Page 54

4. Output transmission settings preamble compose:

\45\53\60

- enter an ASCII string and scan End Selection (Appendix A) - maximum = 10 characters preamble / postamble [message_length] [LRC]

[preamble]

[input_id]

[symbology_id]

<data>

[input_id]

[postamble]

STX / ETX

\45\53\3E\02\45\54\3E\03\60

54

MicroBar 9730 - Installation Manual

Page 55

4. Output transmission settings input port identifier input port identifier [message_length] [LRC]

[preamble]

[input_id]

[symbology_id]

<data>

[input_id]

[postamble]

- the MicroBar can send an input identification string before or after the barcode data to identify the input port (and input device !) used

2

4

3

1

5

4 6 position [message_length] [LRC]

[preamble]

[input_id]

[symbology_id]

<data>

[input_id]

[postamble] before barcode data (*)

\4A\46\00\00\01\60 after barcode data

\4A\46\00\00\02\60

MicroBar 9730 - Installation Manual

55

Page 56

4. Output transmission settings input port identifier port 1 (wedge Y cable / RS-232) / port 3 (wedge 2 cables) - 1 pen input device - input port depends on host interface / cable configuration none (*)

\4A\46\00\01\00\60 compose: [range: 15]

\4A\46\01\01\60

- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - maximum = 15 characters port 4 - true RS-232 C input device, undecoded laser gun, CCD scanner in laser emulation, 1 pen, 2 pens with dual pen adaptor - dual pen adaptor provides an extra port (port 6) for port 4 none (*)

\4A\46\00\04\00\60 compose: [range: 15]

\4A\46\01\04\60

- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - maximum = 15 characters

56

MicroBar 9730 - Installation Manual

Page 57

4. Output transmission settings input port identifier port 5 - RS-232 TTL input device, undecoded laser gun, CCD scanner in laser emulation, 1 pen, undecoded magstripe reader none (*)

\4A\46\00\05\00\60 compose: [range: 15]

\4A\46\01\05\60

- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - maximum = 15 characters port 6 - 1 pen in extra port provided by a dual pen adaptor on port 4 none (*)

\4A\46\00\06\00\60 compose: [range: 15]

\4A\46\01\06\60

- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - maximum = 15 characters

MicroBar 9730 - Installation Manual

57

Page 58

4. Output transmission settings symbology identifier symbology identifier [message_length] [LRC]

[preamble]

[input_id]

[symbology_id]

<data>

[input_id]

[postamble]

AIM [message_length] [preamble] [input_id] [symbology_id] <data> [input_id] [postamble] [LRC] - optional 3-character symbology identifiers standardized by the AIM Committee Example: " ] A 0 " identifies standard Code 39 without check digit - refer to the official AIM documentation on symbology identifiers for full information on the different processing options supported symbology

]

<symbology_id>

<processing_option>

Ames Code Codabar Code 11 Code 39 Code 93 Code 128/EAN 128 Interleaved 2 of 5 Matrix 2 of 5 Standard 2 of 5 MSI Code Plessey Code Telepen UPC/EAN (1) UPC/EAN (2)

] ] ] ] ] ] ] ] ] ] ] ] ] ]

X F H A G C I X S M P B E X

0 0, 2, 4 0, 1, 2 0, 1, 2, 4 0 0, 1 0, 1, 2 0 0, 1, 2 0, 1 0 0, 1 0, 3, 4 0

(1) UPC/EAN "standard" lengths = 8, 13, 15 (add-on 2), 18 (add-on 5) characters (2) UPC/EAN other lengths (no check digit, . . .)

58

MicroBar 9730 - Installation Manual

Page 59

4. Output transmission settings symbology identifier not transmitted (*)

\47\59\60 transmitted

\47\58\60

- activates AIM symbology identifier transmission for all symbologies custom [message_length] [LRC]

[preamble]

[input_id]

[symbology_id]

<data>

[input_id]

[postamble] not transmitted (*)

\45\56\60 transmitted

\45\55\60

- activates custom symbology transmission for all symbologies

MicroBar 9730 - Installation Manual identifier

59

Page 60

4. Output transmission settings symbology identifier compose - symbology identifier = 1 or 2 characters Ames Code: [range: 2]

\45\59\05\60 enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) default = * Codabar: [range: 2]

\45\59\04\60

- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - default = D Code 11: [range: 2]

\45\59\10\60 enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) default = * Code 39: [range: 2]

\45\59\01\60

- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - default = *

60

MicroBar 9730 - Installation Manual

Page 61

4. Output transmission settings symbology identifier Code 93: [range: 2]

\45\59\0D\60 enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) default = D Code 128 / EAN 128: [range: 2]

\45\59\0B\60

- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - default = D EAN-8: [range: 2]

\45\59\07\60 enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) default = FF EAN-13: [range: 2]

\45\59\06\60

- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - default = F Interleaved 2 of 5: [range: 2]

\45\59\02\60 enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) default = I

MicroBar 9730 - Installation Manual

61

Page 62

4. Output transmission settings symbology identifier Matrix 2 of 5: [range: 2]

\45\59\0E\60

- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - default = D MSI Code: [range: 2]

\45\59\0A\60 enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) default = D Plessey Code: [range: 2]

\45\59\0C\60

- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - default = D Standard 2 of 5: [range: 2]

\45\59\03\60 enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) default = D Telepen: [range: 2]

\45\59\0F\60

- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - default = *

62