4. Output transmission settings

4. Output transmission settings - interface-specific parameters for communication with the host system - modify output transmission settings to optimize performance

MicroBar 9730 - Installation Manual

27

Page 28

4. Output transmission settings keyboard wedge keyboard wedge - default values (*) are for IBM PC AT and compatible - QWERTY English special keys interpretation (Code 39) - certain dual-character combinations in Code 39 bar codes can be interpreted and transmitted as special keyboard keys (Code 39 is not full ASCII and does not support direct encoding of special keyboard keys such as <Enter> and <Tab>) - only for keyboard wedge applications with Code 39 bar codes !!! (both the MicroBar and your barcode reader must be enabled to read Code 39 codes with the correct barcode length settings)

28 emulated key characters emulated key characters

DEL ENTER RETURN SEND FIELD + FIELD EXIT HOME END TAB ALT BACK TAB BACKSPACE right arrow left arrow up arrow down arrow CLEAR FIELD DUP ESC LINE FEED

.A .B .C .D .E .F .G .H .I .J .K .L .M .N .O .P .Q .R .S .T .U

PF1 PF2 PF3 PF4 PF5 PF6 PF7 PF8 PF9 PF10 PF11 PF12 PF13 PF14 PF15 PF16 PF17 PF18 PF19 PF20 PF21

0A 0B 0C 0D 0E 0F 0G 0H 0I 0J 0K 0L 0M 0N 0O 0P 0Q 0R 0S 0T 0U

MicroBar 9730 - Installation Manual

Page 29

4. Output transmission settings keyboard wedge emulated key characters emulated key characters

RESET CTRL SPECIAL

.V .W .X

PF22 PF23 PF24

0V 0W 0X not active (*)

\42\57\60 special dual-character combinations not interpreted (original code string transmitted without interpretation) Example ( . I dual-character combination = <Tab> ) original Code 39 code:

interpreted and transmitted as:

msg . Ixx .I x-.I msg - . Ixx msg . Ixx .I x-.I msg - . Ixx always active

\42\58\60 special dual-character combinations interpreted as special keys always

Example ( . I dual-character combination = <Tab> ) original Code 39 code:

interpreted and transmitted as:

msg . Ixx .I x-.I msg - . Ixx msg<Tab>xx <Tab> x <Tab> msg<Tab>xx

MicroBar 9730 - Installation Manual

29

Page 30

4. Output transmission settings keyboard wedge separate 2 character label

\42\5A\60 special dual-character combinations interpreted if only 2 characters in the original code Example ( . I dual-character combination = <Tab> ) original Code 39 code:

interpreted and transmitted as:

msg . Ixx .I x-.I msg - . Ixx msg . Ixx <Tab> x-.I msg - . Ixx separate 2 character label or preceded by a hyphen

\42\59\60 special dual-character combinations interpreted if only 2 characters in the original code or if there is a hyphen in front of the 2 characters Example ( . I dual-character combination = <Tab> )

30 original Code 39 code:

interpreted and transmitted as:

msg . Ixx .I x-.I msg - . Ixx msg . Ixx <Tab> x <Tab> msg<Tab>xx

MicroBar 9730 - Installation Manual

Page 31

4. Output transmission settings keyboard wedge control character substitution - systematically replaces a specified character by a control function sequence not active (*)

\4C\43\3E\00\60 transmits characters as they appear in the original message (<ctrl> + <character> function not activated) active on Form Feed character

\4C\43\3E\0C\60

- all Form Feed characters replaced by control function sequence compose activation character and activate: [range: 1]

\4C\43\60 enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) specifies the character used to activate a control function sequence (<specified_character> + <next_character> will be replaced by <ctrl_down> + <next_character> + <ctrl_up>) Example : if you compose <FF> (Form Feed) as the activation character, the input string 'A <FF> B C' will be transmitted as 'A <ctrl B> C'

MicroBar 9730 - Installation Manual

31

Page 32

4. Output transmission settings keyboard wedge keyboard remapping - define the characters you want to 'remap' before they are transmitted ('input character' transmitted as 'output character') - keyboard remapping is applied after data editing !!! (if applicable) - maximum number of character pairs in MicroBar = 178 reset remapping in MicroBar

\4C\46\3E\00\3E\00\60 removes all remap settings in the MicroBar (recommended before you define new remapping) define: this option only available with EasySet - define the character pairs you want to remap - each new character pair definition is added to the list already in the MicroBar - if you remap the same input character more than once, the MicroBar uses the latest remap definition (reset the remapping before you define a new set of character pairs) - maximum number of character pairs in the MicroBar = 178 - maximum length for a single setup command = 255 datastring characters or approximately 100 character pairs (send successive batches if you need more character pairs !) - keyboard remapping is editing !!! (if applicable)

32 applied after data

MicroBar 9730 - Installation Manual

Page 33

4. Output transmission settings keyboard wedge

Alt mode transmission - emulates PC AT keyboard [<Alt> + decimal_sequence] function (for bar codes containing ASCII characters not on your keyboard) off (*)

\41\47\60 on

\41\46\60

- use only if necessary as transmission is slower (all characters are transmitted as <Alt> sequences) Example "A { B" is transmitted as: <Alt> + <6> + <5> <Alt> + <1> + <2> + <3>

<Alt> + <6> + <6> inter-character delay (output to host) - avoids dropping characters if transmitting decoded data too fast for the host system none (*)

\52\00\60

10 ms

\52\0A\60

20 ms

\52\14\60

MicroBar 9730 - Installation Manual

33

Page 34

4. Output transmission settings keyboard wedge 30 ms

\52\1E\60

40 ms

\52\28\60

50 ms

\52\32\60 compose (ms): [range: 1-999 ms]

\52\60 enter a number string and scan End Selection (Appendix C)

inter-message delay (output to host) - gives the host system enough time to process each message received, especially when the host must act on end-of-message control codes such as <Enter> - "rolling buffer" operation : 1. a new inter-message delay cycle is activated each time the MicroBar receives a message 2. if the MicroBar receives a new message before the end of the inter-message delay, it stores the previous message in a "rolling buffer" memory and the cycle starts again 3. when no more messages are received before the end of an inter-message delay cycle, all the messages stored in the buffer are transmitted to the host system (First-In-First-Out, each message separated by the inter-message delay) none (*)

\53\00\60

34

MicroBar 9730 - Installation Manual

Page 35

4. Output transmission settings keyboard wedge 100 ms

\53\01\24\60

500 ms

\53\07\34\60

1000 ms (1 sec)

\53\0F\28\60

2000 ms (2 sec)

\53\1F\10\60

5000 ms (5 sec)

\53\01\0E\08\60 compose (ms): [range: 1-6000 ms]

\53\60 enter a number string and scan End Selection (Appendix C)

end-of-transmission keyboard character status - sets keyboard to lower case or upper case at end of transmission - Code 39 is transmitted in upper case - Code 128 is transmitted in lower case / upper case (full ASCII) lower case (*)

\41\44\60

MicroBar 9730 - Installation Manual

35