The text of a manual · part 9 of 25
MicroBar 9730 Decoder Installation Manual: 4. Output transmission settings, pages 72 to 78
Pages 72 to 78 of 200, from MicroBar 9730 Decoder Installation Manual
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9730
Page 72
4. Output transmission settings data reformatting (EasySet 2.01, 2.02, 2.03)
Reformatting menu options The different reformatting functions are provided in 3 popup menus depending on where you click in the "Define output" page. Select the Reset formatting pushbutton or menu option to reset formatting for the selected scenario.
Input string popup menu
Delete selection deletes one or more characters from the input string at the selected location
Move before / after moves one or more characters in the input string to a new location in the output string
Copy before / after copies one or more characters in the input string to another location in the output string in the output string, click the location where you want to move the characters – they will be moved before or after this location as requested in the output string, click the location where you want to copy the characters – they will be copied before or after this location as requested
Delete / Replace systematically popup menu Delete systematically deletes all occurrences of the specified character from the input string regardless of their location Replace systematically replaces all occurrences of a given character in the input string by the specified replacement character
72
MicroBar 9730 - Installation Manual
Page 73
4. Output transmission settings data reformatting (EasySet 2.01, 2.02, 2.03) Output string popup menu
Insert before / after systematically inserts one or more characters in the output string in the output string, click the location where you want to insert the new characters – they will be inserted before or after this location as requested
Input string grid input string index : input string with input mask characters if applicable :
Output string grid input string index: reformatting action indicators : output string index : output string with specified characters if applicable :
MicroBar 9730 - Installation Manual
73
Page 74
4. Output transmission settings data reformatting (EasySet 2.01, 2.02, 2.03)
reformatting action indicators Reformatting actions are indicated in the second row of the Output string grid by reformatting action indicator characters.
74 reformatting action indicator action popup menu d m c (d) (r) i
Delete selection Move before / after Copy before / after Delete systematically Replace systematically Insert before / after
Input string Input string Input string Delete / Replace systematically Delete / Replace systematically Output string
MicroBar 9730 - Installation Manual
Page 75
4. Output transmission settings postamble postamble [message_length] [LRC]
[preamble]
[input_id]
[symbology_id]
<data>
[input_id]
[postamble] keyboard wedge none
\45\54\3E\00\60
Enter (*)
\45\54\04\02\01\60
Carriage Return
\45\54\04\02\02\60
Tab
\45\54\04\02\08\60
Field Advance
\45\54\04\02\04\60
Field Exit
\45\54\04\02\05\60
MicroBar 9730 - Installation Manual
75
Page 76
4. Output transmission settings postamble Down Arrow
\45\54\04\02\0F\60 compose:
\45\54\60
- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - maximum = 10 characters - wedge PC : for characters with ASCII values from 01h to 1Fh (SOH to US), the value transmitted corresponds to <Ctrl> + <letter> (SOH = <Ctrl A>, STX = <Ctrl B>, . . .)
76 character transmitted as
SOH STX ETX EOT ENQ ACK BELL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4
<Ctrl A> <Ctrl B> <Ctrl C> <Ctrl D> <Ctrl E> <Ctrl F> <Ctrl G> <Ctrl H> <Ctrl I> <Ctrl J> <Ctrl K> <Ctrl L> <Ctrl M> <Ctrl N> <Ctrl O> <Ctrl P> <Ctrl Q> <Ctrl R> <Ctrl S> <Ctrl T>
MicroBar 9730 - Installation Manual
Page 77
4. Output transmission settings postamble character transmitted as
NACK SYN ETB CAN EM SUB ESC FS GS RS US
<Ctrl U> <Ctrl V> <Ctrl W> <Ctrl X> <Ctrl Y> <Ctrl Z> <Ctrl [> <Ctrl \> <Ctrl ]> <Ctrl ^> <Ctrl _>
[input_id]
[symbology_id]
RS-232 [message_length] [LRC]
[preamble]
<data>
[input_id]
[postamble] none
\45\54\3E\00\60
Carriage Return + Line Feed (*)
\45\54\3E\0D\3E\0A\60
Carriage Return
\45\54\3E\0D\60
Line Feed
\45\54\3E\0A\60
MicroBar 9730 - Installation Manual
77
Page 78
4. Output transmission settings postamble compose:
\45\54\60 enter an ASCII string and scan End Selection (Appendix A) maximum = 10 characters preamble / postamble [message_length] [LRC]
[preamble]
[input_id]
[symbology_id]
<data>
[input_id]
[postamble]
STX / ETX
\45\53\3E\02\45\54\3E\03\60
78
MicroBar 9730 - Installation Manual