Page 51
Troubleshooting
4
Error Message
Problem
Solution
ERROR:JG20xx selected, JG20xx platform detected
You have specified a JANUS model number that is different from the device that you are configuring. xx is the 10, 20, or 50 as appropriate.
The JANUS model number you specify during the installation must match the device that is connected to the host PC. Retry running the Installation Utility and specify the correct model number.
ERROR:JG20xx selected, J2010 w/a PCMCIA back detected
You have specified a JANUS model number that is different from the device that you are configuring. xx is the 10, 20, or 50 as appropriate.
The JANUS model number you specify during the installation must match the device that is connected to the host PC. Retry running the Installation Utility and specify the correct model number.
Error Loading RL2OEM.COM.
If you get this message when the JANUS device boots, it indicates that the radio failed to initialize because of a hardware problem.
Contact Intermec Technical Support.
Error, This IP address is the same as the 0200 Controller IP address.
You are using a duplicate IP address.
Verify that you are using the correct IP address.
Error, This IP address is the same as the Host IP address.
You are using a duplicate IP address.
Verify that you are using the correct IP address.
Error, This IP address is the same as the Router IP address.
You are using a duplicate IP address.
Verify that you are using the correct IP address.
Error, This IP address is the same as the Station IP address.
You are using a duplicate IP address.
Verify that you are using the correct IP address.
External AC Power was not Plugged In, Try Again?
External AC power supply was not plugged into the JANUS device.
1.
Make sure you have an external AC power supply plugged into the JANUS device.
2.
Choose Yes to try programming flash memory again.
Failure Copying C:\NET\TCP\PROTOCOL to D:\NET\TCP D:\NET\TCP\PROTOCOL successfully created
A file required for the installation was missing and the Installation Utility created the file.
Acknowledge the message by pressing any key and continue with the installation.
Flash Loader Aborted by User, Try Again?
You pressed Ctrl-Break to interrupt the Flash Loader program.
Choose Yes if you want to restart the JANUS 2000 Flash Loader program.
Flash Loader Reported a Communication Failure Error, Try Again?
Serial link failed.
Choose No if you do not want to complete the installation. •
Choose Yes to try programming flash memory again.
•
Restart the Installation Utility.
4-5
Page 52
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
Error Message
Problem
Solution
Flash Loader Reported a General Failure Error, Try Again?
General failure.
•
Choose Yes to try programming flash memory again.
•
Restart the Installation Utility.
Host must be running DOS 5.0 or above.
You are not running DOS 5.0 or above on your host PC.
•
Install DOS 5.0 or above on your host PC.
•
Use a different host PC that is running DOS 5.0 or above.
INSTALL.EXE Error: Command line parameter error.
Software error.
Contact your Intermec representative.
INSTALL.EXE Error: File is Wrong Size.
Software error.
Contact your Intermec representative.
INSTALL.EXE Error: File not Found.
Software error.
Contact your Intermec representative.
INSTALL.EXE Error: Unable to Open File.
Software error.
Contact your Intermec representative.
Installation Disk MUST be in Drive A.
•
You are trying to run PCSETUP from drive B.
•
The Installation Utility disk is no longer in drive A.
Place the Installation Utility disk in drive A of your host PC and type a:\install.
Insufficient Memory.
Invalid Port, LOAD Not Selected, or Cable Unplugged, Try Again?
System error.
•
You may have selected the wrong serial port on your host PC (COM1, COM2, COM3, or COM4).
•
You may not have selected LOAD and pressed e on your JANUS device.
•
Manufacturing ID not Received, Try Again?
4-6
You may not have the host PC and the JANUS device connected with a null modem cable.
Manufacturing ID not received.
•
Restart the Installation Utility.
•
Perform diagnostics on the host PC.
•
Make sure that you selected the correct serial port on your host PC where your JANUS device is connected. Choose Yes to try again.
•
Make sure you selected LOAD and pressed on your JANUS device. Choose Yes to try again.
•
Connect a null modem cable from your host PC to the serial port on the JANUS. Choose Yes to try again.
@
Answer Yes to try programming flash memory again.
Page 53
Troubleshooting
4
Error Message
Problem
Solution
Need at least rK of Extended Memory, only have iK.
•
You do not have enough extended memory on your host PC.
Make sure that your host PC has at least 4MB of RAM.
•
You are running the Installation Utility on a host PC that does not follow the established CMOS standards.
r = Total kilobytes of extended memory required i = Total kilobytes of extended memory installed
You must have at least 14MB of free space on your scratch drive.
•
Make sure that you specify a valid physical hard drive.
•
Remove or move files from the drive you are using for the scratch drive until you have 14MB of free space.
Path must include a drive specifier.
You did not type a drive letter when you specified the pathname.
Add a drive letter, colon, and back slash to the pathname. For example: C:\
Subchannel must be a number between 1 and 15.
You did not select a valid subchannel.
Select a number between 1 and 15 for the subchannel.
Unable to Create New JANUS Drive C Image!
System error. You may have copied too many files to the \IM_FLASH\DRIVEC directory.
Restart the Installation Utility.
Unable to Create New JANUS Drive D Image!
System error.
Restart the Installation Utility.
Unable to Find Application Image in Archive File.
Bad companion disk 1.
Make another copy of the Boot Utilities companion disk from the original disk.
Unable to Find Specified Block in 4MEG2_4.INI.
Software error. You may have modified this .INI file.
Contact your Intermec representative.
Unable to Find System Image in Archive File.
Bad boot utilities disk.
Make another copy of the Boot Utilities companion disk from the original disk.
Unable to Find User Image in Archive File.
Bad boot utilities disk.
Make another copy of the Boot Utilities companion disk from the original disk.
Unable to Free Enough Drive D Space.
You have too many files in the NetWare Client or LAN WorkPlace subdirectories.
Review the source subdirectories and eliminate unnecessary files. If the software was installed using Windows support, delete the Windows files and reinstall the software without Windows support.
Only X bytes available on C:, Need Y. X = Total bytes available. C: = Scratch drive specified by user. Y = Total bytes required.
4-7
Page 54
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
Error Message
Problem
Solution
Unable to Update Flash, Try Again?
Unknown flash loader error.
Contact your Intermec representative.
Unable to Verify Installation Path.
You specified an installation path that does not exist.
Enter the name of an installation path that does exist.
v1.31 detected, must be v4.00 v4.99
The JANUS software you are using is an older version and can’t be installed.
Make sure you follow the procedure to download the default drive images from the Installation Utility disk to the JANUS device.
VPP Programming Voltage not Present, Try Again?
AC adapter bad, not plugged in, or loose.
•
Connect an external AC power supply to the JANUS device (or make sure it is pushed in all the way).
•
Choose Yes to try programming the JANUS flash memory again.
WARNING, current IP address matches previous IP address. Do you want to change the current IP address?
On additional installations, the Installation Utility provides this warning message if you use a duplicate IP address
Verify you are using the correct IP address and continue. You have the option of changing the IP address at this time.
Warning, HOSTS Too Large or Not Found, Continue?
Your HOSTS file must be less than 50K.
•
Ignore this message if you do not have a HOSTS file and answer Yes to continue.
•
Reduce the number of alias lists in your HOSTS file and answer Yes to continue.
Drive A Error Messages These disk drive error messages refer to the current drive being accessed. This table lists the error messages in alphabetical order. If an error message appears on your screen, locate it in the table and use the problem and solution columns to help you correct the error. Error Message
Problem
Solution
Error: data error (CRC) on the A: Drive.
DOS was unable to read or write the data correctly.
•
Retry the operation.
•
Replace the disk.
This error is usually caused by a defective area on the disk.
•
Check your disk using the CHKDSK command.
4-8
Page 55
Troubleshooting
4
Error Message
Problem
Solution
Error: general failure on the A: Drive.
•
The disk is incompatible with your host PC drive.
•
•
The drive door is open or the disk is not in the drive.
Make sure that you are not using a high density disk in a low density drive.
•
•
Disk is not properly formatted.
Properly insert the disk and close the drive door.
•
Reformat the disk.
•
Replace the disk.
Error: invalid disk change on the A: Drive.
You changed disks before all the files were closed.
Reinsert the original disk so the files can be closed.
Error: read fault on the A: Drive.
•
Drive media error.
•
DOS was unable to read data from the disk.
• Make sure that the disk is properly seated in the drive and retry the operation. • Replace the disk.
Error: sector not found on the A: Drive.
Error: seek error on the A: Drive.
•
Drive media error.
• Retry the operation.
•
DOS could not find the disk sector containing the requested data.
• Make a copy of the bad disk and reformat the bad disk.
The disk drive could not find the specified disk cylinder.
• Make another copy of the Installation Utility disk from the original Installation Utility disk. • Retry the operation. • Replace the disk. • Perform diagnostics to determine the type of failure.
Error: unknown media type on the A: Drive.
Drive media error.
Installation Disk w/file 4MEG2_4.INI MUST be in Drive A.
The Installation Utility cannot find the 4MEG2_4.INI file.
• Replace the disk. • Reformat the disk. • Make sure that you inserted the Installation Utility disk in drive A. • Make sure the Installation Utility disk in drive A contains the 4MEG2_4.INI file. If you cannot find the file, contact Intermec Technical Support.
4-9
Page 56
Page 57
A Deleted, Modified, and New Files
Page 58
Page 59
Deleted, Modified, and New Files
A
This appendix lists the files that the Installation Utility deletes from the JANUS devices. It provides printouts of the modified CONFIG.SYS and AUTOEXEC.BAT files and the new NET.CFG, NET.BAT, APP.BAT, GO.BAT, UNNET.BAT, PCTCP.INI, and UDPPLUS.INI files. It also lists the minimum required files for a LAN WorkPlace for DOS installation.
Deleted Files This section lists the files that are deleted from the JANUS drives C and D. If you use the shell out feature, you can restore selected files that the Installation Utility removes. You can also add the application that you will be running to drive C or D. Use DOS commands to choose which files you want to keep and which ones you want to delete.
Files Removed From Drive C The Installation Utility removes the following files from drive C on the JANUS device. These files are stored in \IM_FLASH\DRIVECX. CARDINFO.EXE COMMAND.COM INITENV.EXE JANUS.MRF MCFORMAT.EXE
Files Removed From Drive D To fit the Intermec or Novell software on the JANUS device, the Installation Utility needs at least 700K of free space. The Installation Utility removes these files from drive D on the JANUS device. These files are stored in the \IM_FLASH\DRIVEDX directory. ANSI.SYS
LABEL.EXE
ATTRIB.EXE
PHIMEC.EXE
DEBUG.EXE
PHPCSTD.EXE
EDLIN.EXE
RFPH.EXE
FC.EXE
SETVER.EXE
INTERSVR.EXE
SORT.EXE
IRL.BAT
SUBST.EXE
IRL001.DAT
UNDELETE.EXE
IRLDESK.EXE
A-3
Page 60
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
These files are conditionally deleted from drive D if additional space is required. Files are deleted in the order listed. ANSI.SYS PHPCSTD.EXE PHIMEC.EXE INTERSVR.EXE CHKDSK.EXE FORMAT.COM MEM.EXE MORE.COM XCOPY.EXE DOSKEY.EXE
Modified CONFIG.SYS File The Installation Utility modifies the CONFIG.SYS file that was on the JANUS device. The following are examples of the new files.
JG2010 CONFIG.SYS REM * REM * FILENAME: CONFIG.SYS REM * REM * PROD ID: J2010 REM * REM * VERSION: 4.04H REM * REM * SETUP BOOT MENU ITEMS [MENU] MENUITEM=SRAM, SRAM PCCARD MENUITEM=ATA, ATA PCCARD MENUITEM=FLASH, FLASH PCCARD MENUITEM=IO, I/O PCCARD MENUITEM=NO, NO PCCARD MENUCOLOR=15,0 MENUDEFAULT=SRAM, 20 [COMMON] REM * COMMON TO ALL CONFIGURATIONS REM * SET ENVIRONMENT SIZE SHELL=COMMAND.COM /E:2000 /P
A-4