Page 88
5. Symbologies Code 39
88
Code 39
ASCII
Hex
Dec
/B /C $ % /F /G /H /I /J + /L /M /N / 0 1 2 3 4 5 6 7 8 9 /Z %F %G %H %I %J %V A B C
" # $ % & ' ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? @ A B C
22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 41 42 43
34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67
MicroBar 9730 - Installation Manual
Page 89
5. Symbologies Code 39
MicroBar 9730 - Installation Manual
Code 39
ASCII
Hex
Dec
D E F G H I J K L M N O P Q R S T U V W X Y Z %K %L %M %N %O %W +A +B +C +D +E
D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _ ` a b c d e
44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 45 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65
68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101
89
Page 90
5. Symbologies Code 39 Code 39
ASCII
Hex
Dec
+F +G +H +I +J +K +L +M +N +O +P +Q +R +S +T +U +V +W +X +Y +Z %P %Q %R %S %T f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL
66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 start/stop not transmitted (*)
\42\4D\60
90
MicroBar 9730 - Installation Manual
Page 91
5. Symbologies Code 39 transmitted
\42\4C\60 accepted characters " * " only (*)
\42\4E\02\60
" $ " only
\42\4E\01\60
" $ " and " * " accepted
\42\4E\03\60 check digit not used (*)
\42\4F\60 modulo 43 - provides extra validation of data checked and transmitted
\42\50\60 checked but not transmitted
\42\51\60
MicroBar 9730 - Installation Manual
91
Page 92
5. Symbologies Code 39
French CIP - French pharmaceutical industry - only used for codes with 7 characters checked and transmitted
\42\52\60 checked but not transmitted
\42\53\60
Italian CPI - Italian pharmaceutical industry - transmitted as standard Code 39 if checksum not validated checked and transmitted
\42\54\60 checked but not transmitted
\42\55\60 multiread - multiread stores a number of bar codes in the MicroBar memory before transmitting them as a single message : 1. MicroBar receives a "multiread" string (Code 39 bar code beginning with multiread indicator character) and stores it in memory 2. each new multiread string is added to the multicode message in the MicroBar memory
92
MicroBar 9730 - Installation Manual
Page 93
5. Symbologies Code 39
3. MicroBar transmits the full multicode message to the terminal or host when it receives a string which does not begin with the multiread indicator character or if the memory is full (maximum 255 characters) - the multiread indicator character is not transmitted with the message - default multiread indicator character = <space> not active (*)
\42\56\3E\00\60 active (default multiread character = space)
\42\56\00\60 compose multiread character:
\42\56\60 enter an ASCII character and scan End Selection (Appendix A)
MicroBar 9730 - Installation Manual
93
Page 94
5. Symbologies Code 93
Code 93 - alphanumeric full ASCII symbology - letter case defined not active (*)
\41\5F\60 active
\41\5E\60 multiread - multiread stores a number of bar codes in the MicroBar memory before transmitting them as a single message : 1. MicroBar receives a "multiread" string (Code 39 bar code beginning with multiread indicator character) and stores it in memory 2. each new multiread string is added to the multicode message in the MicroBar memory 3. MicroBar transmits the full multicode message to the terminal or host when it receives a string which does not begin with the multiread indicator character or if the memory is full (maximum 255 characters) - the multiread indicator character is not transmitted with the message - default multiread indicator character = <space> not active (*)
\45\40\3E\00\60 active (default multiread character = space)
\45\40\00\60
94
MicroBar 9730 - Installation Manual
Page 95
5. Symbologies Code 93 compose multiread character:
\45\40\60 enter an ASCII character and scan End Selection (Appendix A)
MicroBar 9730 - Installation Manual
95
Page 96
5. Symbologies Code 128 / EAN 128
Code 128 / EAN 128 - alphanumeric full ASCII symbology - letter case defined - "EAN 128" = Code 128 with the FNC1 character in the first position - EAN 128 is auto-discriminating with Code 128 (recognition of the FNC1 start character used) not active (*)
\41\5B\60 active
\41\5A\60
EAN 128 identifier - the ]C1 AIM identifier for EAN 128 is automatically added by default in front of EAN 128 bar codes include ]C1 identifier (*)
\47\5A\01\60 remove ]C1 identifier
\47\5A\00\60
96