Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 28 of 56

JANUS 2010 Hand-Held Computer (4MB) User's Manual, pages 271 to 280

Pages 271 to 280 of 556

The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec J2010

Page 271

Booting and Resetting the Reader nugget code39 helconital

9

Resetting the Reader Resetting the reader can involve forcing the reader to turn off, or stopping applications and clearing the reader’s conventional memory.

L does not clear the reader’s conventional Note: Turning off the reader by pressing memory. When you turn the reader back on, it resumes operating just as it was before you put it in Suspend mode.

Forcing the Reader to Turn Off

L -E L

L

If the reader will not turn off when you press , you can force the reader to - . It may take a few seconds before the reader turn off by pressing turns off. Later, when you press to turn the reader on, the Boot Loader menu appears. From the menu, you can dump the contents of conventional memory to another computer and/or you can cold boot the reader. For help, see “Dumping the Reader’s 640K Conventional Memory” later in this chapter, and then see “Cold Booting the Reader” earlier in this chapter.

Breaking Out of an Application If the application you are running becomes locked in an infinite loop, you can break out of that application without cold booting. The procedure involves setting a flag, called the application break bit, in the reader. Applications check the application break bit when you turn on the reader to determine if they should resume running. If the bit is set to 1, the programs will not resume. IRL applications automatically check the application break bit. If you are creating your own applications in C or Basic, you should make each application check this bit every time the reader is turned on. See your JANUS PSK reference manual to learn how to check the application bit. Note: If your C or Basic application is locked in an infinite loop and does not check the application bit, you can cold boot the reader to break out of the application.

9-5

Page 272

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital To break out of an application

L I B

L

1. Press to turn off the reader. If you must force the reader to turn off, see the previous section. 2. Press 3. Press 4. Press

-

- .

to set the application break bit in the reader.

to turn on the reader.

If the application checks the application break bit, it should take appropriate action when it detects that the bit has been set. If the application does not check the application break bit, it will resume running. You may have to cold boot the reader to break out of this application. For help, see “Cold Booting the Reader” earlier in this chapter.

Displaying the Boot Loader Menu The Boot Loader menu appears when you enter a designated key combination, the system flash is corrupt, the BIOS checksums fail, or the reader cannot resume. From the Boot Loader menu, you can perform advanced reader commands, as described later in this section. To display the Boot Loader menu 1. Press 2. Press 3. Press 4. Press

L I B

L to turn off the reader. -

- .

.

to turn on the reader.

If you do not press a key within 60 seconds after a screen is displayed, the reader automatically shuts off and you have to start over at Step 1. 5. The reader may prompt you for a password. If so, you must enter the password before you can display the Boot Loader menu. Type the password. You are allowed three attempts to type the password correctly. If you fail, the reader does not display the Boot Loader menu. Instead, the reader resumes normal operation. Note: The reader is shipped from the factory with the password disabled.

9-6

Page 273

Booting and Resetting the Reader nugget code39 helconital

9

6. The Boot Loader menu appears.

BOOT LOADER Reboot Password Dump Load Resume Storage Off

2010U.054

The Boot Loader menu lists seven commands and displays status messages or checksum messages at the bottom of the screen. The commands are: Reboot This command lets you cold boot the reader. A cold boot clears conventional memory and destroys all buffered data. For help, see “Cold Booting the Reader” earlier in this chapter. Password This command lets you enable or disable a password that all users must enter to display the Boot Loader menu. For help, see “Limiting Access to Advanced Reader Commands” later in this chapter. Dump This command lets you transmit the lower 640K of memory out through COM1. You might use this feature when the reader is not functioning and you need to save the contents of conventional memory. For help, see “Dumping the Reader’s 640K Conventional Memory” later in this chapter. Load This command lets you load the reader’s flash memory from a host computer connected to a serial port. You may reload the default flash memory to correct an error condition or you may upgrade the reader’s software. For help, see “Loading Flash Memory” later in this chapter. Resume This command lets you exit the Boot Loader menu and resume operating as you were before you displayed the Boot Loader menu. For example, if the reader was executing an application, the application continues. If there is a bad checksum or the flash is corrupt, the reader cannot resume. For help, see “Powering Up or Booting the Reader” in Chapter 10. Storage This command lets you put the reader in Storage mode, which helps preserve the life of the bridge battery. All data stored in RAM is lost when you enter Storage mode. You should place the reader in Storage mode if you are not going to use it for one week or more. For help, see “Using Storage Mode to Preserve the Bridge Battery” later in this chapter.

L

Off This command lets you exit the Boot Loader menu and put the reader into to turn the reader back on, the reader Suspend mode. When you press resumes normal operation. For help, see “Turning the Reader On and Off” in Chapter 1.

9-7

Page 274

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

Limiting Access to Advanced Reader Commands You can set a password on the reader to limit access to advanced reader commands. Only users who correctly type the password can display the Boot Loader menu and exit from Storage mode. If you lose or forget the password, call your Intermec service representative. To set the password

L I B

L

1. Display the Boot Loader menu: a. Press b. Press to turn off the reader.

c. Press

-

- .

d. Press

.

to turn on the reader.

e. Type the password if the reader prompts you to do so. If you fail to enter the correct password after three attempts, the reader resumes normal operation. 2. The Boot Loader menu appears. Press

BOOT

E until you highlight Password.

LOADER

Reboot Password Dump Load Resume Storage Off

2010U.055

3. Press

@

. The PASSWORD screen appears.

PASSWORD Please

Type

Password

*****

Enter ESC

Continue Quit to to

2010U.079

9-8

Page 275

Booting and Resetting the Reader nugget code39 helconital 4. Type the new password and press seven characters.

@

9

. Your password can contain up to

5. Type the new password again for verification and press

@

.

If you type the password incorrectly, you receive an error message and you need to repeat Steps 4 and 5. 6. Select Resume from the Boot Loader menu. The reader resumes operating. You will be prompted for this password when you attempt to display the Boot Loader menu or exit Storage mode. To disable the password

E

1. Display the Boot Loader menu. For help, see the previous set of steps.

@ @

2. At the Boot Loader menu, press 3. Press until you highlight Password.

. The PASSWORD screen appears.

4. Press twice without typing any other characters. This action disables the password by creating a null password. 5. Select Resume from the Boot Loader menu.

Using Storage Mode to Preserve the Bridge Battery If you are not going to use the reader for one week or more, you must put it in Storage mode to preserve the life of the lithium bridge battery. While the reader is in Storage mode, the NiCad battery pack must be removed; otherwise, the reader slowly drains the battery pack and bridge battery. Caution All data in conventional memory will be lost when you put the reader in Storage mode. Conseil Toutes les données dans la mémoire conventionelle perdront lorsque vous mettez le lecteur en mode de stockage.

9-9

Page 276

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital To put the reader in Storage mode

L I B

L

1. Display the Boot Loader menu: a. Press b. Press c. Press d. Press to turn off the reader. -

- .

.

to turn on the reader.

e. Type the password if the reader prompts you to do so. If you fail to enter the correct password after three attempts, the reader resumes normal operation. You will be prompted for this password again when you exit Storage mode. 2. The Boot Loader menu appears. Press

E until you highlight Storage.

BOOT LOADER Reboot Password Dump Load Resume Storage Off

3. Press

@

2010U.056

. The reader goes into Storage mode and shuts off.

4. Remove the NiCad battery pack. For help, see “Removing the Battery Pack” in Chapter 2. The reader does not enter Storage mode until you remove the battery pack. To exit Storage mode 1. Install the reader’s NiCad battery pack. For help, see “Installing the Battery Pack” in Chapter 2. 2. Press

L to turn on the reader.

3. Type the password if the reader prompts you to do so. The Boot Loader menu appears.

9-10

Page 277

Booting and Resetting the Reader nugget code39 helconital

9

4. From the Boot Loader menu, select Reboot.

BACKUP

BATTERY

Backup Battery Tests Good Storage

Mode is

On

Please Press Enter to Continue Esc to Go Off

2010U.030

The reader begins rebooting, displays the BACKUP BATTERY screen, and asks if you want to exit Storage mode.

@

5. Press to exit Storage mode, continue booting the reader, and return to the DOS prompt.

?

the reader remains in Storage mode. Immediately remove the Note: If you press battery pack, as described in Chapter 2.

Dumping the Reader’s 640K Conventional Memory If you cannot resume the reader, you may need to cold boot the reader or load flash memory to resolve the error condition. However, all data in conventional memory will be lost when you perform either of these tasks. You can save the contents of the reader’s 640K conventional memory by dumping it to a host computer. The host computer must be running a communications program that can receive and store the data from the reader’s memory. To dump the reader’s 640K conventional memory to a host computer 1. Connect the reader to a host computer using the optical link adapter or the communications dock. The reader transmits and receives data at 4800 baud, no parity, 8 data bits, and 1 stop bit. 2. Run a communications program, such as Crosstalk, that saves data on the host computer. This program is not provided with the reader.

9-11

Page 278

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

L I B

L

3. Display the Boot Loader menu: a. Press b. Press c. Press d. Press to turn off the reader. -

- .

.

to turn on the reader.

e. Type the password if the reader prompts you to do so. If you fail to enter the correct password after three attempts, the reader resumes normal operation.

@

4. The Boot Loader menu appears. Press . press

BOOT

E until you select Dump, and then

LOADER

Reboot Password Dump Load Resume Storage Off

2010U.057

The reader dumps data from low memory (640K and below) through COM1 to the host computer. The data is transmitted in Intel hexadecimal object file format. 5. A record counter on the reader display counts the data as it is transmitted to the host computer. The record counter stops updating when the reader is finished downloading the data.

@

6. Choose your next step. You can cold boot the reader by choosing the Reboot command and pressing . Then you can use the reader. If you dumped the 640K because the Boot Loader menu displayed the “Bad BIOS Checksum” error message or because the flash memory is corrupted, you must load the flash memory now. For help, see the next section, “Loading Flash Memory.”

9-12

Page 279

Booting and Resetting the Reader nugget code39 helconital

9

Loading Flash Memory You can download all of the reader’s flash memory from a host computer if the Boot Loader menu displays the “Bad BIOS Checksum” error message, if the flash memory is corrupted, or if you need to upgrade the reader’s software. Loading flash memory replaces: • drive C, the 512K ROM drive resident in flash memory.

• drive D, the 2MB ROM drive.

• the 256K flash system image.

Also, because you will reboot the reader near the end of this process, the contents of the physical RAM drive (drive E) will be destroyed. Caution When you load the reader’s flash memory, all data in conventional memory will be lost. Conseil Lorsque vous chargez la mémoire flash du lecteur, vous perdez toutes les données de la mémoire conventionnelle.

To load the reader’s flash memory 1. Decide if you want to save the contents of conventional memory. If so, you must perform the steps in the previous section, “Dumping the Reader’s 640K Conventional Memory,” now. 2. Decide if you want to save any files on drives C and E, such as customized startup files, applications, or configuration files. If so, you must copy the files to a PC card, another reader, or a host computer now. For help, see “Running Interlnk to Transfer Files” in Chapter 6. 3. Connect the reader to a host computer using an optical link adapter or communications dock. Use a null modem RS-232 cable to attach the accessory to the host computer. This cable is the same one you would use for Interlnk. 4. Connect a power supply to the communications dock or optical link adapter. 5. Press

L to turn on the reader.

9-13

Page 280

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

L I B

L

6. If the Boot Loader menu does not appear, follow these steps to display it: a. Press b. Press c. Press d. Press to turn off the reader. -

- .

.

to turn on the reader.

e. Type the password if the reader prompts you to do so. If you fail to enter the correct password after three attempts, the reader resumes normal operation. 7. At the Boot Loader menu, press

Boot

E until you select Load.

Loader

Reboot Password Dump Load Resume Storage Off

8. Press

@

2010U.058 to execute the Load command.

9. Insert companion disk 1 into a disk drive on the host computer. 10. On your host computer, type the Upgrade command as follows:

source:\upgrade /com_port source: destination: where: source is the disk drive on the host computer where you inserted the Boot Utilities companion disk 1.

com_port is the number of the serial COM port on the host computer that the reader is connected to.

destination is the drive on the host computer that you are using as a temporary work space while installing the loader and flash files. The drive must have at least 3.5MB of free disk space.

For example, if the disk is inserted in the host’s drive A, the host’s drive C is your temporary work space, and the reader is connected to the host’s COM1, type this command on the host computer and press :

@ a:\upgrade /com1 a: c: The upgrade program begins executing. It takes a little over 10 minutes to update or upgrade all of the reader’s flash memory.

9-14