The text of a manual · part 5 of 25
MicroBar 9730 Decoder Installation Manual: 4. Output transmission settings, pages 36 to 44
Pages 36 to 44 of 200, from MicroBar 9730 Decoder Installation Manual
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9730
Page 36
4. Output transmission settings keyboard wedge upper case
\41\45\60
36
MicroBar 9730 - Installation Manual
Page 37
4. Output transmission settings RS-232
RS-232 - default values (*) are for standard RS-232 C (9600, 7, E, 2)
baud rate 75
\41\00\60
150
\41\01\60
300
\41\02\60
600
\41\03\60
1200
\41\04\60
2400
\41\05\60
4800
\41\06\60
MicroBar 9730 - Installation Manual
37
Page 38
4. Output transmission settings RS-232 9600 (*)
\41\07\60
19200
\41\08\60
38400
\41\09\60 data bits 7 (*)
\42\60
8
\43\60 parity even (*)
\46\01\60 odd
\46\02\60 mark
\46\03\60
38
MicroBar 9730 - Installation Manual
Page 39
4. Output transmission settings RS-232 space
\46\04\60 none
\46\00\60 stop bits 1
\44\60
2 (*)
\45\60 hardware/software protocols timeout - the same timeout applies to all RS-232 protocols supported (ENQ/ACK/NAK, XON/XOFF, RTS/CTS) 1000 ms (*)
\51\0F\28\60 unlimited
\51\00\60
MicroBar 9730 - Installation Manual
39
Page 40
4. Output transmission settings RS-232 compose (ms): [range: 0-2500 ms]
\51\60 enter a number string and scan End Selection (Appendix C)
ENQ - activating ENQ activates the ENQ protocol - ENQ not used: - barcode data is transmitted without waiting for a request from the host system - ENQ used: - data is transmitted when ENQ character received from host system before end of hardware/software protocols time-out - "beep after transmission" if good read ("beep before transmission" also possible - see section 7, "Operating settings") - 6 error beeps and no transmission if no ENQ received before end of timeout - ENQ/ACK/NAK exclusive with XON/XOFF and RTS/CTS not used (*)
\47\3E\00\60 used (ENQ 05h)
\47\3E\05\60 compose:
\47\60 enter an ASCII character and scan End Selection (Appendix A)
40
MicroBar 9730 - Installation Manual
Page 41
4. Output transmission settings RS-232
ACK - activating ACK or NAK activates the ACK/NAK protocol - before reading a new bar code after transmission, the product waits until the end of the hardware/software protocols time-out - "beep after transmission" if good read ("beep before transmission" also possible - see section 7, "Operating settings") - 6 error beeps if no ACK (positive acknowledge) received from the host system before end of timeout - ENQ/ACK/NAK exclusive with XON/XOFF and RTS/CTS not used (*)
\48\3E\00\60 used (ACK 06h)
\48\3E\06\60 compose:
\48\60 enter an ASCII character and scan End Selection (Appendix A)
MicroBar 9730 - Installation Manual
41
Page 42
4. Output transmission settings RS-232
NAK - activating ACK or NAK activates the ACK/NAK protocol - a NAK (negative acknowledge) from the host system indicates an unsuccessful transmission attempt - "beep after transmission" if good read ("beep before transmission" also possible - see section 7, "Operating settings") - 6 error beeps after 3 unsuccessful transmission attempts (3 NAKs) or if no ACK (positive acknowledge) received from the host system before end of timeout - ENQ/ACK/NAK exclusive with XON/XOFF and RTS/CTS not used (*)
\49\3E\00\60 used (NAK 15h)
\49\3E\15\60 compose:
\49\60 enter an ASCII character and scan End Selection (Appendix A)
42
MicroBar 9730 - Installation Manual
Page 43
4. Output transmission settings RS-232
Typical ENQ / ACK / NAK scenarios host terminal
MicroBar host terminal
MicroBar
ENQ
ENQ message (OK)
message (not OK)
ACK (clears message)
NAK repeats message (OK)
ACK (clears message)
MicroBar 9730 - Installation Manual
43
Page 44
4. Output transmission settings RS-232
XON / XOFF software protocol - the host system controls the flow of data from the reader - XOFF (ASCII character DC3) from the host at the end of the hardware/software protocols timeout interrupts transmission - XON (ASCII character DC1) restarts the data flow - "beep after transmission" if good read ("beep before transmission" also possible - see section 7, "Operating settings") - XON/XOFF exclusive with ENQ/ACK/NAK and RTS/CTS not active (*)
\4B\60 active
\4A\60
RTS / CTS hardware protocol - MicroBar acts as a standard terminal and manages the RTS/CTS lines when configured - CTS is tested before transmission of each character - data is only transmitted when CTS is activated (high) - if CTS not used by the host system, MicroBar keeps the level high - RTS is activated (high) before data is transmitted - RTS is deactivated (low) when message transmission is completed after the specified timeout - "beep after transmission" if good read ("beep before transmission" also possible - see section 7 "Operating settings") - 6 error beeps if no response from the host system before end of timeout - RTS/CTS exclusive with ENQ/ACK/NAK and XON/XOFF not active (*)
\4D\60
44
MicroBar 9730 - Installation Manual