The text of a manual · part 14 of 46
DCS 300 User's Manual, pages 131 to 140
Pages 131 to 140 of 460
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec DCS-300
Page 131
Connecting to the Intermec RF Network
6
Device List Dialog Box
4. In the Connection field, click the down arrow on the right side of the field. A list of the connection points that you have configured appears. Select UDP Plus. 5. To enable all 254 devices, choose Enable All. Or, to enable specific terminals, select the terminal you want to enable and make sure there is a check in the Enabled check box. Note: Each terminal must use DNS or have a valid IP v4 address before you can enable it. 6. To disable all 254 terminals, choose Disable All. Or, to disable specific terminals, select the terminal you want to disable and make sure there is no check in the Enabled check box. 7. Select a terminal whose individual parameters you want to edit and choose Edit Device. Follow the next procedure, “Editing a UDP Plus Device.” 8. Choose OK to save your changes and return to the main menu.
6-29
Page 132
DCS 300 User’s Manual
Editing a UDP Plus Device This dialog box lets you edit many parameters for your UDP Plus terminal. If you need to edit or resolve the IP address of the terminal, see “Determining a UDP Plus Device’s IP Address” or “Editing a UDP Plus Device’s IP Address” later in this chapter. To edit a UDP Plus device •
From the Device List dialog box, choose Edit Device. The Device Parameters dialog box appears. Note: If you are using terminal emulation, do not configure transaction IDs or delivery responses.
6-30
Page 133
Connecting to the Intermec RF Network
Field
Description
Value
Default
Logical name
The logical name of the terminal. This name is created from the base logical name plus a 3-digit number.
1 to 16 alphanumeric characters
UDPPXXX
Able to receive data
This check box determines if this terminal can receive data from the network.
Check, Clear
Check
Device type
This list box contains all the current Intermec terminals supported.
Predefined list
2400
Auto-insert from device
This field provides a transaction ID for this terminal if it cannot put a transaction ID in its transactions.
Predefined list
None
6
Note: All transactions from this terminal are routed using this transaction ID. To be routed to device
This field contains a transaction ID that will always be routed to this terminal.
Predefined list
None
Interactive response (Optional)
The message that is sent to the source of the transaction if the transaction is delivered successfully to this terminal.
1 to 39 characters
None
Hot standby (Optional)
The message that is sent to the source of the transaction if the transaction for this terminal is written to a Hot Standby file.
1 to 40 characters
None
6-31
Page 134
DCS 300 User’s Manual
Determining a UDP Plus Device’s IP Address If you are using a DNS server and you want to know the IP address of a terminal, then from the Device Parameters dialog box, choose Addressing. The Device Address dialog box appears.
To determine a terminal’s IP address 1. (Optional) In the Domain field, enter the specific domain that contains the terminal. 2. Choose Resolve to look up the terminal’s IP address on the DNS server using the logical name. If you did not enter a domain, the server searches the list of domains that are configured in the DNS Configuration dialog box.
Editing a UDP Plus Device’s IP Address If you are not using a DNS server and you want to edit the IP address of a terminal, from the Device Parameters dialog box, choose Addressing. The Device Address dialog box appears.
To edit a terminal’s IP address 1. Clear the Use DNS check box. 2. In the IP address field, enter a new IP address for the terminal.
6-32
Page 135
6
Connecting to the Intermec RF Network
Connecting the DCS 300 to the WTP Network The DCS 300 supports communications with WTP devices through access points that are connected to the Ethernet or token ring network. Access points act as bridges between the Ethernet or token ring network and WTP network. The illustration below shows an example of the DCS 300 connected to the WTP network.
Example: The DCS 300 Connected to the WTP Network Synthesized UHF
2.4GHz
Host
6500
RT1700 6400
1100
RT5921
1100 RT5980
Access point
Access point DCS 300
Ethernet Access point
6400 RT5960
1100
902 MHz Falcon 0300U.068
6-33
Page 136
DCS 300 User’s Manual
Configuring a WTP Network You must configure a WTP network if you want the DCS 300 to communicate with WTP devices. To configure a WTP network 1. From the main menu, choose the type of communication you are using to connect the server to the host. 2. Choose Downline Network. Two buttons, Connection Points and Downline Devices, appear. 3. Choose Connection Points. The Connection Point List dialog box appears.
4. Choose Add, Edit, or Delete. If you choose Add, the Add a Downline Connection Point dialog box appears.
6-34
Page 137
Connecting to the Intermec RF Network
6
5. Choose WTP and then choose Add. The WTP Parameters dialog box appears. 6. Configure the WTP network. For help, see “Adding a WTP Network” in the next section. 7. Define how the WTP devices will communicate with each of the different types of hosts. For help, see “Auto-Linking to Hosts” later in this chapter. 8. Choose OK. The WTP Devices dialog box appears. For help, see “Setting Up the WTP Devices” later in this chapter. 9. Choose OK. The RF Hosts Created for WTP dialog box appears. For help, see “About the RF Hosts Created for WTP” later in this chapter. 10. Choose OK to close the RF Hosts Created for WTP dialog box and return to the Connection Point List dialog box. 11. Choose Close to return to the main menu. 12. Enable all the WTP devices that you want to communicate with the server. For help, see “Enabling the WTP Devices” later in this chapter.
6-35
Page 138
DCS 300 User’s Manual
Adding a WTP Network You can define a default method for the WTP devices to get a host name when they are communicating with different types of hosts. You can configure the WTP devices to • explicitly link with a specific host. Click the down arrow on the right side of the field and choose a host that you have configured.
• prompt the user to enter a host name. Click the down arrow on the right side of the field and choose <Prompt>.
• not communicate with a host. Click the down arrow on the right side of the field and choose <none>.
To configure a specific device to communicate in a different way to a host, see “Configuring TE Links” in Chapter 8. After you finish adding the WTP network and you choose OK, the WTP Devices dialog box appears. For help, see “Setting Up the WTP Devices” in the next section. To add a WTP network •
6-36
From the Add a Downline Connection Point dialog box, choose WTP and then choose Add. The WTP Parameters dialog box appears.
Page 139
Connecting to the Intermec RF Network
Field
Description
Value
Default
Ethernet card
The Ethernet card that you want to communicate with the WTP network.
Ethernet 1, Ethernet 2,
Ethernet 1
Hot Standby timeout
The number of seconds the server waits to receive an acknowledgment after delivering a transaction to a device.
1 to 9999
40
6
If it does not receive an acknowledgment, the server writes the transactions for the device to a Hot Standby file. The device receives its transactions from the Hot Standby file when it comes back online. RF host prefix
A name for the server that the server uses to generate the host instances to support the WTP network.
4 to 13 alphanumeric characters
HOST
Skip Unit Ready screen on all terminals
Determines if the WTP devices display their initialization information (Unit Ready) on the screen when they connect to the server.
Check, Clear
Clear
5250/3270 clients connect
Determines which emulation type the server will use to communicate with the host when it receives a transaction from the WTP network.
SNA, Telnet
SNA
Note: WTP devices must communicate with the server using Telnet. The server will convert the transaction to the appropriate format for the host type. 3270 SNA
The host that a WTP device connects to if the device is not explicitly linked to a host and it is running a 3270 application.
None, Predefined list, Prompt
<Prompt>
5250 SNA
The host that a WTP device connects to if the device is not explicitly linked to a host and it is running a 5250 application.
None, Predefined list, Prompt
<Prompt>
Telnet
The host that a WTP device connects to if the device is not explicitly linked to a host and it is running a Telnet application.
None, Predefined list, Prompt
<Prompt>
6-37
Page 140
DCS 300 User’s Manual
Setting Up the WTP Devices When you choose OK in the WTP Parameters dialog box, the WTP Devices dialog box appears. This dialog box generates logical names for each device. After you finish configuring the WTP devices and you choose OK, the RF Hosts Created for WTP dialog box appears. For help, see “About the RF Hosts Created for the WTP Network” in the next section.
Field
Description
Value
Default
Base logical name
The base name that the server uses to create a unique logical name for each device. The server appends a sequential 3-digit number to this name for each device.
1 to 13 alphanumeric characters
HOST
About the RF Hosts Created for the WTP Network If you are adding a WTP network, when you choose OK in the WTP Devices dialog box, the RF Hosts Created for WTP dialog box appears. This dialog box shows you the RF host instances that the DCS 300 has created to support your terminal license. If your terminal license is a Level 3 or a Level 4, you must assign each device to the RF host instance that you want it to communicate with. Each RF host instance supports up to 127 terminal sessions.
6-38