Page 41

Running the Installation Utility

3

6. Press F10 to accept your selections. A message box prompts you to enter the JANUS 2020 Boot Utilities companion disk. Insert the disk and press any key to continue. Insert the Boot Utilities Companion Disk in A: or B:

7. A message box prompts you to confirm the letter of the drive containing the disk. Use the spacebar to toggle between drives A and B. Press Enter to confirm the disk location. Boot Utilities Companion Disk is in Drive A:

8. A message box appears prompting you to insert the Installation Utility disk. Insert the disk and press any key to continue. Insert the Installation Utility Disk in A:

9. The Radio Parameters screen appears. Enter the information in the fields.

10. Press F10 to exit the screen and save your changes. The Installation and Configuration Tasks screen indicates the progress of the installation. If you are doing an FPT Customer Application, a message box will appear prompting you to insert the FTP stack disk. Insert the disk and press any key. Please Insert the “FTP Stack Disk” in Drive A.

Shelling Out to DOS to Modify the JANUS Drive Images When the Installation Utility has created the new drive C and drive D file structures, the following message appears. Shell out to DOS before JANUS images built? (Y/N)

3-7

Page 42

JANUS 2.4 GHz Installation Utility User’s Manual (4MB)

If you need to modify your JANUS images to create custom .INI files, add your application, or set a security ID, choose Y. If you do not need to modify your JANUS images, choose N. To use the shell out feature 1. Press any key on your PC keyboard. You go to a DOS prompt on your host PC. 2. Use DOS commands or a DOS file editor to modify your files in \IM_FLASH\DRIVEC and \IM_FLASH\DRIVED. 3. When you have modified the files for your JANUS drive images, type exit and press Enter to return to the Installation Utility. If the files you want to add to the directories exceed the capacity of the JANUS drive C or drive D, this message appears when you type exit at the DOS prompt. Too many files, Shell out to reduce ? (Y/N)

To correct this problem, choose Y to shell out to DOS and delete files from \IM_FLASH\DRIVEC to create enough free disk space.

Downloading the Modified JANUS Drive Images The Installation Utility creates and then downloads the modified JANUS drive C and drive D images. This process can take from 5 to 10 minutes. To download the modified JANUS images 1. On the host PC, a message box appears asking if you want to change the baud rate for the Interlnk connection. Choose Y to change the baud rate to 19200, 38400, or 115200. Choose N to keep the baud rate at 57600. Set Baud Rate for Loader (Default = 57600)? (Y/N)

If you choose Y, select the baud rate. Use the spacebar to toggle the options. Press Enter to confirm the baud rate selection.

3-8

Page 43

Running the Installation Utility

3

2. Another message box appears asking if you want to change the serial port where the JANUS device is connected to the host PC. Choose Y to change the serial port. Choose N to keep the same serial port you selected when you downloaded the default drive images. Change Serial Port ? (Y/N)

If you choose Y, select the COM port. Use the spacebar to toggle between COM1, COM2, COM3, and COM4. Press Enter to confirm the serial port selection.

3. If the Boot Loader menu is not on the JANUS screen, use these steps. a. Press b. Press c. Press d. Press

L IB

L to place the JANUS device in a suspend state. .

.

to turn the JANUS device on again.

4. From the Boot Loader menu, select LOAD and press

@

.

5. If the password is set, the Password screen prompts you to type in the password. You are allowed three tries to enter the password. Note: The JANUS device comes from the factory with the password disabled. 6. Press any key on your PC keyboard. The Janus 2000 Flash Loader screen appears. This screen provides status information on the download process. On the JANUS screen, you see the same status information. When the Installation Utility finishes downloading the new images, a flashing message box on the host PC informs you that the flash programming on the JANUS device is complete. This message appears on the JANUS screen. Calculating Checksum Checksum Good

7. Press any key on your PC keyboard to continue. Another message box informs you that the installation process was successful. 8. Press any key on your PC keyboard to continue.

3-9

Page 44

JANUS 2.4 GHz Installation Utility User’s Manual (4MB)

9. A message box asks you if you want to do another installation. Choose Y, if you want to configure another JANUS device. Follow the instructions for “Configure Multiple JANUS RF Devices” in the next section. Or, choose N, if you have no more JANUS devices to configure and you want to exit the Installation Utility. Follow the instructions for “Restoring the Host PC to the Original Configuration” later in this chapter. Note: Test the device to make sure it is configured correctly before exiting the Installation Utility or configuring another JANUS device. If the device is not configured correctly, choose Y and make the necessary changes. If you configure your JANUS device to run terminal emulation software, a terminal emulation session will start after installation is completed and you reboot the device.

Configuring Multiple JANUS RF Devices 1. A message box appears asking you if you want to install the same network/protocol. Choose Y to install the same TE application or SPX/IPX protocol. Choose N to install another application. For example, if you installed Intermec TNVTXXX TE on your JANUS device, the message box contains this message: Another Intermec TNVTxxx TE Installation? (Y/N)

2. If you choose N, the Select a Network/Protocol screen appears. Use the arrow key to select the type of software that you want to install on the device and press Enter. 3. In the Installation Options screen, make any necessary changes to the fields. Press F10. The Radio Parameters screen appears. 4. In the Radio Parameters screen, make any necessary changes to the fields. Press F10. 5. A message box appears asking if you want to use the shell out feature. Choose Y if you need to make changes to your JANUS drive images. When you are finished modifying the files for your JANUS drive images, type exit and press Enter to return to the Installation Utility. Or, choose N. Shell out to DOS before JANUS images built? (Y/N)

6. Make sure the next JANUS device that you want to configure is connected to the host PC. 7. Follow Steps 1 through 9 in the previous procedure, “Downloading the Modified JANUS Drive Images.”

3-10

Page 45

Running the Installation Utility

3

Restoring the Host PC to the Original Configuration 1. When you finish configuring JANUS devices, choose N when a message box asks you if you want to do another installation. 2. A message box asks you if you want to delete files generated by the install. If you want to delete all of the files that were created by the Installation Utility, choose Y. If you want to save these files in the subdirectories on the host PC, choose N. The Installation Utility creates batch files in these subdirectories that will facilitate further modification to the JANUS drive images. For help using these batch files, see “Configuring Multiple JANUS RF Devices Using Batch Files” in Appendix B. Do you want to delete the files generated by the install? (Y/N)

You have successfully installed the network software on your JANUS devices.

3-11

Page 46

This page is a scan with no text; see it in the PDF.

Page 47

4 Troubleshooting

Page 48

This page is a scan with no text; see it in the PDF.

Page 49

Troubleshooting

4

The troubleshooting chapter provides you with information on how to troubleshoot the Installation Utility.

General Problems This table lists general troubleshooting problems you may have while using the Installation Utility. Use the problem and solution columns to help you correct the problem. Symptom

Problem

Solution

The JANUS device is overheating.

The application you are running on the JANUS device is sending too many packets to the host.

Try reducing the number of packets sent to 2 or 3 packets per second.

You may not have loaded all the Novell network software subdirectories.

1.

Make sure the Novell network software on your host PC has the correct directory structure.

2.

Reinstall the Novell network software on your host PC and rerun the Installation Utility.

Or, The JANUS device seems to be working better in a cold environment than a warm environment. The Novell network software on your device is not running properly.

You have too many files in your Novell network software subdirectories.

You may have answered ‘Yes’ to Windows support when loading the Novell network software on your host PC.

Reinstall the Novell network software and answer ‘No’ to Windows support.

You are missing some of the files on the backup copy of the Installation Utility disk or the Boot companion disk.

You may not have copied all the subdirectories when you were making the backup copy of the Installation Utility disk.

Recopy the disks using DISKCOPY.

You created a custom configuration file and it disappeared.

You may have saved the custom JANUS.INI file to drive E and performed a cold boot on the device.

Recreate the custom configuration file and save the file to drive C.

You saved a custom configuration file to drive C and the device cannot find it.

You may not have updated the path for the JANUS.INI in your AUTOEXEC.BAT.

Change the pathname to the JANUS.INI in your AUTOEXEC.BAT file.

Change the pathname to the JANUS.INI in your AUTOEXEC.BAT file.

4-3

Page 50

JANUS 2.4 GHz Installation Utility User’s Manual (4MB)

Error Messages You may encounter error messages while running the Installation Utility. This table lists the error messages in alphabetical order. If an error message appears on your screen, locate it in the table and use the problem and solution columns to help you correct the error. Error Message

Problem

Solution

C: is an Invalid Drive (where C: is scratch drive specified by user).

You did not specify a valid drive for your scratch drive.

Make sure that the drive letter that you specify is a valid physical hard drive.

Channel must be a number between 1 and 15.

You did not select a valid channel.

Select a number between 1 and 15 for the channel.

Creattemp() ERROR: Path or file name not found.

The system could not find the \NWCLIENT\NLS directory on the scratch drive of the host PC. You may not have loaded all the Novell network software subdirectories.

1.

Make sure the NetWare Client for DOS software on the scratch drive of your host PC has the directory structure listed in the section “Modifying the JANUS Drive Images” in Chapter 1.

2.

Reinstall NetWare Client for DOS on your host PC and rerun the Installation Utility.

Creattemp() ERROR: Permission denied.

You should not get this error.

Call Intermec Technical Support.

Creattemp() ERROR: Too many open files.

Your system is out of file handles.

Modify the CONFIG.SYS file on the Installation Utility disk and increase the FILES= parameter.

DEVICE ERROR! (hardware error on a non-disk device.)

•

Serial link error.

•

Restart the Installation Utility.

•

System error, bad COM port or cable.

•

Replace the bad port or cable.

Domain must be a number between 0 and 15.

You did not select a valid domain.

Select a number between 0 and 15 for the domain. The domain must be the same for all devices in the subnetwork.

Error, IP address is a special case IP address.

You have entered a special case IP address (host, broadcast, or loopback address) on the Installation Options screen.

To enter a special case IP address, leave the IP address field blank on the Installation Options screen. Use the Shell Out option to edit the NET.CFG file and enter the special case address in the NET.CFG.

4-4