Page 111
Connecting to the Intermec RF Network
6
Field
Description
Value
Default
Retry count
The number of times the RF card tries to transmit to a device.
0 to 255
64
BRU Status
This check box determines which BRUs are connected to the RF card.
Check, Clear
First BRU is checked, all others cleared.
Channel Frequency
The channel and frequency on which the BRU is communicating.
0 to 6
0. If 0 is being used, the next available value is used.
Repeat count
The number of repeaters that a message is allowed to pass through for this BRU.
0 to 7
0
1 to 9999
40
None, Unlimited, Maximum
Maximum 50
Note: Intermec recommends that a message does not pass through more than three repeaters. Hot Standby Timeout
The number of seconds the server waits to receive an acknowledgment after delivering a transaction to an RF device. If it does not receive an acknowledgment, the server writes the transactions for the RF device to a Hot Standby file. The RF device receives its transactions from this file when it comes back online.
Transactions held in volatile memory
The number of transactions the server keeps in volatile RAM before it begins to write them to a Hot Standby file. Choose None if you want transactions always written to the file. Choose Unlimited if you do not want transactions written to the file unless the time you set for the Hot Standby timeout expires. Choose Maximum and enter a maximum number of transactions. When the server has this number of transactions in RAM, it writes them to a file.
6-9
Page 112
DCS 300 User’s Manual
Setting the Time Parameters You can configure these time parameters between the BRUs and their devices. Broadcast Parameters These optional parameters let the server broadcast a time, with a short string, at certain intervals to all RF devices. These parameters synchronize the RF devices with the server. Append Parameters These optional parameters configure the BRUs to stamp the date and time to incoming data. The timestamp is in the format: delimiterYYYY:MM:DD:HH:MM:SS
If you enable this feature, all messages have a timestamp with the hour and minute. You can also append the year, month, day, and seconds. Make sure that when you append the date and time to the incoming data, the maximum transaction data length will not exceed 1024 bytes. If the date and time that is appended is longer than the maximum transaction data length, the time append will be truncated. This feature will not operate when running terminal emulation or using the direct TCP/IP socket interface. Note: Do not enable time append on both the RF card and the RF device. If it is enabled on both, two timestamps are appended to incoming data. To set the time parameters •
6-10
From the Configure Controller: RF card dialog box, choose Time Parameters. The Configure Time Parameters dialog box appears.
Page 113
Connecting to the Intermec RF Network
Field
Description
Value
Default
Broadcast enabled
This check box determines if the BRUs send a time broadcast to all devices communicating with them.
Check, Clear
Clear
Include Seconds
This check box adds seconds to the time.
Check, Clear
Clear
6
Note: If you are using JANUS devices to communicate with the BRUs, you must check this check box. Include Date
This check box adds the date to the time.
Check, Clear
Clear
Time format
These option buttons choose the time format.
12 hour, 24 hour
12 hour
Interval
This field specifies how often in minutes the server broadcasts the time. If you set this field to 0, no broadcast is made.
0 to 99
1
Preamble
This field lets you add a short message to the beginning of the time.
1 to 5 alphanumeric characters
None
Postamble
This field lets you add a short message to the end of the time.
1 to 5 alphanumeric characters
None
Append enabled
This check box determines if a timestamp is added to messages from devices.
Check, Clear
Clear
Include Year
This check box adds the 4-digit year to the time.
Check, Clear
Clear
Include Month
This check box adds the 2-digit month to the time.
Check, Clear
Clear
Include Day
This check box adds the 2-digit day to the time.
Check, Clear
Check
Include Seconds
This check box adds the 2-digit seconds to the time.
Check, Clear
Clear
Delimiter
This character separates the data from the appended date and time.
1 alphanumeric or special character
>
Julian date
This check box determines if the date is in a 3-digit Julian format.
Check, Clear
Clear
6-11
Page 114
DCS 300 User’s Manual
Defining Default Hosts You can define a default method for the RF card devices to get a host name when they are communicating with different types of hosts. You can configure the RF card devices to • explicitly link with a specific host. Click the down arrow on the right side of the field and choose a host that you have configured.
• prompt the user to enter a host name. Click the down arrow on the right side of the field and choose <Prompt>.
• not communicate with a host. Click the down arrow on the right side of the field and choose <none>.
To configure a specific device to communicate in a different way to a host, see “Configuring TE Links” in Chapter 8. To configure your link •
From the Configure Controller: RF card dialog box, choose Default Host Links. The RF Card Default Host Links dialog box appears.
Field
Description
Value
Default
3270 SNA
The method that the RF card devices will use to get a host name when they communicate with 3270 SNA hosts.
None, Prompt, pre-defined list
Prompt
5250 SNA
The method that the RF card devices will use to get a host name when they communicate with 5250 SNA hosts.
None, Prompt, pre-defined list
Prompt
Telnet (all)
The method that the RF card devices will use to get a host name when they communicate with Telnet hosts.
None, Prompt, pre-defined list
Prompt
6-12
Page 115
Connecting to the Intermec RF Network
6
Defining the RF Card Devices When you choose OK in the Configure Controller: RF Card dialog box, this dialog box appears.
Field
Description
Value
Default
Base logical name
The base name that the server uses to create a unique logical name for each device. The server appends a sequential 3-digit number to this name for each device.
1 to 13 alphanumeric characters
ISA1
Number of devices to enable
The number of logical names that you want to enable to communicate with the server.
1 to 128
8
6-13
Page 116
DCS 300 User’s Manual
Enabling the RF Card Devices When you configured the RF card, you enabled a fixed number of RF card devices to communicate with the DCS 300. You can enable up to 128 RF card devices. Use the Device List dialog box to enable or disable addresses and logical names for devices that you want to communicate with the server. Note: Do not enable devices that you are not using. If you try to send data to a nonexistent enabled device, your system performance will degrade. You can edit each device to change its logical name, device type, transaction IDs, and delivery responses. Your server is licensed to communicate with a fixed number of devices (1-8, 1-24, 1-64, 1-254). The server does not keep track of the number of devices you enable. You can enable all 254 devices. As each device sends messages to the server, the server logs its logical name. When the server logs the maximum number of logical names that your terminal license allows, it will not accept messages from any new logical names. When you stop data collection on the server, the terminal license count number is reset. If you need to purchase an upgrade to your terminal license, contact your local Intermec representative. Note: Each BRU only supports 32 devices. There fore, the maximum number of devices you can enable is 224 (7 BRUs x 32 devices). However, Intermec recommends that you do not enable more than 128 devices for maximum throughput. To enable the RF card devices 1. From the main menu, choose the type of communication you are using to connect the server to the host. 2. Choose Downline Network. Two buttons, Connection Points and Downline Devices, appear. 3. Choose Downline Devices. The Device List dialog box appears.
6-14
Page 117
Connecting to the Intermec RF Network
6
Device List Dialog Box
4. In the Connection field, click the down arrow on the right side of the field. A list of the connection points that you have configured appears. Select the RF card for which you want to enable devices. 5. To enable all 128 devices, choose Enable All. Or, to enable specific devices, select the device you want to enable and make sure there is a check in the Enabled check box. 6. To disable all 128 devices, choose Disable All. Or, to disable specific devices, select the device you want to disable and make sure there is no check in the Enabled check box. 7. Select a terminal whose individual parameters you want to edit and then choose Edit Device. For help, see “Editing an RF Card Device” in the next section. 8. Choose OK to save your changes and return to the main menu.
6-15
Page 118
DCS 300 User’s Manual
Editing an RF Card Device •
From the Device List dialog box, choose Edit Device. The Device Parameters dialog box appears. Note: If you are using terminal emulation, do not configure transaction IDs or delivery responses.
6-16
Page 119
Connecting to the Intermec RF Network
Field
Description
Value
Default
Logical name
The logical name of the device.
1 to 16 alphanumeric characters
ISA1XXX
Able to receive data
This check box determines if this device can receive data from the network.
Check, Clear
Check
Device type
This list box contains the current Intermec devices that are supported.
Predefined list
J2020
Auto-insert from device
This field provides a transaction ID for this device if it cannot put a transaction ID in its transactions.
Predefined list
None
6
Note: All transactions from this terminal will be routed using this transaction ID. To be routed to device
This field contains a transaction ID that will always be routed to this device.
Predefined list
None
Interactive response (Optional)
The message that is sent to the source of the transaction if the transaction is delivered successfully to this device in Interactive mode.
1 to 39 characters
None
Hot standby (Optional)
The message that is sent to the source of the transaction if the transaction for this device is written to a Hot Standby file.
1 to 40 characters
None
6-17
Page 120
DCS 300 User’s Manual
Connecting the DCS 300 to the UDP Plus Network The DCS 300 supports communications with Intermec’s UDP Plus network (2.4 GHz RF network) through access points that are connected to the Ethernet or token ring network. You can run standard TCP/IP applications, such as FTP, with the server. The illustration on the next page shows an example of a DCS 300 connected to the UDP Plus network. You can also use the server to route any IP traffic from one subnet to the server. For example, if the server is connected to a twinaxial host, it can pass IP traffic from an Ethernet network to the host and back. Refer to the figure on the next page. The UDP Plus network consists of access points communicating with various JANUS devices and TRAKKER Antares terminals. •
Access points act as bridges between the Ethernet or token ring network and Intermec’s UDP Plus network. All terminals communicating in this network must have the same domain and security ID.
•
TRAKKER Antares terminals, such as the T2425, are terminals with network support. The server supports these terminals using Intermec’s UDP Plus network. Follow the instructions “Configuring a UDP Plus Network” later in this chapter.
•
JANUS UDP Plus devices, such as the JG2020, are hand-held data collection computers with network support. The server communicates with these terminals using UDP Plus. The JANUS devices support both Novell NetWare Client for DOS and Novell LAN Workplace for DOS. Intermec recommends that you use LAN Workplace to provide the TCP/IP protocol stack.
Example: The DCS 300 Connected to the Intermec UDP Plus Network Host
T2425
JG2020
JG2050 Access point
DCS 300
Ethernet 0300U.014
6-18