Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 12

JANUS 2.4 GHz Installation Utility (4MB) User's Manual, pages 31 to 40

Pages 31 to 40 of 119

The original document is the PDF (556 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec JG2020 and Intermec JG2050

Page 31

Preparing to Run the Installation Utility

2

Radio Parameters Screen Field Descriptions Field

Description

Station Type

You can choose master, alternate master, or station as your station type. The default is station. Alternate masters act either as a master or a station. If an alternate master unit is unable to locate any other master within range, it acts as a master. If a master station is already present, then the alternate master acts as a station.

Master Name

Masters and alternate masters. This optional parameter can be up to 11 alphanumeric characters. Each master name specifies a name that simplifies the identification of each master in your network.

Channel

Masters and alternate masters. Enter the channel (1 to 15) through which the master communicates with its stations. For each domain (subnetwork), select a different channel for each master to communicate with all the stations. The channels are 1 to 15. The default is 1. Each channel separates communications for each subnetwork to allow for a higher data rate transmission capability in the same airspace. Each channel provides 1.6 Mbps, for a maximum total bandwidth of 24 Mbps in a particular area.

Subchannel

Masters only. Enter the subchannel (1 to 15) through which the master communicates with its stations. If you have more than 15 masters in the same area, change the subchannel to a different value to separate the various networks. The subchannels are designated 1 to 15. The default is 1.

Domain

Enter the domain (0 to 15) of the subnetwork. If you want stations to be able to roam between masters in a subnetwork, all station types (master, alternate master, station) require the same domain number. The domain is a number from 0 to 15. The default is 0.

Inactivity Minutes

This parameter, with inactivity seconds, defines the length of time that the device stays on when there is no activity. If this time is exceeded, the radio is placed in a Sleep mode. The maximum amount of inactivity time you can set is 21 minutes, 15 seconds. The default and recommended setting is 0.

2-11

Page 32

JANUS 2.4 GHz Installation Utility User’s Manual (4MB)

Field

Description

Inactivity Seconds

This parameter, with inactivity minutes, defines the length of time that the device stays on when there is no activity. If this time is exceeded, the radio is placed in a Sleep mode. Inactivity seconds can be from 0 to 60, in multiples of 5. The default and recommended setting is 5, which means that the radio will enter the Sleep mode after five seconds of inactivity. If you specify a number of seconds greater than 0, but less than 5, this parameter will automatically jump to 5 seconds.

Wakeup on Broadcast

Choose Yes if you want the radio to wake up and receive a broadcast packet when it is sent through the network. The default is No.

After you JANUS radio enters Sleep mode, it enters a Standby mode where the clock power is lessened to save power. Also, you may want to use the automatic shutoff feature on your JANUS RF device to save power. The automatic shutoff command defines the length of time of inactivity on the JANUS device before it enters Suspend mode.

Shelling Out to DOS When the Installation Utility has uploaded the JANUS images to the host PC, you can shell out to DOS if you need to perform any of these tasks. •

Create a custom JANUS.INI file. If you are installing Novell TNVTxxx or NetWare Client for DOS on your JANUS device you need to create this file. For help, see “Creating a JANUS.INI File” in Appendix B.

•

Modify the J24TE.INI file. If you are installing Intermec terminal emulation on your JANUS device you may want to customize this file to permanently change your JANUS operating environment. For help, see “Customizing the J24TE.INI File” in Appendix B.

•

Add your data collection application.

Note: Intermec recommends that you do not run any other applications, such as Windows, from the DOS command line. Only use the DOS file editor or DOS commands to edit the files or directories. If the files you want to copy to drive C exceed the capacity of the drive, the following messages appear when you type exit at the DOS prompt.

2-12

Page 33

Preparing to Run the Installation Utility

2

Do you want to shell out to DOS and reduce number of files? (Y/N)

To correct this problem, choose Y to shell out to DOS. Delete files from \IM_FLASH\DRIVEC. This message will keep repeating each time you type exit until you create enough free disk space for the drive C image.

Configuring Multiple JANUS RF Devices After the Installation Utility has configured your first JANUS device, a message box asks you if you want to do another installation. At this point, you can: •

Configure another JANUS RF device.

•

Save your drive images so that you can configure another JANUS device later.

Intermec recommends that you test the device before you exit the Installation Utility or before you configure other JANUS RF devices. If the device is not configured correctly, proceed with another installation and change the parameter that is causing the failure (for example, incorrect domain, IP address, etc.). If you choose to configure another JANUS device, a message box asks you to confirm the type of installation you want to perform. If you choose Y, the Installation Options screen appears again. You are not be able to change the options in the first four fields. During the same installation, each device must be configured for the same network software, version, path, and flash image drive. Depending on your network software, you can change the following parameters:

2-13

Page 34

JANUS 2.4 GHz Installation Utility User’s Manual (4MB)

If you are installing

You can change

NetWare Client for DOS

Novell User Name Novell Server Name Bindery Emulation Preferred Tree Name Context For an explanation of these parameters, refer to “NetWare Client for DOS Parameters” earlier in this chapter.

LAN WorkPlace for DOS • • • •

Intermec TNVTxxx Emulation Intermec 3270 Emulation Intermec 5250 Emulation Novell TNVTxxx Emulation

FTP PC/TCP

Station IP Address Unix User Name Subnet Mask Default Router Host IP Address or Host Name For an explanation of these parameters, refer to “LAN WorkPlace for DOS Parameters” earlier in this chapter. Station IP Address Subnet Mask Default Router

If you press N, you can change the type of terminal emulation software that you want to install before going to the Installation Options screen. If you change the terminal emulation, you will need to insert the TE Applications disk so the Installation Utility can get the necessary terminal emulation software.

2-14

Page 35

3 Running the Installation Utility

Page 36

This page is a scan with no text; see it in the PDF.

Page 37

Running the Installation Utility

3

This chapter explains how to use the Installation Utility to configure one or more JANUS RF devices. For more detailed information about these procedures, see Chapter 2, “Preparing to Run the Installation Utility.”

Starting the Installation Utility •

At the DOS prompt of your host PC, type this command and press Enter. a:install

Configuring the First JANUS RF Device For help understanding any of the processes or parameters, see Chapter 2, “Preparing to Run the Installation Utility.”

Choosing the Configuration Parameters 1. The Choose a Device to Configure screen is the first to appear. Use the arrow key to select the type of JANUS RF device that is connected to your host PC and press Enter.

2. The Select a Network/Protocol screen appears. Use the arrow key to select the type of software that you want to install on the device and press Enter.

3-3

Page 38

JANUS 2.4 GHz Installation Utility User’s Manual (4MB)

3. The Choose a Character Set screen appears for TNVT and Netware Client installations only. Use the arrow key to select the appropriate character set and press Enter.

4. A message box appears with your selections. Choose Y if the selections are correct and you want to proceed to Step 5. Or, choose N to return to the first configuration screen. Go to Step 1.

5. The Installation Options screen appears. •

If you specified Intermec terminal emulation or Novell TNVTxxx on the Select Network/Protocol screen, the Novell Product to Install is LAN WorkPlace for DOS.

•

If you specified FTP Customer Application on the Select Network/Protocol screen, the product to install is FTP PC/TCP for DOS.

A message box appears when you tab out of the Drive that will be used to build new flash images field on the Installation Options screen, if there is an existing C:IM_FLASH subdirectory. OK to delete subdirectory C:\IM_FLASH (Y/N)? Y

3-4

Page 39

Running the Installation Utility

3

If you choose N, a message box appears asking if you want to copy the files to another directory. Choose Y to shell out to DOS and use DOS command to copy the files to another directory. Or, choose N. Shell out to DOS and copy files to another directory? (Y/N)

If you choose N, a message box appears informing you that the files have been saved and then the Installation Utility will start over. Save the files in C:\IM_FLASH, then re-run the Install Program.

Enter the information in the Installation Options screen.

3-5

Page 40

JANUS 2.4 GHz Installation Utility User’s Manual (4MB)

For help with LAN WorkPlace for DOS, see “LAN WorkPlace for DOS Parameters” in Chapter 2. For help with NetWare Client for DOS, see “NetWare Client for DOS Parameters” in Chapter 2. For help with FTP PC/TCP for DOS, see “FTP PC/TCP for DOS Parameters” in Chapter 2.

3-6