the reader in Storage mode. • You execute CONFIG.SYS after changing the command that creates the RAM drive.
L or removing the NiCad • You turn off the reader (by pressing battery pack) while the reader is performing a warm boot. • You removed and replaced a discharged NiCad battery pack, instead of inserting a fully charged battery pack. • You run an application on the reader that masks the nonmaskable interrupt (NMI). While this is acceptable on a PC, it is not acceptable on a reader. You must restore or copy your files to drive E.
10-13
Page 296
JANUS 2010 Hand-Held Computer User’s Manual (4MB)nugget code he lconital
Saving the Contents of the RAM Drive When you cold boot the reader, the contents of drive E, the physical RAM drive, are normally destroyed. You may be able to save the contents of the RAM drive by using this procedure. To save the contents of the physical RAM drive 1. From the Boot Loader menu, choose Reboot. Caution When the reader performs a cold boot, all files on the physical RAM drive are destroyed. Conseil Lorsque le lecteur effectue un amorçage à froid, tous les fichiers présents sur le lecteur de la mémoire RAM physique sont supprimés. 2. Press
?
as soon as you see the RAM memory test message:
BIOS Ver x.xxx Copyright 1992-199x All Rights Reserved 00120K RAM Passed
Note: You must press
?
before the memory counter reaches 00640K RAM Passed.
3. The reader continues booting. At the DOS prompt, enter this command: dir e:
If the contents of drive E are displayed, you can continue using the reader. If the contents of drive E are destroyed, you must restore or copy your files to drive E.
10-14
Page 297
nu code39 helco Troubleshooting
10
Networking or Communicating With the Reader This table lists problems that may occur when the reader is communicating with another device. Note: If you have problems with your RF network, see your JANUS RF documentation. Problem
Solution
Communications problems occur only when you connect the optical link adapter to a reader and no external power source is attached.
The reader may not be in good contact with the optical link adapter. Inspect the spring contacts and contact surfaces on the optical link adapter for signs of corrosion or contamination. If necessary, clean the contacts with a cotton swab and an alcohol-based solvent. Other solvents may damage the plastic housing.
The communications application cannot communicate.
Verify that the reader and the other device are using the same communications protocol and parameter settings. If they do not match, change them and restart the communications application. Make sure the reader’s optical port, communications dock, and optical link adapter are clear of foreign material. Wipe the optical port window with a damp cloth to remove any material that may be blocking the light from the LEDs. You may need to reset the UART FIFO control register. For help, see “Specifying a Value for the FIFO Control Register” in Chapter 6.
You attempt to load PHIMEC, and the reader displays the message, “Comm port not available.”
The PHIMEC protocol handler has not been loaded into memory. You attempted to load PHIMEC to a COM port other than COM1 or COM2. Load the protocol handler again, specifying COM1 or COM2. For help, see “Loading and Unloading a Protocol Handler” in Chapter 6.
When you use the Multi-Drop protocol and 19.2 bps baud rate, the communications application times out or waits indefinitely on a receive request, and the 9154 Multi-Drop Line Controller’s fault light turns on.
The packets are too large (over 30 bytes) for the JANUS reader to handle at the 19.2 bps baud rate. Lower the baud rate to 9600 bps.
10-15
Page 298
JANUS 2010 Hand-Held Computer User’s Manual (4MB)nugget code he lconital
Networking the Reader (continued) Problem
Solution
The communications application seems to stop executing or lock up.
The reader may have lost its connection with the communications dock, optical link adapter, or other device. Verify that the reader is still connected to the other device. Make sure all the cables are firmly connected to each device. If you are using a communications dock, make sure the reader is placed correctly in the reader slot. If the reader was disconnected, restart the communications application. If it is still locked up, warm boot the reader. Check the communications protocol you configured and make sure you specified timeouts.
Caution Do not press any keys while the reader is performing a warm boot or you may lose data. Conseil N'appuyez pas sur des touches pendant que le lecteur se réamorce, sinon vous pouvez perdre des données. You experience problems with the reader display when you run terminal emulation (TE) on the reader. For example, the prompt disappears after you run a program.
When you run TE on the reader, the CONFIG.SYS file loads ANSI.SYS. ANSI.SYS interacts with IM_DISP.EXE, causing unpredictable effects on the reader’s display.
You may experience problems with your RF network, such as:
If you have any problems with your RF network, see your JANUS RF documentation.
• The RF option is not listed in the Com menu of IC.EXE. • The RF protocol handler (RFPH) did not load correctly. • The Connect icon turns off.
10-16
Remark out IM_DISP.EXE in the AUTOEXEC.BAT file while you use TE. For help editing AUTOEXEC.BAT, see “Learning How to Change the Contents of Drive C” in Chapter 3.
Page 299
nu code39 helco Troubleshooting
10
Running IRL Programs
@
When an IRL error occurs, the reader beeps and displays an error message. to clear the message and continue. The types of error messages are: Press Receive error This error occurs when the reader is receiving a message or protocol characters from the host. Transmit error This error occurs when the reader is transmitting a message or protocol characters to the host. Syntax error This error occurs when the reader is performing a syntax check on a program before running the program. If a program statement is invalid, the error message lists the program statement and the problem. Edit the program for syntax errors and run it again. Runtime error This error occurs when the reader is executing a program. The program ignores nonfatal errors. If it is a fatal error, the reader exits the program and returns to the IRL Desktop or DOS prompt. This table lists the error beep sequences and their meanings: Sequence
Meaning
Three low beeps
Syntax or compile error
Low beep, high beep, low beep
Nonfatal runtime error
Three high beeps
Fatal runtime error
Note: The JANUS reader does not beep to indicate transmit or receive errors. The next table lists problems that may occur when you run IRL programs on the reader.
10-17
Page 300
JANUS 2010 Hand-Held Computer User’s Manual (4MB)nugget code he lconital
Problem
Solution
The reader displays “Executing...” on power up or prompts you for data on power up.
An IRL Program is running. Type or scan this Exit IRL Program command: Exit IRL Program
*/$* */$*
There is not enough memory to run your IRL program.
You need to free more conventional memory or run the program without running the IRL Desktop. For help, see “Freeing Enough Memory to Run an IRL Program” in Chapter 7.
When you try to start the IRL Desktop, the reader displays an error message indicating that there is not enough memory available to run the Configuration Manager.
If the Configuration Manager TSR is unloaded when you start the IRL Desktop, the reader automatically loads the TSR for you. If there is not enough conventional memory available for the Configuration Manager TSR, the reader displays an error message. Make sure at least 50K of memory is available.
The reader is locked up in an IRL program.
Perform the application break sequence, as described in “Breaking Out of an Application” in Chapter 9.
You are having problems trying to download an IRL program.
Make sure you have performed all these steps: • You configured the communications protocol correctly on the reader and host. For help, see “Configuring the Communications Protocols” in Chapter 6. • You activated the communications protocol. For help, see “Activating One Communications Protocol” in Chapter 6. • You loaded the protocol handler. For help, see “Loading and Unloading a Protocol Handler” in Chapter 6. • You are in the IRL Desktop, at the main menu, with no commands selected.
You have trouble running an IRL program with Interlnk.
10-18
You cannot run an IRL program over an Interlnk connection.