2 Preparing to Run the Installation Utility
Page 22
Page 23
Preparing to Run the Installation Utility
2
This chapter tells you what information you need to obtain before running the Installation Utility. It also helps you understand the parameters.
Why Read This Chapter? Running the Installation Utility, it can take up to 10 minutes to configure your first JANUS RF device depending on the baud rate you use for data transmission. Once you start running the Installation Utility, you must either complete the entire procedure to configure the first JANUS RF device or abandon the procedure and start over again. You cannot stop and then restart the process in the middle. Completing the installation tasks will be easier if you understand this chapter and have the correct configuration parameter information before you start.
Setting Up the Host PC You can use any type of PC as your host PC as long as it meets the minimum system requirements listed in “Host PC Requirements” in Chapter 1.
Creating a HOSTS File If you are using Intermec or Novell terminal emulation (LAN WorkPlace for DOS), you can create a HOSTS file in the directory \NET\TCP on the host PC. The Installation Utility will download the HOSTS file to the JANUS RF device. The HOSTS file is a hostname database that contains a list of the remote hosts that you can reach. Each line contains the host IP address and its aliases. For example: 192.9.175.274 host1 192.9.175.13 sunhost1
This ASCII text file must be less than 50K or it will not fit on the JANUS device. 50K is enough space to support a large network, most data collection networks will require a much smaller file. If you choose not to create a HOSTS file, this non-fatal diagnostic message appears during the installation. Warning, HOSTS Too Large or Not Found, Continue?
Refer to your network documentation for help on creating and interpreting HOSTS files.
2-3
Page 24
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
Understanding Configuration Parameters Use the following configuration parameter definitions when you fill in fields on the terminal selection, character set, network, and radio parameters screens.
Terminal Selection Screen
Use the Choose a Device to Configure screen to specify the type of JANUS device that you want to configure.
Network/Protocol Selection Screen
If your JANUS device is going to emulate a terminal, use the Select a Network/Protocol screen to specify the terminal type. The Installation Utility will load the appropriate terminal emulation application. Refer to the JANUS 2.4 GHz Terminal Emulation Quick Reference Guide for information about using Intermec terminal emulation software. Note: If you configure your JANUS device to run terminal emulation software, a terminal emulation session will start after you complete the installation and reboot the device. If you do not want the terminal session to start, you need to modify your APP.BAT file or you can add a REM before the statement in the AUTOEXEC.BAT file that calls the APP.BAT file. Intermec TNVTxxx Emulation This Intermec software allows your device to emulate a VT120/220/320 or ANSI terminal using a telnet session.
2-4
Page 25
Preparing to Run the Installation Utility
2
Intermec 3270 or 5250 Emulation This Intermec software allows your device to emulate an IBM 3270 or 5250 terminal using a telnet session. Note: The UDP+ option is for communication with the Model 200 Controller. Novell TNVTxxx Emulation Select this option to configure your JANUS device to emulate a VT120/220/320 or ANSI terminal using a telnet session. You may also need to load an application when running this emulation. NetWare Client for DOS This Novell software allows your device to run your applications using SPX/IPX protocol. FTP PC/TCP Stack This TCP/IP stack allows your JANUS device to run applications using the PC/TCP stack from FTP Corporation. Note: To install the FTP PC/TCP stack you will need to purchase the FTP PC/TCP Stack Disk (P/N 067791). See your Intermec sales representative to order the FTP disk.
Character Set Screen
The Choose a Character Set selection screen configures your JANUS RF device for the selected character set. The Installation Utility supports international character sets for France, Germany, Italy, and Spain. The default BIOS keyboard driver supports the U.S. character set. An international character set allows DOS to display date and time prompts, currency symbols, date separators, time separators, and decimal separators in the standard format of the chosen country. The international character set drivers do not translate DOS message text. If you select a non-U.S. character set, these actions are performed when the CONFIG.SYS file is processed: •
The COUNTRY configuration command is executed, which customizes country-dependent information (such as date and time formats, currency symbols, collating sequences, etc.) for a particular country.
•
The DISPLAY.SYS device driver is loaded to support code page (character set) switching for the console device (LCD).
2-5
Page 26
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
If you select a non-U.S. character set, these actions are performed when the AUTOEXEC.BAT file is processed: •
The appropriate code page is selected.
•
The appropriate code page is prepared.
•
The KEYB.COM program is loaded to replace the current keyboard driver.
Switching Between Keypads Use the following commands to switch between keypad configurations on your JANUS RF device.
> < G to switch to the U.S. keypad. • > < H to switch to the keypad driver installed for the country you • selected.
Conventional Memory Required Configuring for international character sets requires an additional 17K to 35K of conventional memory on your JANUS device.
About the Network Parameters Use the Installation Options screens to enter the network parameters for FTP PC/TCP for DOS, NetWare Client for DOS or LAN WorkPlace for DOS and the radio parameters. At this point, the utility checks to make sure that you have at least 14MB of hard disk space available on your host PC. The Installation Options screen that appears depends on which terminal software option you chose in the Terminal Selection screen.
2-6
•
LAN WorkPlace for DOS. This screen appears if you choose to load software that uses TCP/IP (Intermec TNVTxxx, 3270 or 5250, or Novell TNVTxxx).
•
NetWare Client for DOS. This screen appears if you choose to load software that uses SPX/IPX (NetWare Client).
•
FTP PC/TCP for DOS. This screen appears if you choose to load software that uses PC/TCP for DOS.
Page 27
Preparing to Run the Installation Utility
2
LAN WorkPlace for DOS Parameters
Field
Description
Version
Choose the version of LAN WorkPlace for DOS you are installing (4.2, 5.0, or provided).
Path to LAN WorkPlace Installation
Enter the location (drive:\pathname) of LAN WorkPlace for DOS on your host PC (for version 4.2 or 5.0).
Drive that will be used to build new flash images
Enter the hard drive (or partition) on your host PC that you want to use as a scratch drive to build the JANUS drive images. 14MB is required.
Station IP Address
Enter the JANUS device IP address.
Unix User Name
Enter a valid user name for the UNIX environment.
Subnet Mask
The Installation Utility enters the first part of the subnet mask based on the Station IP address. Enter the last part of the subnet mask.
Default Router
The Installation Utility enters the first part of the default router address based on the Station IP address. Enter the last part of the default router address.
Host IP Address or Host Name.
The Installation Utility enters the first part of the host IP address based on the Station IP address. Enter the last part of the host IP address or enter a host name.
0200 Controller IP Address
(UDP Plus only) Enter the IP address of the Model 200 Controller that you plan to communicate with.
2-7
Page 28
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
NetWare Client for DOS Parameters
2-8
Field
Description
Version
(3.12, 4.x) Choose the version of NetWare Client for DOS you are installing.
Path to NetWare Client Installation
Enter the location (drive:\pathname) of NetWare Client for DOS files on your host PC.
Drive that will be used to build new flash images
Enter the hard drive (or partition) on your host PC that you want to use as a scratch drive to build the JANUS drive images. It must have at least 14MB free.
Novell User Name
(Optional) Enter the user’s login name that will be used to log in to the network.
Novell Server Name
(Optional) Enter the server name to which the JANUS device will connect.
Bindery Emulation
(Optional) Choose Yes to enable bindery emulation.
Preferred Tree
(v4.x only) Enter the preferred tree.
Name Context
See your Novell NetWare Client documentation.
Page 29
Preparing to Run the Installation Utility
2
FTP PC/TCP for DOS Parameters
Field
Description
Path to Network Installation
Enter the location (drive:\pathname) of FTP PC/TCP files on your host PC.
Temporary drive for flash images
Enter the hard drive (or partition) on your host PC that you want to use as a scratch drive to build the JANUS drive images. It must have at least 14MB free.
Install Novell compatibility shim
(Optional) Installing the Novell compatibility shim allows you to run applications written for the Novell stack to run on top of the FTP stack.
Station IP Address
Enter the JANUS device IP address.
Subnet Mask
The Installation Utility enters the first part of the subnet mask based on the Station IP address. Enter the last part of the subnet mask.
Default Router
The Installation Utility enters the first part of the default router address based on the Station IP address. Enter the last part of the default router address.
2-9
Page 30
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
About the Radio Parameters Use the Radio Parameters screen to configure the parameters that are required for your JANUS RF device to communicate with access points. All devices in the same subnetwork must have the same domain and the same security ID. Security IDs are optional. Use different domains on devices if they are in the same area and you want the devices to communicate to different hosts. Each domain (subnetwork), must have one acting master to coordinate communications from the various stations. For most network operating systems, the access point is the master. If the master unit is turned off or is out of range, then one of the other access points configured as an alternate master becomes the master. For most network operating systems, the JANUS RF devices are stations. If the inactivity settings are exceeded and your radio is placed into Sleep mode, you can wake up the radio by either answering yes to the Wake Up on Broadcast parameter, or you can physically suspend and resume the JANUS RF device (press the button twice) when the device is running.
L
Note: Intermec recommends that you keep the default settings for Inactivity Minutes and Inactivity Seconds. The default setting ensures that you will receive optimum battery life on JANUS devices with removable batteries.
2-10