The text of a manual · part 10 of 25
MicroBar 9730 Decoder Installation Manual: 5. Symbologies, pages 79 to 87
Pages 79 to 87 of 200, from MicroBar 9730 Decoder Installation Manual
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9730
Page 79
5. Symbologies
5. Symbologies - symbology = bar code type or family (e.g. Code 39, UPC, EAN) - the following barcode readers can be connected to the MicroBar : - pen barcode readers - laser / CCD barcode readers in wand / laser emulation - activate the symbologies you need and modify the settings for your symbologies if required - to optimize performance, only activate symbologies you need !!! (deactivate the Code 39 and UPC/EAN default symbologies if you don't need them) - if your input device is a ScanPlus in wand / laser emulation : - activate the same symbologies and code lengths for the ScanPlus and the MicroBar - disconnect the ScanPlus to make sure that "ScanPlus transparent configuration mode" is disabled before you configure the ScanPlus disable all symbologies
\41\4B\60
- deactivates all the symbologies activated - use the "not active" options to deactivate individual symbologies - does not reset individual parameter settings for each symbology (when you reactivate a symbology, you recover the parameter settings stored in memory for that symbology when it was disabled - use reset factory defaults to reset all the symbology parameters to their factory default settings)
MicroBar 9730 - Installation Manual
79
Page 80
5. Symbologies Ames Code
Ames Code - numerical symbology not active (*)
\41\55\60 active
\41\54\60
80
MicroBar 9730 - Installation Manual
Page 81
5. Symbologies Codabar
Codabar - numerical symbology not active (*)
\41\53\60 active
\41\52\60 start/stop not transmitted (*)
\43\4D\60 a, b, c, d
\43\4E\60
A, B, C, D
\43\4F\60 a, b, c, d/ t, n, *, e
\43\50\60
DC1, DC2, DC3, DC4
\43\51\60
MicroBar 9730 - Installation Manual
81
Page 82
5. Symbologies Codabar
CLSI library system - spaces inserted after characters 1, 5, 10 in the 14-character label (used in the USA by libraries using the CLSI system) Example: " 39990000192148 " is transmitted as " 3 9990 00019 2148 " - start/stop can be transmitted or not transmitted as required not active (*)
\43\53\60 active
\43\52\60
- inserts spaces check digit (AIM recommendation) - AIM has a recommended check character for Codabar - each Codabar data character (including Start/Stop) has a value assigned to it: 0 = 01 = 1 2=2 3=3 4=4 5=5 6=6 7=7 8=8 9=9 = 11 : = 12 / = 13 , = 14 + = 15 A = 16 B = 17 C = 18 D = 19
- = 10
$
- the values are added and the check is calculated: check = [(next multiple of 16) - (sum of assigned AIM values)] Example
82 data characters:
A01234B
AIM values = 16 + 0 + 1 + 2 + 3 + 4 + 17: next multiple of 16: check = 48 - 43: final message:
43 48 5 A012345B
MicroBar 9730 - Installation Manual
Page 83
5. Symbologies Codabar not used (*)
\46\56\60 checked and transmitted
\46\54\60 checked but not transmitted
\46\55\60 concatenation - 2 adjacent Codabar codes scanned in a single sweep can be transmitted as a single message - if the scanner is configured to transmit start/stop characters, MicroBar will only transmit first start and last stop (intermediate start/stop characters not transmitted) not active
\43\56\60
- no concatenation active no start/stop restrictions (*)
\43\57\60 concatenates adjacent codes intermediate start/stop characters not transmitted
MicroBar 9730 - Installation Manual
83
Page 84
5. Symbologies Codabar stop 1 = start 2
\43\58\60
- intermediate start/stop characters not transmitted - only concatenates adjacent codes if stop character of first code = start character of second code : barcode_1 (left)
barcode_2 (right)
<start = C>....(<stop = A>)
(<start = A>)....<stop = D>
ABC (American Blood Commission)
\43\59\60 intermediate start/stop characters not transmitted ABC : only concatenates adjacent codes if stop character of first code = D and start character of second code = D : barcode_1 (left)
barcode_2 (right)
<start = A / B / C / D>....(<stop = D>)
(<start = D>)....<stop = A / B / C / D> transmit all codes (single, concatenated) (*)
\43\5A\60 concatenated codes only
\43\5B\60
84
MicroBar 9730 - Installation Manual
Page 85
5. Symbologies Code 11
Code 11 - numerical symbology not active (*)
\42\45\60 active
\42\44\60 check digits 1 digit (*)
\45\43\60
2 digits
\45\44\60 checked and transmitted (*)
\45\45\60 checked but not transmitted
\45\46\60
MicroBar 9730 - Installation Manual
85
Page 86
5. Symbologies Code 39
Code 39 - alphanumeric symbology - letter case not defined - transmitted in upper case - default format = Standard 43 Characters active (*)
\41\4C\60 not active
\41\4D\60 format standard 43 characters (*)
\42\4A\60 full ASCII
\42\4B\60
- extra characters encoded using 1 of 4 control characters ($, %, /, +) combined with a letter :
86
MicroBar 9730 - Installation Manual
Page 87
5. Symbologies Code 39
MicroBar 9730 - Installation Manual
Code 39
ASCII
Hex
Dec
%U $A $B $C $D $E $F $G $H $I $J $K $L $M $N $O $P $Q $R $S $T $U $V $W $X $Y $Z %A %B %C %D %E Space /A
NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US SP !
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
87