Page 121

Connecting to the Intermec RF Network

6

Configuring a UDP Plus Network You must configure a UDP Plus network if you want the DCS 300 to communicate with TRAKKER Antares terminals and JANUS UDP Plus devices. To configure a UDP Plus network 1. From the main menu, choose the type of communication you are using to connect the server to the host. 2. Choose Downline Network. Two buttons, Connection Points and Downline Devices, appear. 3. Choose Connection Points. The Connection Point List dialog box appears.

4. Choose Add, Edit, or Delete. If you choose Add, the Add a Downline Connection Point dialog box appears.

6-19

Page 122

DCS 300 User’s Manual

5. Choose UDP Plus and then choose Add. The UDP Plus Network Parameters dialog box appears. 6. Configure the UDP Plus network. For help, see “Adding a UDP Plus Network” in the next section. 7. Set any time parameters for the UDP Plus network. For help, see “Setting the Time Parameters” later in this chapter. 8. Define a default host for each type of host that the UDP Plus devices will communicate with. For help, see “Defining Default Hosts” later in this chapter. 9. Choose OK. The UDP Plus Devices dialog box appears. For help, see “Setting Up the UDP Plus Devices” later in this chapter. 10. Choose OK to return to the Connection Point List dialog box. 11. Choose Close to return to the main menu. 12. Enable all the UDP Plus devices that you want to communicate with the server. For help, see “Enabling the UDP Plus Devices” later in this chapter.

6-20

Page 123

Connecting to the Intermec RF Network

6

Adding a UDP Plus Network After you finish configuring the UDP Plus network and you choose OK, the UDP Plus Devices dialog box appears. For help, see “Setting Up the UDP Plus Devices” later in this chapter. To add a UDP Plus network •

From the Add a Downline Connection Point dialog box, choose UDP Plus and then choose Add. The UDP Plus Network Parameters dialog box appears.

6-21

Page 124

DCS 300 User’s Manual

Field

Description

Value

Default

Lower limit

The minimum time in milliseconds the server waits for an acknowledgment from the device before resending a transaction.

200 to 2000

300

Upper limit

The maximum time in milliseconds the server waits for an acknowledgment from the device before resending a transaction.

2000 to 60000

5000

Retries

The number of times the server tries to transmit to a device before it sets the device to “not responding.”

1 to 99

7

Inactivity timer

The amount of time in minutes the terminal can be “not responding” before it is set to “disconnected.”

0 to 3600

60

Local

The UDP port through which the server communicates with itself. This port must be different from the network port.

5001 to 65535

5550

Network

The UDP port that UDP Plus uses for communication. This port must match the network port that is configured on the terminal.

5001 to 65535

5555

Hot Standby Timeout

The number of seconds the server waits to receive an acknowledgment after delivering a transaction to a device.

1 to 9999

40

None, Unlimited, Maximum

Maximum 50

If it does not receive an acknowledgment, the server writes the transactions for the device to a Hot Standby file. The device receives its transactions from the Hot Standby file when it comes back online. Transactions held in volatile memory

The number of transactions the server keeps in volatile RAM before it begins to write them to a Hot Standby file. Choose None if you want transactions always written to the file. Choose Unlimited if you do not want transactions written to the file unless the time you set for the Hot Standby timeout expires. Choose Maximum and enter a maximum number of transactions. When the server has this number of transactions in RAM, it writes them to a file.

6-22

Page 125

Connecting to the Intermec RF Network

6

Setting the Time Parameters You can configure these time parameters between the server and the UDP Plus terminals. Broadcast Parameters These optional parameters allow the server to broadcast a time at certain intervals to all UDP Plus terminals. These parameters synchronize the terminals with the server. Append Parameters These optional parameters configure the server to stamp the date and time to incoming data. The timestamp is in the format: delimiterYYYY:MM:DD:HH:MM:SS

If you enable this feature, all messages have a timestamp with the hour and minute. You can also append the year, month, day, and seconds. Make sure that when you append the date and time to the incoming data, the maximum transaction data length will not exceed 1024 bytes. If the date and time that is appended is longer than the maximum transaction data length, the time append will be truncated. You cannot use this feature when running terminal emulation. Note: Do not enable time append on both the UDP Plus network and the terminal. If it is enabled on both, two timestamps are appended to incoming data. To set the time parameters •

From the UDP Plus Network Parameters dialog box, choose Time Parameters. The Configure Time Parameters dialog box appears.

6-23

Page 126

DCS 300 User’s Manual

Field

Description

Value

Default

Broadcast enabled

This check box determines if the server sends a time broadcast to all terminals in the UDP Plus network.

Check, Clear

Clear

Interval

This field specifies how often in minutes the server broadcasts the time. If you set this field to 0, no broadcast is made.

0 to 99

1

Append enabled

This check box determines if a timestamp is added to messages from terminals.

Check, Clear

Clear

Include Year

This check box adds a 4-digit year to the time.

Check, Clear

Clear

Include Month

This check box adds a 2-digit month to the time.

Check, Clear

Clear

Include Day

This check box adds a 2-digit day to the time.

Check, Clear

Check

Include Seconds

This check box adds a 2-digit seconds to the time.

Check, Clear

Clear

Delimiter

This character separates the data from the appended date and time.

1 alphanumeric or special character

>

Julian date

This check box determines if the date for the time is in a 3-digit Julian format.

Check, Clear

Clear

6-24

Page 127

Connecting to the Intermec RF Network

6

Defining Default Hosts You can define a default method for the UDP Plus devices to get a host name when they are communicating with different types of hosts. You can configure the UDP Plus devices to • explicitly link with a specific host. Click the down arrow on the right side of the field and choose a host that you have configured.

• prompt the user to enter a host name. Click the down arrow on the right side of the field and choose <Prompt>.

• not communicate with a host. Click the down arrow on the right side of the field and choose <none>.

To configure a specific device to communicate in a different way to a host, see “Configuring TE Links” in Chapter 8. To configure your link •

From the UDP Plus Network Parameters dialog box, choose Default Host Links. The UDP Plus Default Host Links dialog box appears.

Field

Description

Value

Default

3270 SNA

The method that the UDP Plus devices will use to get a host name when they communicate with 3270 SNA hosts.

None, Prompt, pre-defined list

Prompt

5250 SNA

The method that the UDP Plus devices will use to get a host name when they communicate with 5250 SNA hosts.

None, Prompt, pre-defined list

Prompt

Telnet (all)

The method that the UDP Plus devices will use to get a host name when they communicate with Telnet hosts.

None, Prompt, pre-defined list

Prompt

6-25

Page 128

DCS 300 User’s Manual

Setting Up the UDP Plus Devices When you choose OK in the UDP Plus Network parameters dialog box, the UDP Plus Devices dialog box appears. The DCS 300 must know the IP address for every UDP Plus terminal that it may communicate with. You can either use the DCS 300 to generate logical names for each terminal and use a DNS server to resolve the IP addresses or you can enter each terminal’s IP address. Use a DNS server If you use a DNS server, you do not need to enter the terminal’s IP address on the DCS 300. You only need to enter the number of terminals to enable, a base logical name, and the domain. The DCS 300 generates the logical names for the terminals and the DNS server resolves the IP addresses. However, you still need to enter the terminal’s IP address on the terminal. Enter each terminal’s IP address manually If you do not use a DNS server, you need to enter the terminal’s IP address on the DCS 300. However, the server can help you generate logical names and IP addresses for the terminals. You need to enter the number of terminals to enable, a starting IP address, and a subnet mask. The server generates an appropriate number of sequential logical names and IP addresses. Make sure that each IP address that the server generates for a terminal matches an IP address on a terminal.

6-26

Page 129

Connecting to the Intermec RF Network

Field

Description

Value

Default

Number of terminals to enable

The number of logical names that you want to enable to communicate with the server. The server also generates this number of IP addresses.

1 to 254

8

Use DNS

This check box determines if the server uses a DNS server to translate the logical name to an IP address.

Check, Clear

Clear

6

Note: Before you check this check box, you must first configure a DNS server in the DNS Configuration dialog box. Base logical name

The base name that the server uses to create a unique logical name for each terminal. The server appends a sequential 3-digit number to this name for each terminal.

1 to 13 alphanumeric characters

UDPP

Starting IP address

The starting IP address that the server uses to assign IP addresses to each terminal. The IP address must be a valid IP v4 address.

xxx.xxx.xxx.xxx where xxx is a value between 0 and 255

None

Subnet mask

The subnet mask that the server uses to validate the IP addresses. The server verifies that they do not cross a subnet boundary.

xxx.xxx.xxx.xxx where xxx is a value between 0 and 255

Based on starting IP address

Domain

The name of the domain that all of the terminals are in.

None

None

Note: If you check the Use DNS check box and you do not enter a domain, the server searches the domains that are listed in the DNS Configuration dialog box.

6-27

Page 130

DCS 300 User’s Manual

Enabling the UDP Plus Devices When you configured the UDP Plus network, you enabled a fixed number of UDP Plus terminals to communicate with the DCS 300. You can enable up to 254 UDP Plus terminals. Use the Device List dialog box to enable or disable IP addresses and logical names for terminals that you want to communicate with the server. Note: Do not enable devices that you are not using. If you try to send data to a nonexistent enabled device, your system performance will degrade. You can edit each terminal to change its logical name, IP address, device type, transaction IDs, and delivery responses. You can also use DNS to determine the device’s IP address or to edit an IP address. Your server is licensed to communicate with a fixed number of terminals (1-8, 1-24, 1-64, 1-254). The server does not keep track of the number of terminals you enable. You can enable all 254 terminals. As each terminal sends messages to the server, the server logs its logical name. When the server logs the maximum number of logical names that your terminal license allows, it will not accept messages from any new logical names. When you stop data collection on the server, the terminal license count number is reset. If you need to purchase an upgrade to your terminal license, contact your local Intermec representative. To enable the UDP Plus devices 1. From the main menu, choose the type of communication you are using to connect the server to the host. 2. Choose Downline Network. Two buttons, Connection Points and Downline Devices, appear. 3. Choose Downline Devices. The Device List dialog box appears.

6-28