Page 131

Connecting to the Intermec RF Network

6

Device List Dialog Box

4. In the Connection field, click the down arrow on the right side of the field. A list of the connection points that you have configured appears. Select UDP Plus. 5. To enable all 254 devices, choose Enable All. Or, to enable specific terminals, select the terminal you want to enable and make sure there is a check in the Enabled check box. Note: Each terminal must use DNS or have a valid IP v4 address before you can enable it. 6. To disable all 254 terminals, choose Disable All. Or, to disable specific terminals, select the terminal you want to disable and make sure there is no check in the Enabled check box. 7. Select a terminal whose individual parameters you want to edit and choose Edit Device. Follow the next procedure, “Editing a UDP Plus Device.” 8. Choose OK to save your changes and return to the main menu.

6-29

Page 132

DCS 300 User’s Manual

Editing a UDP Plus Device This dialog box lets you edit many parameters for your UDP Plus terminal. If you need to edit or resolve the IP address of the terminal, see “Determining a UDP Plus Device’s IP Address” or “Editing a UDP Plus Device’s IP Address” later in this chapter. To edit a UDP Plus device •

From the Device List dialog box, choose Edit Device. The Device Parameters dialog box appears. Note: If you are using terminal emulation, do not configure transaction IDs or delivery responses.

6-30

Page 133

Connecting to the Intermec RF Network

Field

Description

Value

Default

Logical name

The logical name of the terminal. This name is created from the base logical name plus a 3-digit number.

1 to 16 alphanumeric characters

UDPPXXX

Able to receive data

This check box determines if this terminal can receive data from the network.

Check, Clear

Check

Device type

This list box contains all the current Intermec terminals supported.

Predefined list

2400

Auto-insert from device

This field provides a transaction ID for this terminal if it cannot put a transaction ID in its transactions.

Predefined list

None

6

Note: All transactions from this terminal are routed using this transaction ID. To be routed to device

This field contains a transaction ID that will always be routed to this terminal.

Predefined list

None

Interactive response (Optional)

The message that is sent to the source of the transaction if the transaction is delivered successfully to this terminal.

1 to 39 characters

None

Hot standby (Optional)

The message that is sent to the source of the transaction if the transaction for this terminal is written to a Hot Standby file.

1 to 40 characters

None

6-31

Page 134

DCS 300 User’s Manual

Determining a UDP Plus Device’s IP Address If you are using a DNS server and you want to know the IP address of a terminal, then from the Device Parameters dialog box, choose Addressing. The Device Address dialog box appears.

To determine a terminal’s IP address 1. (Optional) In the Domain field, enter the specific domain that contains the terminal. 2. Choose Resolve to look up the terminal’s IP address on the DNS server using the logical name. If you did not enter a domain, the server searches the list of domains that are configured in the DNS Configuration dialog box.

Editing a UDP Plus Device’s IP Address If you are not using a DNS server and you want to edit the IP address of a terminal, from the Device Parameters dialog box, choose Addressing. The Device Address dialog box appears.

To edit a terminal’s IP address 1. Clear the Use DNS check box. 2. In the IP address field, enter a new IP address for the terminal.

6-32

Page 135

6

Connecting to the Intermec RF Network

Connecting the DCS 300 to the WTP Network The DCS 300 supports communications with WTP devices through access points that are connected to the Ethernet or token ring network. Access points act as bridges between the Ethernet or token ring network and WTP network. The illustration below shows an example of the DCS 300 connected to the WTP network.

Example: The DCS 300 Connected to the WTP Network Synthesized UHF

2.4GHz

Host

6500

RT1700 6400

1100

RT5921

1100 RT5980

Access point

Access point DCS 300

Ethernet Access point

6400 RT5960

1100

902 MHz Falcon 0300U.068

6-33

Page 136

DCS 300 User’s Manual

Configuring a WTP Network You must configure a WTP network if you want the DCS 300 to communicate with WTP devices. To configure a WTP network 1. From the main menu, choose the type of communication you are using to connect the server to the host. 2. Choose Downline Network. Two buttons, Connection Points and Downline Devices, appear. 3. Choose Connection Points. The Connection Point List dialog box appears.

4. Choose Add, Edit, or Delete. If you choose Add, the Add a Downline Connection Point dialog box appears.

6-34

Page 137

Connecting to the Intermec RF Network

6

5. Choose WTP and then choose Add. The WTP Parameters dialog box appears. 6. Configure the WTP network. For help, see “Adding a WTP Network” in the next section. 7. Define how the WTP devices will communicate with each of the different types of hosts. For help, see “Auto-Linking to Hosts” later in this chapter. 8. Choose OK. The WTP Devices dialog box appears. For help, see “Setting Up the WTP Devices” later in this chapter. 9. Choose OK. The RF Hosts Created for WTP dialog box appears. For help, see “About the RF Hosts Created for WTP” later in this chapter. 10. Choose OK to close the RF Hosts Created for WTP dialog box and return to the Connection Point List dialog box. 11. Choose Close to return to the main menu. 12. Enable all the WTP devices that you want to communicate with the server. For help, see “Enabling the WTP Devices” later in this chapter.

6-35

Page 138

DCS 300 User’s Manual

Adding a WTP Network You can define a default method for the WTP devices to get a host name when they are communicating with different types of hosts. You can configure the WTP devices to • explicitly link with a specific host. Click the down arrow on the right side of the field and choose a host that you have configured.

• prompt the user to enter a host name. Click the down arrow on the right side of the field and choose <Prompt>.

• not communicate with a host. Click the down arrow on the right side of the field and choose <none>.

To configure a specific device to communicate in a different way to a host, see “Configuring TE Links” in Chapter 8. After you finish adding the WTP network and you choose OK, the WTP Devices dialog box appears. For help, see “Setting Up the WTP Devices” in the next section. To add a WTP network •

6-36

From the Add a Downline Connection Point dialog box, choose WTP and then choose Add. The WTP Parameters dialog box appears.

Page 139

Connecting to the Intermec RF Network

Field

Description

Value

Default

Ethernet card

The Ethernet card that you want to communicate with the WTP network.

Ethernet 1, Ethernet 2,

Ethernet 1

Hot Standby timeout

The number of seconds the server waits to receive an acknowledgment after delivering a transaction to a device.

1 to 9999

40

6

If it does not receive an acknowledgment, the server writes the transactions for the device to a Hot Standby file. The device receives its transactions from the Hot Standby file when it comes back online. RF host prefix

A name for the server that the server uses to generate the host instances to support the WTP network.

4 to 13 alphanumeric characters

HOST

Skip Unit Ready screen on all terminals

Determines if the WTP devices display their initialization information (Unit Ready) on the screen when they connect to the server.

Check, Clear

Clear

5250/3270 clients connect

Determines which emulation type the server will use to communicate with the host when it receives a transaction from the WTP network.

SNA, Telnet

SNA

Note: WTP devices must communicate with the server using Telnet. The server will convert the transaction to the appropriate format for the host type. 3270 SNA

The host that a WTP device connects to if the device is not explicitly linked to a host and it is running a 3270 application.

None, Predefined list, Prompt

<Prompt>

5250 SNA

The host that a WTP device connects to if the device is not explicitly linked to a host and it is running a 5250 application.

None, Predefined list, Prompt

<Prompt>

Telnet

The host that a WTP device connects to if the device is not explicitly linked to a host and it is running a Telnet application.

None, Predefined list, Prompt

<Prompt>

6-37

Page 140

DCS 300 User’s Manual

Setting Up the WTP Devices When you choose OK in the WTP Parameters dialog box, the WTP Devices dialog box appears. This dialog box generates logical names for each device. After you finish configuring the WTP devices and you choose OK, the RF Hosts Created for WTP dialog box appears. For help, see “About the RF Hosts Created for the WTP Network” in the next section.

Field

Description

Value

Default

Base logical name

The base name that the server uses to create a unique logical name for each device. The server appends a sequential 3-digit number to this name for each device.

1 to 13 alphanumeric characters

HOST

About the RF Hosts Created for the WTP Network If you are adding a WTP network, when you choose OK in the WTP Devices dialog box, the RF Hosts Created for WTP dialog box appears. This dialog box shows you the RF host instances that the DCS 300 has created to support your terminal license. If your terminal license is a Level 3 or a Level 4, you must assign each device to the RF host instance that you want it to communicate with. Each RF host instance supports up to 127 terminal sessions.

6-38