Page 145
6. Input devices RS-232 input devices on port 5 transmission to the host system transmit on end-of-message character - the RS-232 input device transmits data message by message - by default, the MicroBar transfers the data to an input buffer (250 characters maximum) and sends the data to the host system when it receives an end-of-message character active (*)
\4A\46\0F\05\00\60 transmit on Carriage Return (0Dh) (*)
\4A\46\10\05\3E\0D\60 transmit on Carriage Return + Line Feed
\4A\46\10\05\04\02\0D\60 compose end-of-message character:
\4A\46\10\05\60
- enter an ASCII character and scan End Selection (Appendix A)
MicroBar 9730 - Installation Manual
145
Page 146
6. Input devices RS-232 input devices on port 5 transmit character by character - the MicroBar transmits each character to the host system as it is received (the characters do not go through the input buffer) - activate the RTS/CTS protocol with the input device (recommended) active
\4A\46\0F\05\01\60 transmit on timeout - the MicroBar transmits the buffered message to the host system after the specified time (if the RS-232 input device does not send an end-of-message character) - only applies if transmit on end-of-message character is active not active (*)
\4A\46\13\05\00\60 active
\4A\46\13\05\01\60 compose timeout before transmission (ms): [range: 0-5000 ms] (default = 2500 ms)
\4A\46\14\05\60 enter a number string and scan End Selection (Appendix C)
146
MicroBar 9730 - Installation Manual
Page 147
6. Input devices RS-232 input devices on port 5
ASCII control code transmission filter - the RS-232 input device may send control characters that you do not want the MicroBar to transmit to the host system (preambles and end-of-message characters for example) - the ASCII control code transmission filter removes any ASCII control characters 00h-20h received from the RS-232 input device before the data is transmitted to the host system transmit all ASCII characters (*)
\4A\46\15\05\01\60 do not transmit ASCII characters 00h-20h
\4A\46\15\05\00\60 special keys interpretation (output to keyboard wedge) - generation of special keyboard functions not available with RS-232 : - single characters with ASCII values greater than 7Fh interpreted as special keyboard functions (81h = <Enter>, 88h = <Tab>, etc.) - dual-character combinations interpreted as special keyboard functions (" . B " = <Enter>, " . I " = <Tab>, etc.) - the commands are mutually exclusive - only for keyboard wedge applications ! not active (*)
\4A\46\16\05\00\60 original message string transmitted without single-character / dual-character special keys interpretation
MicroBar 9730 - Installation Manual
147
Page 148
6. Input devices RS-232 input devices on port 5 Example ( single character 88h = <Tab> ) original message:
transmitted as:
88 msg88xx
88 msg88xx
Example ( ". I" dual-character combination = <Tab> ) original message:
transmitted as:
msg . Ixx .I x-.I msg - . Ixx msg . Ixx .I x-.I msg - . Ixx single character with ASCII value > 7Fh - interpreted as special keyboard function if encountered in the original message - the RS-232 input device must have " data bits = 8 " if you want to use this option ! - see the Installation Manual on the cd-rom for the table of ASCII values > 7Fh active
\4A\46\16\05\04\60
Example ( single character 88h = <Tab> )
148 original message:
transmitted as:
88 msg88xx
<Tab> msg<Tab>xx
MicroBar 9730 - Installation Manual
Page 149
6. Input devices RS-232 input devices on port 5 single character with ASCII value > 7Fh emulated key character > 7Fh emulated key character > 7Fh
DEL ENTER RETURN SEND FIELD + FIELD EXIT HOME END TAB ALT BACKTAB BACKSPACE right arrow left arrow up arrow down arrow CLEAR FIELD DUP ESC LINE FEED RESET CTRL PF24
80h 81h 82h 83h 84h 85h 86h 87h 88h 89h 8Ah 8Bh 8Ch 8Dh 8Eh 8Fh 90h 91h 92h 93h 94h 95h 96h AFh
PF1 PF2 PF3 PF4 PF5 PF6 PF7 PF8 PF9 PF10 PF11 PF12 PF13 PF14 PF15 PF16 PF17 PF18 PF19 PF20 PF21 PF22 PF23
98h 99h 9Ah 9Bh 9Ch 9Dh 9Eh 9Fh A0h A1h A2h A3h A4h A5h A6h A7h A8h A9h AAh ABh ACh ADh AEh
MicroBar 9730 - Installation Manual
149
Page 150
6. Input devices RS-232 input devices on port 5 dual-character combinations - interpreted as special keyboard functions (" . B " = <Enter>, " . I " = <Tab>, etc.) if encountered in the original message
150 emulated key characters emulated key characters
DEL ENTER RETURN SEND FIELD + FIELD EXIT HOME END TAB ALT BACK TAB BACKSPACE right arrow left arrow up arrow down arrow CLEAR FIELD DUP ESC LINE FEED RESET CTRL PF24
.A .B .C .D .E .F .G .H .I .J .K .L .M .N .O .P .Q .R .S .T .U .V .W 0X
PF1 PF2 PF3 PF4 PF5 PF6 PF7 PF8 PF9 PF10 PF11 PF12 PF13 PF14 PF15 PF16 PF17 PF18 PF19 PF20 PF21 PF22 PF23
0A 0B 0C 0D 0E 0F 0G 0H 0I 0J 0K 0L 0M 0N 0O 0P 0Q 0R 0S 0T 0U 0V 0W
MicroBar 9730 - Installation Manual
Page 151
6. Input devices RS-232 input devices on port 5 in all messages
\4A\46\16\05\01\60 dual-character values in original message string always interpreted as special keys Example ( ". I" dual-character combination = <Tab> ) original message:
transmitted as:
msg . Ixx .I msg<Tab>xx <Tab> in 2-character messages
\4A\46\16\05\03\60 special dual-character combinations interpreted if only 2 characters in the original message Example ( ". I" dual-character combination = <Tab> ) original message:
transmitted as:
msg . Ixx .I msg . Ixx <Tab> preceded by a hyphen (-)
\4A\46\16\05\02\60 special dual-character combinations interpreted if there is a hyphen in front of the 2 characters Example ( ". I" dual-character combination = <Tab> ) original message:
transmitted as:
msg . Ixx x-.I msg - . Ixx msg . Ixx x <Tab> ms<Tab>xx
MicroBar 9730 - Installation Manual
151
Page 152
6. Input devices RS-232 input devices on port 5
UDI / CICS - special keyboard wedge applications - the MicroBar converts ASCII character FF (0Ch) to wedge character <Enter> and ASCII character DC1 (11h) to wedge character <Tab> not active (*)
\4A\46\17\05\00\60 active
\4A\46\17\05\01\60
152
MicroBar 9730 - Installation Manual