Page 135
6. Input devices RS-232 input devices on port 4 Example ( single character 88h = <Tab> ) original message:
transmitted as:
88 msg88xx
88 msg88xx
Example ( ". I" dual-character combination = <Tab> ) original message:
transmitted as:
msg . Ixx .I x-.I msg - . Ixx msg . Ixx .I x-.I msg - . Ixx single character ASCII value > 7Fh - interpreted as special keyboard function if encountered in the original message - the RS-232 input device must have " data bits = 8 " if you want to use this option ! active
\4A\46\16\04\04\60
Example ( single character 88h = <Tab> ) original message:
transmitted as:
88 msg88xx
<Tab> msg<Tab>xx
MicroBar 9730 - Installation Manual
135
Page 136
6. Input devices RS-232 input devices on port 4 single character ASCII value > 7Fh
136 emulated key character > 7Fh emulated key character > 7Fh
DEL ENTER RETURN SEND FIELD + FIELD EXIT HOME END TAB ALT BACKTAB BACKSPACE right arrow left arrow up arrow down arrow CLEAR FIELD DUP ESC LINE FEED RESET CTRL PF24
80h 81h 82h 83h 84h 85h 86h 87h 88h 89h 8Ah 8Bh 8Ch 8Dh 8Eh 8Fh 90h 91h 92h 93h 94h 95h 96h AFh
PF1 PF2 PF3 PF4 PF5 PF6 PF7 PF8 PF9 PF10 PF11 PF12 PF13 PF14 PF15 PF16 PF17 PF18 PF19 PF20 PF21 PF22 PF23
98h 99h 9Ah 9Bh 9Ch 9Dh 9Eh 9Fh A0h A1h A2h A3h A4h A5h A6h A7h A8h A9h AAh ABh ACh ADh AEh
MicroBar 9730 - Installation Manual
Page 137
6. Input devices RS-232 input devices on port 4 dual-character combinations - interpreted as special keyboard functions (" . B " = <Enter>, " . I " = <Tab>, etc.) if encountered in the original message emulated key characters emulated key characters
DEL ENTER RETURN SEND FIELD + FIELD EXIT HOME END TAB ALT BACK TAB BACKSPACE right arrow left arrow up arrow down arrow CLEAR FIELD DUP ESC LINE FEED RESET CTRL PF24
.A .B .C .D .E .F .G .H .I .J .K .L .M .N .O .P .Q .R .S .T .U .V .W 0X
PF1 PF2 PF3 PF4 PF5 PF6 PF7 PF8 PF9 PF10 PF11 PF12 PF13 PF14 PF15 PF16 PF17 PF18 PF19 PF20 PF21 PF22 PF23
0A 0B 0C 0D 0E 0F 0G 0H 0I 0J 0K 0L 0M 0N 0O 0P 0Q 0R 0S 0T 0U 0V 0W
MicroBar 9730 - Installation Manual
137
Page 138
6. Input devices RS-232 input devices on port 4 in all messages
\4A\46\16\04\01\60 dual-character values in original message string always interpreted as special keys Example ( ". I" dual-character combination = <Tab> ) original message:
transmitted as:
msg . Ixx .I msg<Tab>xx <Tab> in 2-character messages
\4A\46\16\04\03\60 special dual-character combinations interpreted if only 2 characters in the original message Example ( ". I" dual-character combination = <Tab> ) original message:
transmitted as:
msg . Ixx .I msg . Ixx <Tab> preceded by a hyphen (-)
\4A\46\16\04\02\60 special dual-character combinations interpreted if there is a hyphen in front of the 2 characters Example ( ". I" dual-character combination = <Tab> )
138 original message:
transmitted as:
msg . Ixx x-.I msg - . Ixx msg . Ixx x <Tab> ms<Tab>xx
MicroBar 9730 - Installation Manual
Page 139
6. Input devices RS-232 input devices on port 4
UDI / CICS - special keyboard wedge applications - the MicroBar converts ASCII character FF (0Ch) to wedge character <Enter> and ASCII character DC1 (11h) to wedge character <Tab> not active (*)
\4A\46\17\04\00\60 active
\4A\46\17\04\01\60
MicroBar 9730 - Installation Manual
139
Page 140
6. Input devices RS-232 input devices on port 5
RS-232 input devices on port 5 - for data received from RS-232 TTL input devices (electronic scales, barcode readers, magstripe readers, . . .) connected to Port 5 of the MicroBar enable
\4A\46\02\05\01\60 enable communication with RS-232 TTL input devices on port 5 disable (*)
\4A\46\02\05\00\60 baud rate 300
\4A\46\03\05\00\60
600
\4A\46\03\05\01\60
1200
\4A\46\03\05\02\60
2400
\4A\46\03\05\03\60
140
MicroBar 9730 - Installation Manual
Page 141
6. Input devices RS-232 input devices on port 5 4800
\4A\46\03\05\04\60
9600 (*)
\4A\46\03\05\05\60
19200
\4A\46\03\05\06\60 data bits seven (*)
\4A\46\04\05\00\60 eight
\4A\46\04\05\01\60 parity even (*)
\4A\46\05\05\01\60 odd
\4A\46\05\05\02\60
MicroBar 9730 - Installation Manual
141
Page 142
6. Input devices RS-232 input devices on port 5 mark
\4A\46\05\05\03\60 space
\4A\46\05\05\04\60 none
\4A\46\05\05\00\60 stop bits one (*)
\4A\46\06\05\01\60 two
\4A\46\06\05\02\60
ENQ / ACK / NAK - the RS-232 input device can synchronize communication with the MicroBar : 1. the RS-232 input device sends an ENQ character (05h) to the MicroBar 2. the MicroBar answers with an ACK character (06h), even if ENQ / ACK / NAK has not been activated in the MicroBar 3. the RS-232 input device sends a message to the MicroBar (the message is terminated with the selected end-of-message character) 4. the MicroBar sends an ACK character to the RS-232 input device at the end of transmission if the message is understood, or a NAK character (15h) if the message is not understood
142
MicroBar 9730 - Installation Manual
Page 143
6. Input devices RS-232 input devices on port 5
- there is no hardware/software protocols timeout for RS-232 input devices
ENQ not active (*)
\4A\46\07\05\00\60 active (ENQ 05h)
\4A\46\07\05\01\60
ACK not active
\4A\46\09\05\00\60 active (ACK 06h) (*)
\4A\46\09\05\01\60
NAK not active
\4A\46\0B\05\00\60 active (NAK 15h) (*)
\4A\46\0B\05\01\60
MicroBar 9730 - Installation Manual
143
Page 144
6. Input devices RS-232 input devices on port 5
XON / XOFF software protocol - XON / XOFF allows the MicroBar to control the flow of data from the RS-232 input device - the MicroBar transmits XOFF (ASCII character DC3) to interrupt the reception of data - the MicroBar transmits XON (ASCII character DC1) to restart the data flow - activating XON / XOFF deactivates the RTS / CTS and ENQ / ACK / NAK protocols not active (*)
\4A\46\0D\05\00\60 active
\4A\46\0D\05\01\60
RTS/CTS hardware protocol - when RTS / CTS is activated, the MicroBar waits for an RTS from the RS-232 input device and sends a CTS when it is ready to receive data not active (*)
\4A\46\0E\05\00\60 active
\4A\46\0E\05\01\60
144
MicroBar 9730 - Installation Manual