Page 63

4. Output transmission settings symbology identifier UPC-A: [range: 2]

\45\59\08\60 enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) default = A UPC-E: [range: 2]

\45\59\09\60

- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - default = E

MicroBar 9730 - Installation Manual

63

Page 64

4. Output transmission settings data editing (EasySet 3.0 and later)

data editing (EasySet 3.0 and later) - the MicroBar can edit the data it receives before it transmits it to the host system - define up to 7 input scenarios to filter out the data you want to edit - the order in which you define the scenarios is important (the MicroBar compares incoming data with each scenario in turn and edits the data for the first matching scenario it finds) - data editing is applied before keyboard remapping !!! (if applicable) - if the data editing and scale solicitation functions have an identical input scenario, data editing has priority (scale solicitation will not occur !!!) reset scenarios in MicroBar

\4A\47\00\00\60 resets all 7 scenarios and editing in the MicroBar (recommended before you define new scenarios and editing) define: this option only available with EasySet 1. define the input data you want to intercept for editing : - select any combination of input port, input type (symbology, RS-232...), message length, input mask 2. define the editing you want to apply to this input : - select a scenario - define the editing for the selected scenario - input mask : - you can use up to 24 consecutive characters (or more if you start with a string of '?' wildcards to indicate the start position of the actual filter) - '*', '?', '<num>', '<not num>' are wildcards

64

MicroBar 9730 - Installation Manual

Page 65

4. Output transmission settings data editing (EasySet 3.0 and later) - use a backslash '\' in front of '*', '?' and '\' if you want to include them as actual characters in your filter ('\*' = '*', '\?' = '?', '\\' = '\') - '<num>' and '<not num>' are available in a right-click popup menu in the "Input mask" field - make sure that the input scenarios you define actually correspond to incoming data conditions !!! - correct input port (no value = 'any port') - correct input type (no value = 'any input type') - correct message length (no value = 'any length') - correct input characters')

mask

(no value

=

'any

- data editing is applied before keyboard remapping !!! (if applicable) - if the data editing and scale solicitation functions have an identical input scenario, data editing has priority (scale solicitation will not occur !!!)

MicroBar 9730 - Installation Manual

65

Page 66

4. Output transmission settings data reformatting (EasySet 2.01, 2.02, 2.03)

data reformatting (EasySet 2.01, 2.02, 2.03) - reformats the data received before transmission to the host system - input data is selected for reformatting by user-defined input scenarios - if the MicroBar finds a matching scenario, it applies the reformatting for that scenario - scenarios can be saved in a file reset

\4A\47\00\00\60 resets all 5 scenarios and reformatting in the MicroBar define reformatting this option only available with EasySet 1. define the input data for reformatting - select any combination of input port, input type (symbology, RS-232...), message length or input mask - input mask : use up to three consecutive constants and wildcards * and ? (a wildcard preceded by a backslash is interpreted as a constant : \* = *, \? = ?, \\ = \) 2. define the output reformatting you want to apply to this input - select a scenario - define the reformatting for the selected scenario

Overview The MicroBar receives data from a wide range of input devices and transmits this data to the host system. The data can be transmitted exactly as it is received, or it can be "reformatted" (modified to suit the requirements of the host application) by the MicroBar before it is transmitted.

66

MicroBar 9730 - Installation Manual

Page 67

4. Output transmission settings data reformatting (EasySet 2.01, 2.02, 2.03) There are 2 "pages" in the reformatting tool : "Define input" and "Define output". In the "Define input" page, you can define which input data you want the MicroBar to reformat (up to 5 input scenarios for each port). In the "Define output" page, you can select 5 different input scenarios and define the output reformatting you want the MicroBar to apply for each scenario. When the MicroBar receives an input string, it looks at each of the 5 scenarios in turn (starting with scenario 1) to see if there is a matching scenario. As soon as the MicroBar finds a matching scenario, it applies the reformatting defined for that scenario and sends the reformatted data string to the host system.

General functions Open opens a file containing a saved set of scenarios and displays the scenarios in the "Reformat data" window Save saves the current set of scenarios to a file (the associated reformatting is not saved)

Define input displays the "Define input" page where you define the different input scenarios you want the MicroBar to detect for reformatting Define output displays the "Define output" page where you choose one of the input scenarios and define the reformatting you want the MicroBar to apply to the matching input string

MicroBar 9730 - Installation Manual

Reset all resets all the scenarios and reformatting in the "Reformat data" window (does not affect scenarios and reformatting in the MicroBar)

OK sends the currently selected scenario and associated reformatting command to the setup sheet / MicroBar (replaces the corresponding scenario in the MicroBar) Cancel closes the "Reformat data" window

67

Page 68

4. Output transmission settings data reformatting (EasySet 2.01, 2.02, 2.03)

"Define input" page 1 - Define input choose a Port button to tell the MicroBar to reformat input data received on that port Example: select "Port 4" if that's where the data to be reformatted is coming in choose an Input type if you only want reformatting for a given symbology, RS-232 input or magstripe input Example: select "Code 128" if you only want to reformat Code 128 data if you leave the "Input type" field empty, the MicroBar will reformat any type of data received on the selected port define a Length if you only want the MicroBar to reformat input data of a certain length Example: enter "10" if you only want to reformat messages if they are 10 characters long if you leave the "Length" field empty, the MicroBar will reformat input messages of any length received on the selected port enter an Input mask if the input messages you want to reformat can be identified by specific characters in a specific position Example: enter "+H" if you only want to reformat messages which begin with the characters "+H" if you leave the "Input mask" field empty, the MicroBar will reformat input messages with any characters received on the selected port

Input mask restrictions You can only enter 1, 2 or 3 consecutive "search" characters in a mask. The total number of characters in the mask cannot be longer than the fixed length selected in the "Length" field (if applicable).

68

MicroBar 9730 - Installation Manual

Page 69

4. Output transmission settings data reformatting (EasySet 2.01, 2.02, 2.03)

Using wildcards in the input mask You can use character substitution wildcards like the ones used in file searches etc. to indicate where the search string is located in the message: * replaces any number of characters (any characters)

?

replaces 1 character (any character)

It is not necessary to add wildcard characters after the string of 1, 2 or 3 character constants. If you want to look for the characters * ? \ in the input message, you must put an additional backslash in front of these characters to distinguish them from wildcard characters.

Examples

Input mask input string reformatting ?

???gg abcggdefg yes aggdefg no abcggdefg yes aggdefg yes

*ggdefg yes aggdefg no

*gg

\*gg

MicroBar 9730 - Installation Manual

69

Page 70

4. Output transmission settings data reformatting (EasySet 2.01, 2.02, 2.03)

"Define output" page 2 - Choose a scenario 5 list boxes contain a list of all the input scenarios defined in the "Define input" page choose a scenario corresponding to the input data you want to reformat Example: select " Port 4 Code 128 10 +H " in list box 1

3 - Define output Input string (blue) shows the original format of the data received including message length and input mask characters if applicable Output string shows changes made to the input string (blue) and the resulting output string (yellow) after reformatting

1. select the input scenario you want the MicroBar to detect 2. define the reformatting you want to apply for that scenario according to what you want to do : - select one or more characters in the Input string and choose a menu option - click in the Delete / Replace systematically area and choose a menu option - select a character location in the Output string and choose a menu option 3. click OK to send the <input scenario + reformatting> to the MicroBar grid length Before refomatting, grid length is limited to 200 characters if no length is specified in the "Length" field for the selected scenario. The maximum grid length is 2000 characters (maximum input string length).

70

MicroBar 9730 - Installation Manual

Page 71

4. Output transmission settings data reformatting (EasySet 2.01, 2.02, 2.03)

Reformatting restrictions You can only perform one reformatting action at a time on the chosen input scenario. You can only send one input-scenario-with-reformatting combination at a time to the MicroBar. The MicroBar stores 5 input-scenario-with-reformatting combinations. If you send scenario 1 and associated reformatting, you will replace the current scenario 1 stored in the MicroBar, if you send scenario 2, you will replace scenario 2, etc.

Unexpected results As more than one scenario in the MicroBar can match the input string received, this can give unexpected reformatting results. Example - you define reformatting for scenario 4 - both scenario 2 and scenario 4 match the input string - the MicroBar applies the reformatting defined for scenario 2 (the first matching scenario) To limit the risk of this happening, you can : - use the data reformatting - reset command in EasySet to clear the 5 scenarios in the MicroBar - always start with scenario 1, then scenario 2, etc. when you define new reformatting

MicroBar 9730 - Installation Manual

71