The text of a manual · part 15 of 25
MicroBar 9730 Decoder Installation Manual: 6. Input devices, pages 125 to 134
Pages 125 to 134 of 200, from MicroBar 9730 Decoder Installation Manual
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9730
Page 125
6. Input devices scales / weighing machines - if the data editing and scale solicitation functions have an identical input scenario, data editing has priority (scale solicitation will not occur !!!)
MicroBar 9730 - Installation Manual
125
Page 126
6. Input devices RS-232 input devices on port 4
RS-232 input devices on port 4 - for data received from RS-232 C input devices (electronic scales, barcode readers, . . .) connected to Port 4 of the MicroBar - use adaptor cable 0-234032-02 to connect an RS-232 device to port 4 enable
\4A\46\02\04\01\60 enable communication with RS-232 C input devices on port 4 disable (*)
\4A\46\02\04\00\60 baud rate 300
\4A\46\03\04\00\60
600
\4A\46\03\04\01\60
1200
\4A\46\03\04\02\60
2400
\4A\46\03\04\03\60
126
MicroBar 9730 - Installation Manual
Page 127
6. Input devices RS-232 input devices on port 4 4800
\4A\46\03\04\04\60
9600 (*)
\4A\46\03\04\05\60
19200
\4A\46\03\04\06\60 data bits seven (*)
\4A\46\04\04\00\60 eight
\4A\46\04\04\01\60 parity even (*)
\4A\46\05\04\01\60 odd
\4A\46\05\04\02\60
MicroBar 9730 - Installation Manual
127
Page 128
6. Input devices RS-232 input devices on port 4 mark
\4A\46\05\04\03\60 space
\4A\46\05\04\04\60 none
\4A\46\05\04\00\60 stop bits one (*)
\4A\46\06\04\01\60 two
\4A\46\06\04\02\60
ENQ / ACK / NAK - the RS-232 input device can synchronize communication with the MicroBar : 1. the RS-232 input device sends an ENQ character (05h) to the MicroBar 2. the MicroBar answers with an ACK character (06h), even if ENQ / ACK / NAK has not been activated in the MicroBar 3. the RS-232 input device sends a message to the MicroBar (the message is terminated with the selected end-of-message character) 4. the MicroBar sends an ACK character to the RS-232 input device at the end of transmission if the message is understood, or a NAK character (15h) if the message is not understood
128
MicroBar 9730 - Installation Manual
Page 129
6. Input devices RS-232 input devices on port 4
- there is no hardware/software protocols timeout for RS-232 input devices
ENQ not active (*)
\4A\46\07\04\00\60 active (ENQ 05h)
\4A\46\07\04\01\60
ACK not active
\4A\46\09\04\00\60 active (ACK 06h) (*)
\4A\46\09\04\01\60
NAK not active
\4A\46\0B\04\00\60 active (NAK 15h) (*)
\4A\46\0B\04\01\60
MicroBar 9730 - Installation Manual
129
Page 130
6. Input devices RS-232 input devices on port 4
Typical ENQ / ACK / NAK scenarios RS-232 input device
MicroBar
RS-232 input device
MicroBar
ENQ
ENQ
ACK
ACK message (OK)
message (not OK)
ACK (clears message)
NAK repeats message (OK)
ACK (clears message)
130
MicroBar 9730 - Installation Manual
Page 131
6. Input devices RS-232 input devices on port 4
XON / XOFF software protocol - XON / XOFF allows the MicroBar to control the flow of data from the RS-232 input device - the MicroBar transmits XOFF (ASCII character DC3) to interrupt the reception of data - the MicroBar transmits XON (ASCII character DC1) to restart the data flow - activating XON / XOFF deactivates the RTS / CTS and ENQ / ACK / NAK protocols not active (*)
\4A\46\0D\04\00\60 active
\4A\46\0D\04\01\60
RTS/CTS hardware protocol - when RTS / CTS is activated, the MicroBar waits for an RTS from the RS-232 input device and sends a CTS when it is ready to receive data not active (*)
\4A\46\0E\04\00\60 active
\4A\46\0E\04\01\60
MicroBar 9730 - Installation Manual
131
Page 132
6. Input devices RS-232 input devices on port 4 transmission to the host system transmit on end-of-message character - the RS-232 input device transmits data message by message - by default, the MicroBar transfers the data to an input buffer (250 characters maximum) and sends the data to the host system when it receives an end-of-message character active (*)
\4A\46\0F\04\00\60 transmit on Carriage Return (0Dh) (*)
\4A\46\10\04\3E\0D\60 transmit on Carriage Return + Line Feed
\4A\46\10\04\04\02\0D\60 compose end-of-message character:
\4A\46\10\04\60
- enter an ASCII character and scan End Selection (Appendix A)
132
MicroBar 9730 - Installation Manual
Page 133
6. Input devices RS-232 input devices on port 4 transmit character by character - the MicroBar transmits each character to the host system as it is received (the characters do not go through the input buffer) - activate the RTS/CTS protocol with the input device (recommended) active
\4A\46\0F\04\01\60 transmit on timeout - the MicroBar transmits the buffered message to the host system after the specified time (if the RS-232 input device does not send an end-of-message character) - only applies if transmit on end-of-message character is active not active (*)
\4A\46\13\04\00\60 active
\4A\46\13\04\01\60 compose timeout before transmission (ms): [range: 0-5000 ms]
(default = 2500 ms)
\4A\46\14\04\60 enter a number string and scan End Selection (Appendix C)
MicroBar 9730 - Installation Manual
133
Page 134
6. Input devices RS-232 input devices on port 4
ASCII control code transmission filter - the RS-232 input device may send control characters that you do not want the MicroBar to transmit to the host system (preambles and end-of-message characters for example) - the ASCII control code transmission filter removes any ASCII control characters 00h-20h received from the RS-232 input device before the data is transmitted to the host system transmit all ASCII characters (*)
\4A\46\15\04\01\60 do not transmit ASCII characters 00h-20h
\4A\46\15\04\00\60 special keys interpretation (output to keyboard wedge) - generation of special keyboard functions not available with RS-232 : - single characters with ASCII values greater than 7Fh interpreted as special keyboard functions (81h = <Enter>, 88h = <Tab>, etc.) - dual-character combinations interpreted as special keyboard functions (" . B " = <Enter>, " . I " = <Tab>, etc.) - the commands are mutually exclusive - only for keyboard wedge applications ! not active (*)
\4A\46\16\04\00\60 original message string transmitted without single-character / dual-character special keys interpretation
134
MicroBar 9730 - Installation Manual