Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 25

MicroBar 9730 Decoder Installation Manual: 4. Output transmission settings, pages 45 to 53

Pages 45 to 53 of 200, from MicroBar 9730 Decoder Installation Manual

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 9730

Page 45

4. Output transmission settings RS-232 active

\4C\60 low RTS idle (*)

\48\5C\60

RTS/CTS not active : MicroBar maintains the low level on the RTS pin RTS/CTS active : MicroBar applies the normal RTS/CTS protocol high RTS idle

\48\5D\60

- RTS/CTS not active : MicroBar maintains the high level on the RTS pin - RTS/CTS active : MicroBar reverses the levels (but not the data) of the RTS/CTS protocol (high becomes low and low becomes high)

LRC (longitudinal redundancy check) - checksum which your application can use to validate the data transmitted to the host system 1. XOR is calculated for the hex values of the first two ASCII characters received 2. XOR is calculated for the next character against the result of the previous XOR calculation (repeated for all characters in the message) 3. two ASCII characters corresponding to the two digits of the final hex value are added to the end of the transmitted message

MicroBar 9730 - Installation Manual

45

Page 46

4. Output transmission settings RS-232 Example (data received = C O D E - 3 9 <CR> <LF>) ASCII hex binary

C O ... D ... E ... ... 3 ... 9 ... <CR> ... <LF> ...

43h 4Fh XOR : 44h XOR : 45h XOR : 2Dh XOR : 33h XOR : 39h XOR : 0Dh XOR : 0Ah XOR :

0100 0011 0100 1111 0000 1100 0100 0100 0100 1000 0100 0101 0000 1101 0010 1101 0010 0000 0011 0011 0001 0011 0011 1001 0010 1010 0000 1101 0010 0111 0000 1010 0010 1101

- hex value for 0010 1101 = 2Dh - transmitted message = C O D E - 3 9 <CR> <LF> 2 D not active (*)

\4F\60 active

\4E\60

46

MicroBar 9730 - Installation Manual

Page 47

4. Output transmission settings RS-232 inter-character delay (output to host) - avoids dropping characters if transmitting decoded data too fast for the host system none (*)

\52\00\60

10 ms

\52\0A\60

20 ms

\52\14\60

30 ms

\52\1E\60

40 ms

\52\28\60

50 ms

\52\32\60 compose (ms): [range: 1-999 ms]

\52\60 enter a number string and scan End Selection (Appendix C)

MicroBar 9730 - Installation Manual

47

Page 48

4. Output transmission settings RS-232 inter-message delay (output to host) - gives the host system enough time to process each message received, especially when the host must act on end-of-message control codes such as <Enter> - "rolling buffer" operation : 1. a new inter-message delay cycle is activated each time the MicroBar receives a message 2. if the MicroBar receives a new message before the end of the inter-message delay, it stores the previous message in a "rolling buffer" memory and the cycle starts again 3. when no more messages are received before the end of an inter-message delay cycle, all the messages stored in the buffer are transmitted to the host system (First-In-First-Out, each message separated by the inter-message delay) none (*)

\53\00\60

100 ms

\53\01\24\60

500 ms

\53\07\34\60

1000 ms (1 sec)

\53\0F\28\60

2000 ms (2 sec)

\53\1F\10\60

5000 ms (5 sec)

\53\01\0E\08\60

48

MicroBar 9730 - Installation Manual

Page 49

4. Output transmission settings RS-232 compose (ms): [range: 1-6000 ms]

\53\60 enter a number string and scan End Selection (Appendix C)

MicroBar 9730 - Installation Manual

49

Page 50

4. Output transmission settings message length information message length information [message_length] [preamble] [input_id] [symbology_id] [LRC] - message length = all characters transmitted : [preamble] + [LRC]

+

[input_id]

+

[symbology_id]

+

<data>

<data>

+

[input_id]

[input_id]

+

[postamble]

[postamble] not transmitted (*)

\4A\4B\00\60 transmitted as 2 ASCII decimal digits

\4A\4B\0F\60

- available for 99 characters max transmitted as 2 ASCII hexadecimal digits

\4A\4B\07\60 available for 255 characters max transmitted as 1 ASCII decimal digit

\4A\4B\0B\60

- available for 9 characters max transmitted as 1 ASCII hexadecimal digit

\4A\4B\03\60 available for 15 characters max

50

MicroBar 9730 - Installation Manual

Page 51

4. Output transmission settings message length information transmitted as 8-bit value

\4A\4B\09\60

- available for 255 characters max transmitted as 16-bit value

\4A\4B\0D\60 available for 65535 (64 K) characters max (most significant byte transmitted first)

MicroBar 9730 - Installation Manual

51

Page 52

4. Output transmission settings preamble preamble [message_length] [LRC]

[preamble]

[input_id]

[symbology_id]

<data>

[input_id]

[postamble]

[preamble]

[input_id]

[symbology_id]

<data>

[input_id]

[postamble] keyboard wedge [message_length] [LRC] none (*)

\45\53\3E\00\60 compose:

\45\53\60

- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - maximum = 10 characters - wedge PC : for characters with ASCII values from 01h to 1Fh (SOH to US), the value transmitted corresponds to <Ctrl> + <letter> (SOH = <Ctrl A>, STX = <Ctrl B>, . . .)

52 character transmitted as

SOH STX ETX EOT ENQ ACK BELL BS

<Ctrl A> <Ctrl B> <Ctrl C> <Ctrl D> <Ctrl E> <Ctrl F> <Ctrl G> <Ctrl H>

MicroBar 9730 - Installation Manual

Page 53

4. Output transmission settings preamble character transmitted as

HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NACK SYN ETB CAN EM SUB ESC FS GS RS US

<Ctrl I> <Ctrl J> <Ctrl K> <Ctrl L> <Ctrl M> <Ctrl N> <Ctrl O> <Ctrl P> <Ctrl Q> <Ctrl R> <Ctrl S> <Ctrl T> <Ctrl U> <Ctrl V> <Ctrl W> <Ctrl X> <Ctrl Y> <Ctrl Z> <Ctrl [> <Ctrl \> <Ctrl ]> <Ctrl ^> <Ctrl _>

[input_id]

[symbology_id]

RS-232 [message_length] [LRC]

[preamble]

<data>

[input_id]

[postamble] none (*)

\45\53\3E\00\60

MicroBar 9730 - Installation Manual

53