The text of a manual · part 15 of 46
DCS 300 User's Manual, pages 141 to 150
Pages 141 to 150 of 460
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec DCS-300
Page 141
Connecting to the Intermec RF Network
6
Editing the WTP Network When you edit the WTP network, the WTP Parameters dialog box looks slightly different than when you added the network. Rename RF Hosts This button lets you rename the RF host. Enter the new name in the field and then choose Rename. Note that each WTP device is configured with the RF host instance that it is using to communicate with the DCS 300. If you change the RF host name, you must reconfigure each device with the new name. To edit the WTP network •
From the Connection Point List dialog box, choose WTP and then choose Edit. The WTP Parameters dialog box appears.
6-39
Page 142
DCS 300 User’s Manual
Enabling the WTP Devices You do not need to enable each WTP device that you want to communicate with the DCS 300. The device list contains the logical names of all 254 WTP devices. The MAC address of the device only appears when a device connects with the server. You can edit each terminal to change its logical name, device type, MAC address, number of terminal sessions, transaction IDs, and delivery responses. Your server is licensed to communicate with a fixed number of devices (1-8, 1-24, 1-64, 1-254). As each device sends messages to the server, the server logs its logical name. When the server logs the maximum number of logical names that your terminal license allows, it will not accept messages from any new logical names. When you stop data collection on the server, the terminal license count number is reset. If you need to purchase an upgrade to your terminal license, contact your local Intermec representative. To identify the WTP devices 1. From the main menu, choose the type of communication you are using to connect the server to the host. 2. Choose Downline Network. Two buttons, Connection Points and Downline Devices, appear. 3. Choose Downline Devices. The Device List dialog box appears.
6-40
Page 143
Connecting to the Intermec RF Network
6
Device List Dialog Box
4. In the Connection field, click the down arrow on the right side of the field. A list of the connection points that you have configured appears. Select WTP. 5. Select a terminal whose individual parameters you want to edit and choose Edit Device. Follow the next procedure, “Editing a WTP Device.” 6. Choose OK to save your changes and return to the main menu.
6-41
Page 144
DCS 300 User’s Manual
Editing a WTP Device •
From the Device List dialog box, choose Edit Device. The Device Parameters dialog box appears. Note: If you are using terminal emulation, do not configure transaction IDs or delivery responses.
6-42
Page 145
Connecting to the Intermec RF Network
Field
Description
Value
Default
Logical name
The logical name of the device. This name is created from the base logical name plus a 3digit number.
1 to 16 alphanumeric characters
HOST000
Able to receive data
This check box determines if this device can receive data from the network.
Check, Clear
Check
Device type
This list box contains all the current Intermec devices supported.
Predefined list
Undefined
Auto-insert from device
This field provides a transaction ID for this device if it cannot put a transaction ID in its transactions.
Predefined list
None
6
Note: All transactions from this terminal are routed using this transaction ID. To be routed to device
This field contains a transaction ID that will always be routed to this device.
Predefined list
None
Interactive response (Optional)
The message that is sent to the source of the transaction if the transaction is delivered successfully to this device.
1 to 39 characters
None
Hot standby (Optional)
The message that is sent to the source of the transaction if the transaction for this device is written to a Hot Standby file.
1 to 40 characters
None
Saving Your Run-Time Configuration When you finish configuring your downline network, you should save your changes. To save your run-time configuration •
From the main menu sidebar buttons, choose Save Configuration.
6-43
Page 146
DCS 300 User’s Manual
6-44
Page 147
7 Connecting to the 9180 and the Intermec CrossBar Network
Page 148
DCS 300 User’s Manual
Page 149
Connecting to the 9180 and the Intermec CrossBar Network
7
This chapter describes how to configure the DCS 300 to communicate with the 9180 Network Controller, other controllers in Intermec’s CrossBar network, and the CrossBar devices.
Chapter Checklist Done?
‰ ‰ ‰ ‰ ‰ ‰
Task
Page
Install all your Intermec controllers.
None
Identify all the controllers on the DCS 300.
7-4
Configure each controller connected to the DCS 300.
7-6
Set the time parameters for each controller.
7-15
Identify all the CrossBar devices connected to controllers.
7-20
Edit the CrossBar devices.
7-22
Note: In order for the 9181 Base Radio Units (BRUs) to communicate with a 9180 Network Controller that is connected to the DCS 300, you need to configure these BRUs using the 9180 configuration menu. Refer to your 9180 user’s manual. If you already understand these sections and have already performed these tasks, connect the DCS 300 to your Intermec RF network or host environment as described in these chapters: •
Chapter 6, “Connecting to the Intermec RF Network”
•
Chapter 8, “Using Terminal Emulation”
•
Chapter 9, “Using Peer-to-Peer Applications”
•
Chapter 10, “Using Terminal Sessions”
7-3
Page 150
DCS 300 User’s Manual
Configuring an Intermec Controller An Intermec controller is a 9180 Network Controller, 9161 Port Concentrator, or a 9154 Multi-Drop Line Controller that is connected to the DCS 300 through a serial port. The following illustration is an example of a DCS 300 connected to a 9180 and a CrossBar network.
Example: The DCS 300 Connected to a 9180 and CrossBar Network Host
DCS 300
RS-232
RS-232
9154
9180
JR2020 JR2020
9445 9560
9181
9181
0300U.017
3400
7-4