Page 72

4. Output transmission settings data reformatting (EasySet 2.01, 2.02, 2.03)

Reformatting menu options The different reformatting functions are provided in 3 popup menus depending on where you click in the "Define output" page. Select the Reset formatting pushbutton or menu option to reset formatting for the selected scenario.

Input string popup menu

Delete selection deletes one or more characters from the input string at the selected location

Move before / after moves one or more characters in the input string to a new location in the output string

Copy before / after copies one or more characters in the input string to another location in the output string in the output string, click the location where you want to move the characters – they will be moved before or after this location as requested in the output string, click the location where you want to copy the characters – they will be copied before or after this location as requested

Delete / Replace systematically popup menu Delete systematically deletes all occurrences of the specified character from the input string regardless of their location Replace systematically replaces all occurrences of a given character in the input string by the specified replacement character

72

MicroBar 9730 - Installation Manual

Page 73

4. Output transmission settings data reformatting (EasySet 2.01, 2.02, 2.03) Output string popup menu

Insert before / after systematically inserts one or more characters in the output string in the output string, click the location where you want to insert the new characters – they will be inserted before or after this location as requested

Input string grid input string index : input string with input mask characters if applicable :

Output string grid input string index: reformatting action indicators : output string index : output string with specified characters if applicable :

MicroBar 9730 - Installation Manual

73

Page 74

4. Output transmission settings data reformatting (EasySet 2.01, 2.02, 2.03)

reformatting action indicators Reformatting actions are indicated in the second row of the Output string grid by reformatting action indicator characters.

74 reformatting action indicator action popup menu d m c (d) (r) i

Delete selection Move before / after Copy before / after Delete systematically Replace systematically Insert before / after

Input string Input string Input string Delete / Replace systematically Delete / Replace systematically Output string

MicroBar 9730 - Installation Manual

Page 75

4. Output transmission settings postamble postamble [message_length] [LRC]

[preamble]

[input_id]

[symbology_id]

<data>

[input_id]

[postamble] keyboard wedge none

\45\54\3E\00\60

Enter (*)

\45\54\04\02\01\60

Carriage Return

\45\54\04\02\02\60

Tab

\45\54\04\02\08\60

Field Advance

\45\54\04\02\04\60

Field Exit

\45\54\04\02\05\60

MicroBar 9730 - Installation Manual

75

Page 76

4. Output transmission settings postamble Down Arrow

\45\54\04\02\0F\60 compose:

\45\54\60

- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - maximum = 10 characters - wedge PC : for characters with ASCII values from 01h to 1Fh (SOH to US), the value transmitted corresponds to <Ctrl> + <letter> (SOH = <Ctrl A>, STX = <Ctrl B>, . . .)

76 character transmitted as

SOH STX ETX EOT ENQ ACK BELL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4

<Ctrl A> <Ctrl B> <Ctrl C> <Ctrl D> <Ctrl E> <Ctrl F> <Ctrl G> <Ctrl H> <Ctrl I> <Ctrl J> <Ctrl K> <Ctrl L> <Ctrl M> <Ctrl N> <Ctrl O> <Ctrl P> <Ctrl Q> <Ctrl R> <Ctrl S> <Ctrl T>

MicroBar 9730 - Installation Manual

Page 77

4. Output transmission settings postamble character transmitted as

NACK SYN ETB CAN EM SUB ESC FS GS RS US

<Ctrl U> <Ctrl V> <Ctrl W> <Ctrl X> <Ctrl Y> <Ctrl Z> <Ctrl [> <Ctrl \> <Ctrl ]> <Ctrl ^> <Ctrl _>

[input_id]

[symbology_id]

RS-232 [message_length] [LRC]

[preamble]

<data>

[input_id]

[postamble] none

\45\54\3E\00\60

Carriage Return + Line Feed (*)

\45\54\3E\0D\3E\0A\60

Carriage Return

\45\54\3E\0D\60

Line Feed

\45\54\3E\0A\60

MicroBar 9730 - Installation Manual

77

Page 78

4. Output transmission settings postamble compose:

\45\54\60 enter an ASCII string and scan End Selection (Appendix A) maximum = 10 characters preamble / postamble [message_length] [LRC]

[preamble]

[input_id]

[symbology_id]

<data>

[input_id]

[postamble]

STX / ETX

\45\53\3E\02\45\54\3E\03\60

78

MicroBar 9730 - Installation Manual