Page 97
5. Symbologies Code 128 / EAN 128
CIP 128 French pharmaceutical codes - embedded CIP 39 data - fixed length 14 characters - Code 128 character set C not active (*)
\47\5D\00\60 active
\47\5D\01\60
FNC1 separator character (EAN 128 norms) - default = GS function character (ASCII 29) - used as separator when multiple identifiers and their fields are concatenated GS (ASCII 29) (*)
\46\52\3E\1D\60 compose:
\46\52\60
- enter an ASCII character and scan End Selection (Appendix A) - useful for keyboard wedge interfaces where the GS character can not be transmitted
MicroBar 9730 - Installation Manual
97
Page 98
5. Symbologies Code 128 / EAN 128
ISBT 128 concatenation not active (*)
\4A\48\00\60 transmit 2 concatenated codes
\4A\48\01\60
- only transmits if 2 codes are read before end of timeout or trigger release - does not transmit if only 1 code transmit 1 code / 2 concatenated codes
\4A\48\02\60 transmits 1 code or 2 concatenated codes if a second code is read during the next 5 scans
98
MicroBar 9730 - Installation Manual
Page 99
5. Symbologies Interleaved 2 of 5
Interleaved 2 of 5 - numerical symbology not active (*)
\41\4F\60 active
\41\4E\60 check digit - especially recommended for variable length Interleaved 2 of 5 and if "consecutive same read data validation" (data decoding security parameters) is not activated not used (*)
\43\43\60 mod 10 checked and transmitted
\42\5F\60 checked but not transmitted
\43\40\60
MicroBar 9730 - Installation Manual
99
Page 100
5. Symbologies Interleaved 2 of 5
French CIP HR - French pharmaceutical industry - only used for codes with 7 characters checked and transmitted
\43\41\60 checked but not transmitted
\43\42\60 barcode length = <barcode data> + [check digit] - minimum length possible = 2 characters - default = 1 fixed length 14 characters !!! - if the codes in your application have fixed lengths, use one of the "fixed lengths" options !!! - Interleaved 2 of 5 always encodes an even number of characters - for codes with an odd number of characters, you can add a last character printed as 5 narrow bars (not transmitted) 1 fixed length = 14 characters (*)
\43\44\0E\60
100
MicroBar 9730 - Installation Manual
Page 101
5. Symbologies Interleaved 2 of 5 compose 1 or 2 or 3 fixed lengths:
\43\44\60
- enter a number string and scan End Selection for each length and scan End Selection twice to finish (Appendix C) - defining fixed lengths provides the best performance and security if the codes in your application have fixed lengths - minimum length possible = 2 characters - all 3 lengths = "0" resets default length (14 characters) get fixed lengths from codes: [range: 1-3]
\4A\5C\60 enter a number string and scan End Selection (Appendix C) only for codes longer than 4 characters !!! (use "compose 1 or 2 or 3 fixed lengths" option for short codes) defining fixed lengths provides the best performance and security if the codes in your application have fixed lengths 1. enter the number of fixed lengths you want to define (1, 2 or 3) 2. read 1, 2 or 3 Interleaved 2 of 5 bar codes with the lengths used in your application the MicroBar will only read codes with the lengths you have defined any length
\43\45\00\60
- cancels any fixed length settings and accepts any valid length (2 or more characters)
MicroBar 9730 - Installation Manual
101
Page 102
5. Symbologies Matrix 2 of 5
Matrix 2 of 5 - numerical symbology not active (*)
\42\41\60 active
\42\40\60
102
MicroBar 9730 - Installation Manual
Page 103
5. Symbologies MSI Code
MSI Code - numerical symbology not active (*)
\41\59\60 active
\41\58\60 check digit mod 10 checked and transmitted (*)
\44\5A\60 checked but not transmitted
\44\5C\60 double mod 10 checked and transmitted
\44\5B\60 checked but not transmitted
\44\5D\60
MicroBar 9730 - Installation Manual
103
Page 104
5. Symbologies Plessey Code
Plessey Code - numerical symbology not active (*)
\41\5D\60 active
\41\5C\60 check digit not transmitted (*)
\44\57\60 transmitted
\44\56\60
104
MicroBar 9730 - Installation Manual
Page 105
5. Symbologies Standard 2 of 5
Standard 2 of 5 - numerical symbology - default format = Identicon (6 start/stop bars) - also referred to as "Straight 2 of 5" and "Industrial 2 of 5" not active (*)
\41\51\60 active
\41\50\60 format Identicon (6 start/stop bars) (*)
\43\47\60
Computer Identics (4 start/stop bars)
\43\46\60 check digit mod 10 not used (*)
\43\4A\60 checked and transmitted
\43\48\60
MicroBar 9730 - Installation Manual
105